Shopping Cart

No products in the cart.

ASTM-C1685:2008 Edition

$35.75

C1685-08 Standard Specification for Pneumatically Applied High-Temperature Fiber Thermal Insulation for Industrial Applications

Published By Publication Date Number of Pages
ASTM 2008 4
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM C1685-08

Historical Standard: Standard Specification for Pneumatically Applied High-Temperature Fiber Thermal Insulation for Industrial Applications

ASTM C1685

Scope

1.1 This specification covers the composition, thermal performance, and physical properties of high-temperature fiber thermal insulation for use at temperatures from ambient to 3000Ā°F (1649Ā°C).

1.2 The dry, loose high-temperature fibers shall be pneumatically conveyed to a nozzle where they are mixed with a water-based chemical binder.

1.3 The pneumatically applied, high-temperature fiber insulation is intended for use in industrial applications on flat, or nearly flat, surfaces. It is not intended for use on pipes.

1.4 This specification does not address the requirements for fire-resistive insulation, but it does not preclude this materialā€™s use in that capacity.

1.5 This is a material specification only and is not intended to cover methods of application that are provided by the manufacturer.

1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

cured; high-temperature fiber insulation; industrial applications; pneumatically applied; refractory fibers

ICS Code

ICS Number Code 27.220 (Heat recovery. Thermal insulation)

DOI: 10.1520/C1685-08

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Materials and Manufacture
Physical Properties
TABLE 1
3 Workmanship, Finish and Appearance
Sampling
Specimen Preparation
Test Methods
Qualification Requirements
Inspection and Acceptance of Installed Insulation
Acceptance or Rejection
4 Packaging and Package Marking
Delivery and Storage
Installation
Keywords
ASTM-C1685