BS EN ISO 18563-1:2022
$198.66
Non-destructive testing. Characterization and verification of ultrasonic phased array equipment – Instruments
Published By | Publication Date | Number of Pages |
BSI | 2022 | 56 |
This document specifies the functional characteristics of multi-channel ultrasonic phased array instruments used for array probes and provides methods for their measurement and verification. This document is also applicable to ultrasonic phased array instruments in automated systems; but other tests can be needed to ensure satisfactory performance. When the phased array instrument is a part of an automated system, the acceptance criteria can be modified by agreement between the parties involved. This document also can partly be applicable to FMC instruments and TFM instruments. This document gives the extent of the verification and defines acceptance criteria within a frequency range of 0,5 MHz to 10 MHz.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | European foreword Endorsement notice |
7 | Foreword |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Symbols and abbreviated terms |
12 | 5 General requirements of conformity 6 Manufacturer’s technical specification for ultrasonic phased array instruments |
16 | 7 Performance requirements for ultrasonic phased array instruments |
18 | 8 Group 1 tests 8.1 Equipment required for group 1 tests |
19 | 8.2 Battery operational time 8.2.1 General 8.2.2 Procedure |
20 | 8.2.3 Acceptance criterion 8.3 Stability after warm-up time 8.3.1 Procedure |
22 | 8.3.2 Acceptance criteria 8.4 Stability against temperature 8.4.1 Procedure 8.4.2 Acceptance criteria |
23 | 8.5 Stability against voltage variations 8.5.1 Procedure 8.5.2 Acceptance criteria 8.6 Deviation of time base 8.6.1 General 8.6.2 Procedure |
25 | 8.6.3 Acceptance criterion 8.7 Transmitter 8.7.1 General 8.7.2 Pulse repetition frequency 8.7.3 Effective output impedance |
26 | 8.7.4 Resolution of time delay |
27 | 8.8 Receiver 8.8.1 General 8.8.2 Cross-talk attenuation between receivers |
28 | 8.8.3 Dead time after the transmitter pulse |
30 | 8.8.4 Dynamic range and maximum input voltage |
32 | 8.8.5 Receiver input impedance 8.8.6 Time-corrected gain (TCG) |
33 | 8.8.7 Resolution of time delay |
34 | 8.8.8 Linearity of vertical display against frequency 8.8.9 Summation |
35 | 8.9 Gates 8.9.1 General |
36 | 8.9.2 Linearity of gate amplitude |
37 | 8.9.3 Linearity of time-of-flight in the gate |
38 | 8.9.4 Monitor gates with analogue outputs |
40 | 8.10 Highest digitized frequency 8.10.1 Procedures |
42 | 8.10.2 Acceptance criterion 8.11 Response time of ultrasonic phased array instrument 8.11.1 General 8.11.2 Procedure |
44 | 8.11.3 Acceptance criterion 9 Group 2 tests 9.1 Equipment required for group 2 tests 9.2 Physical state and external aspects 9.2.1 Procedure 9.2.2 Acceptance criteria 9.3 Transmitter 9.3.1 General 9.3.2 Transmitter pulse voltage, rise time and duration |
47 | 9.3.3 Linearity of time delays 9.4 Receiver 9.4.1 General 9.4.2 Frequency response |
49 | 9.4.3 Equivalent input noise |
50 | 9.4.4 Linearity of gain |
51 | 9.4.5 Variation of channel gain |
52 | 9.4.6 Linearity of vertical display |
53 | 9.4.7 Linearity of time delay |
55 | Bibliography |