BS EN 61869-3:2011:2012 Edition
$167.15
Instrument transformers – Additional requirements for inductive voltage transformers
Published By | Publication Date | Number of Pages |
BSI | 2012 | 34 |
This part of IEC 61869 applies to new inductive voltage transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz.
NOTE 301 Requirements specific to three-phase voltage transformers are not included in this standard but, so far as they are relevant, the requirements in clauses 4 to 10 apply to these transformers and a few references to them are included in those clauses (e.g. see 3.1.303, 5.301.1, 5.301.2, 5.5.301, 6.13.301.1 and Table 304).
All the transformers shall be suitable for measuring purposes, but, in addition, certain types may be suitable for protection purposes. Transformers for the dual purpose of measurement and protection shall comply with all clauses of this standard.
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | English CONTENTS |
10 | 1 Scope 2 Normative references 3 Terms, definitions and abbreviations 3.1 General definitions |
11 | 3.2 Definitions related to dielectric ratings |
12 | 3.4 Definitions related to accuracy 3.5 Definitions related to other ratings 3.7 Index of abbreviations |
13 | 5 Ratings 5.3 Rated insulation levels 5.5 Rated output |
14 | 5.6 Rated accuracy class Tables Table 301 ā Limits of voltage error and phase displacement formeasuring voltage transformers |
15 | Table 302 ā Limits of voltage error and phase displacementfor protective voltage transformers |
16 | 5.301 Standard values of rated voltages |
17 | 5.302 Standard values of rated voltage factor Table 303 ā Rated voltages for secondary windings intendedto produce a residual voltage |
18 | 6 Design and construction 6.4 Requirements for temperature rise of parts and components 6.13 Markings |
19 | Figures Figure 301 ā Single-phase transformerwith fully insulated terminalsand a single secondary Figure 302 ā Single-phase transformerwith a neutral primary terminal withreduced insulation and a single secondary Figure 303 ā Three-phase assembly with a single secondary |
20 | Figure 304 ā Single-phase transformerwith two secondaries Figure 305 ā Three-phase assemblywith two secondaries Figure 306 ā Single-phase transformerwith one multi-tap secondary Figure 307 ā Three-phase assembly withone multi-tap secondary |
21 | Figure 308 ā Single-phase transformer with two multi-tap secondaries Figure 309 ā Single-phase transformer withone residual voltage winding Figure 310 ā Three-phase transformer withone residual voltage winding |
23 | 6.301 Short-circuit withstand capability 7 Tests 7.1 General Figure 311 ā Example of a typical rating plate Figure 312 ā Example of a rating plate with typical data |
24 | 7.2 Type tests Table 10 ā List of tests |
26 | Table 305 ā Burden ranges for accuracy tests |
27 | 7.3 Routine tests |
29 | Figure 313 ā Common mode (separate source) test voltage application Figure 314 ā Differential mode (induced) test voltage application ā Primary excitation |
30 | 7.4 Special tests Figure 315 ā Differential mode (induced) test voltage application ā Secondary excitation |