Shopping Cart

No products in the cart.

BS EN 15091:2024

$198.66

Sanitary tapware. Electronic opening and closing sanitary tapware

Published By Publication Date Number of Pages
BSI 2024 56
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The purpose of this document is to specify requirements for marking, identification, leaktightness, electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing controlled electronically. The conditions of use for the supply system type are specified in Table 2: [Table 2] Annex B lists possible consequences of using a product outside its recommended operating range. [Figure 1] [Figure 2]

PDF Catalog

PDF Pages PDF Title
2 undefined
9 1 Scope
12 2 Normative references
13 3 Terms and definitions
4 General requirements and testing
4.1 Marking
4.2 Identification
4.3 Materials
4.3.1 Chemical and hygienic requirements
4.3.2 Exposed surface conditions
14 4.4 Functions
4.5 Backflow protection
4.6 Electric characteristics and requirements
4.6.1 General
4.6.2 Electrical safety
15 4.6.3 Electrical operation of solenoid valves
4.6.3.1 Marking
4.6.3.2 Voltage
4.6.4 Electric strength and insulation resistance of the solenoid valve
4.6.5 Operational safety
4.6.5.1 Test procedure for mains operated tapware
4.6.5.2 Requirements for mains operated tapware
4.6.5.3 Test procedure for battery operated tapware
16 4.6.5.4 Requirements for battery operated tapware
4.7 Leaktightness characteristics
4.7.1 General
4.7.2 Principle
4.7.3 Apparatus
4.7.4 Leaktightness of tapware upstream of the obturator
4.7.4.1 Procedure
4.7.4.2 Requirements
4.7.5 Leaktightness of tapware downstream of the obturator with the obturator open
4.7.5.1 General
17 4.7.5.2 Procedure
4.7.5.3 Requirements
4.7.6 Leaktightness tests – Summary table
4.8 Pressure resistance characteristics – mechanical performance under pressure
4.8.1 General
4.8.2 Principle
4.8.3 Apparatus
4.8.4 Procedure
18 4.8.5 Requirements
5 Requirements and testing for tapware
5.1 General
5.2 Dimensional characteristics
5.2.1 General
5.2.2 Tap with visible body for horizontal surfaces
20 5.2.3 Taps with visible body for mounting on vertical surfaces
5.2.4 In-line tapware with threaded inlet and outlet
5.2.4.1 Inlets and outlets aligned
21 5.2.4.2 Inlets and outlets at right angles
5.2.5 Concealed tapware for vertical surfaces
5.2.6 Mixing valves for horizontal surface
5.2.6.1 General
22 5.2.6.2 Supply by tube
23 5.2.7 Mixing valves with visible body for mounting on vertical surfaces with captive nuts and eccentric unions
5.2.8 Mixing valves with opposed inlets
24 5.2.9 Nozzle outlets for use with aerators with integrated flow regulators
5.2.10 Special cases
25 5.3 Hydraulic characteristics
5.3.1 General
5.3.2 Test apparatus for tapware intended for Type 1 water supply systems
5.3.2.1 General
5.3.2.2 Supply circuits type 1
26 5.3.2.3 Test circuit Type 1
28 5.3.2.4 Pressure take-off tees
5.3.2.5 Mounting of single taps intended for Type 1 water supply systems
5.3.2.6 Mounting of mixing valves intended for Type 1 water supply systems
29 5.3.2.7 Test apparatus for tapware intended for Type 2 supply systems
5.3.3 Principle of the flow test
30 5.3.4 Requirements
5.3.5 Cross flow between hot and cold water
5.3.5.1 Principle
5.3.5.2 Procedure
5.3.5.3 Requirements
5.4 Water hammer
5.4.1 Principle of water hammer test
5.4.2 Test apparatus
31 5.4.3 Procedure
32 5.4.4 Requirements
5.5 Endurance
5.5.1 General
5.5.2 Principle
5.5.3 Procedure for single taps
5.5.4 Procedure for mixers
5.5.4.1 General
33 5.5.4.2 Testing of opening and closing element
5.5.4.3 Testing of temperature mixing valves
5.5.5 Requirements
5.6 Acoustic characteristics
5.6.1 General
5.6.2 Procedure
5.6.2.1 Mounting and operating conditions for tapware
5.6.2.2 Test method
34 5.6.3 Requirements
5.6.3.1 Expression of results
5.6.3.2 Determination of the acoustic group
5.6.3.3 Flow classes
35 6 Requirements and testing for flushing valves for urinals
6.1 General
6.2 Definitions
6.2.1 Single flush urinal valves
6.2.2 Siphon action flushing urinal valves
6.2.3 Isolating valves for flushing urinal valves
6.3 Classification of flushing urinal valves
6.4 Designation
36 6.5 Dimensional characteristics
37 6.6 Hydraulic characteristics
6.6.1 General
6.6.2 Test method
6.6.2.1 Test apparatus
6.6.2.2 Test methodology
6.6.2.3 Requirements
6.7 Measurement of water hammer for urinal flushing valves
6.7.1 Principle of water hammer test
38 6.7.2 Test apparatus
6.7.2.1 General
6.7.2.2 Procedure of choice of pipe sizing
6.7.3 Procedure
6.7.4 Requirements
39 6.8 Mechanical endurance
6.8.1 General
6.8.2 Apparatus
6.8.3 Procedure
6.8.4 Requirements
7 Requirements and testing for flushing valves for WCs
7.1 General
40 7.2 Definitions
7.3 Classification
7.3.1 General
41 7.4 Dimensional characteristics
42 7.5 Hydraulic characteristics
7.5.1 General
7.5.2 Test method
7.5.2.1 General
43 7.5.2.2 Principle
44 7.5.2.3 Procedure for flow rate/impact force test
7.5.2.4 Procedure for flow rate/volume test
7.5.2.5 Test apparatus
7.5.2.6 Impact force measuring instrument
45 7.5.2.7 Definitions
46 7.5.3 Testing of the flow rate/impact force at lower dynamic pressure
7.5.3.1 Procedure
7.5.3.2 Requirements for flush flow rate impact force for valves DN15 and DN 20
7.5.3.3 Requirements for flush flow rate/impact force for valves DN 25 and DN 32
47 7.5.4 Testing of the flow rate/Volume at lower dynamic pressure
7.5.4.1 Procedure
7.5.4.2 Requirements for WC flushing valve DN15 and DN20
7.5.4.3 Requirements for WC flushing valves DN 25 and DN 32
48 7.5.5 Testing of flush flow rate/impact force at upper dynamic pressure
7.5.5.1 Procedure
7.5.5.2 Requirements for WC flushing valves DN 15 and DN 20
7.5.5.3 Requirements for WC flushing valves DN 25 and DN 32
50 7.5.6 Measurement of water hammer
7.5.6.1 Procedure
7.5.6.2 Requirements
7.6 Principle and verification of atmospheric pipe interrupters of WC flushing valves
7.7 Mechanical endurance
7.7.1 General
7.7.2 Procedure
7.7.3 Minimum requirements
7.8 Acoustic characteristics
51 Annex A (normative)Design of pressure take-off tees
53 Annex B (informative)Potential consequences of use outside the recommended operating limits
54 Annex C (informative)Minimum flow rates and test pressures according to application
BS EN 15091:2024
$198.66