BS EN 16755:2017:2022 Edition
$142.49
Durability of reaction to fire performance. Classes of fire-retardant treated wood products in interior and exterior end use applications
Published By | Publication Date | Number of Pages |
BSI | 2022 | 28 |
This European Standard describes the characteristics for fire-retardant treated wood products.
NOTE 1 It is based on maintaining performance undiminished throughout the desired service life in the anticipated conditions of use.
The European Standard prescribes the classification requirements for the durability of the reaction to fire performance of fire-retardant treated wood products to be used in interior and exterior end use conditions.
This European Standard applies to wood which has been treated during a production process with fire retardant products applied either by a penetration process or by a superficial process, such as with a film forming or intumescent fire retardant coating. It covers fire-retardant treated products that are coated with an ordinary paint.
Mechanical properties and biological durability of fire-retardant treated wood products are not covered by this European Standard.
NOTE 2 This standard can be used for other manufactured wood products.
This standard covers wood products. It doesnāt cover wood-based panels.
NOTE 3 Wood based panels for construction are described in EN 13986.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
5 | European foreword |
6 | Introduction |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
8 | 4 Symbols and abbreviations 5 Requirements 5.1 Wood products and non-fire-retardant coating systems |
9 | 5.2 Reaction to fire performance 5.2.1 Initial classification for reaction to fire 5.2.2 Reaction to fire performance before and after accelerated or natural weathering |
10 | 5.3 Durability of reaction to fire performance 5.3.1 General 5.3.2 DRF Class INT1 5.3.3 DRF Class INT2 5.3.4 DRF Class EXT |
11 | 5.3.5 Practise to use DRF classes |
12 | 6 Classification report |
13 | Annex A (normative) Hygroscopic properties of fire-retardant treated wood products including those with fire-retardant coatings |
18 | Annex B (normative) Accelerated weathering of fire-retardant treated wood for fire testing |
22 | Annex C (informative) Example of classification report ā Classification report: Durability classes of reaction to fire performance of fire-retardant wood products in interior and exterior end use applications according to EN 16755:2017 |
26 | Bibliography |