New IEEE Standard – Active. This standard covers metal-enclosed switchgear assemblies incorporating gas insulating systems containing, but not limited to, such devices as interrupter switches; selector switches; fuses; circuit breakers; control, instrumentation and metering devices; and protective equipment. It includes, but is not specifically limited to, equipment for the control and protection of apparatus used for distribution of electrical power.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.20.9™-2019 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
9 | Introduction |
12 | Contents |
15 | IMPORTANT NOTICE 1. Scope 2. Normative references |
19 | 3. Definitions |
23 | 4. Normal (usual) and special (unusual) service conditions 4.1 Normal (usual) service conditions |
24 | 4.2 Special (unusual) service conditions for both indoor and outdoor switchgear |
25 | 5. Ratings 5.1 General |
26 | 5.2 Rated maximum voltage (V) or (Ur) 5.3 Rated insulation level (Ud, Up) |
27 | 5.4 Rated power frequency (fr) 5.5 Rated continuous (normal) current and temperature rise |
30 | 5.6 Rated short-time withstand current (Ik) 5.7 Rated peak withstand current (Ip) |
31 | 5.8 Rated duration of short-time withstand current (tk) 5.9 Rated supply voltage of closing and opening devices and of auxiliary and control circuits (Ua) 5.10 Rated supply frequency of closing and opening devices and of auxiliary circuits 5.11 Rated pressure of compressed gas for insulation and/or operation 5.12 Current transformer ratings |
33 | 6. Design and construction 6.1 Buses, primary connections, and other components |
35 | 6.2 Grounding |
36 | 6.3 Control and secondary circuits and devices |
40 | 6.4 Miscellaneous |
41 | 6.5 Materials and finish |
42 | 6.6 Precautionary labels |
43 | 6.7 Barriers 6.8 Interlocks |
44 | 6.9 Enclosure categories 6.10 Circuit breaker or switch—open/close position indication 6.11 Degrees of protection provided by enclosures 6.12 Requirements for gases in switchgear |
45 | 6.13 Requirements for gas tightness |
46 | 6.14 Requirements for gas compartments 6.15 Remote test cabinet 6.16 X-ray emission |
47 | 7. Design (type) tests 7.1 General |
49 | 7.2 Dielectric tests |
55 | 7.3 Radio influence voltage (RIV) test 7.4 Measurement of resistance of circuits |
56 | 7.5 Continuous current (temperature-rise) tests |
59 | 7.6 Short-time withstand current and peak withstand current tests |
61 | 7.7 Enclosure categories and related requirements 7.8 Tightness tests |
62 | 7.9 Electromagnetic compatibility tests 7.10 Additional tests on auxiliary and control circuit 7.11 X-Radiation procedure for vacuum interrupters |
63 | 7.12 Mechanical tests |
64 | 7.13 Insulating, isolating, and sealing materials |
68 | 7.14 Coatings qualification test |
69 | 7.15 Weatherproofing test for outdoor MEGIS 8. Production (routine) tests 8.1 General 8.2 Dielectric test on the main circuit |
70 | 8.3 Inspection and dielectric test on auxiliary and control circuits 8.4 Measurement of the resistance of the main circuit |
71 | 8.5 Tightness test 8.6 Design and visual checks 8.7 Mechanical operation tests 8.8 Camera tests 9. Field dielectric tests |
72 | 10. Application guide for MEGIS 10.1 Special (unusual) service conditions |
76 | 10.2 System characteristics—voltage and frequency 10.3 Overvoltage considerations—insulation levels 10.4 Continuous current rating and overload capability |
77 | 10.5 Short-circuit considerations 10.6 Nuclear power plant application 10.7 Exposed circuits 10.8 Surge arresters in switchgear assemblies 10.9 Protection and isolation of switchgear connected to other switching equipment |
78 | 10.10 Current transformer accuracies 10.11 Replacement materials and parts 11. Guide for handling, storage, and installation (informative) 11.1 Handling |
80 | 11.2 Preoperation check |
81 | 11.3 Mechanical tests—leakage 11.4 Mechanical tests—gas quality (moisture, purity, and density) |
82 | 11.5 Energization |
83 | Annex A (normative) Guide for enclosure categories and related requirements A.1 Scope A.2 Enclosure categories |
84 | A.3 Enclosure requirements |
90 | Annex B (normative) Flame-resistance tests for applied insulation (exposed to air) B.1 Test apparatus |
91 | B.2 Preparation of sample B.3 Test procedure |
92 | B.4 Analysis |
93 | Annex C (normative) Partial discharge testing C.1 General C.2 Test circuits and measuring systems C.3 Calibration of measuring system and calibrators C.4 Tests |
94 | C.5 Test procedure C.6 Maximum permissible partial discharge magnitude |
96 | Annex D (normative) Voltage dividers D.1 Introduction D.2 Glossary A.1 Construction |
97 | D.4 Performance |
99 | Annex E (normative) Conformance testing E.1 Test and retest schedules |
100 | E.2 Insulating material changes E.3 Tests for internal arcing faults (optional) |
101 | Annex F (normative) Evaluation of changes made in insulating materials and systems F.1 Overview F.2 Related standards |
102 | F.3 Definitions |
103 | F.4 Requirements for compliance |
107 | F.5 Tests |
108 | F.6 Replacement of gas |
109 | Annex G (normative) Identification of test specimens G.1 Data G.2 Drawings |
111 | Annex H (informative) Exposure to pollution H.1 General H.2 Pollution levels H.3 Minimum requirements for MEGIS |
113 | Annex I (normative) Method for the weatherproofing test for outdoor switchgear |
116 | Annex J (informative) Partition classes for MEGIS |
117 | Annex K (informative) Bibliography |
120 | Back cover |