17.120.20 – Flow in open channels – PDF Standards Store ?u= Wed, 06 Nov 2024 01:34:50 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 17.120.20 – Flow in open channels – PDF Standards Store ?u= 32 32 ISO/TS 3716:2006 ?u=/product/publishers/iso/iso-ts-37162006/ Wed, 06 Nov 2024 01:34:50 +0000 Hydrometry — Functional requirements and characteristics of suspended-sediment samplers
Published By Publication Date Number of Pages
ISO 2006-08 18
]]>
ISO/TS 3716:2006 specifies the functional requirements and characteristics of the different types of suspended-sediment samplers.

]]>
ISO/TS 25377:2007 ?u=/product/publishers/iso/iso-ts-253772007/ Wed, 06 Nov 2024 01:34:11 +0000 Hydrometric uncertainty guidance (HUG)
Published By Publication Date Number of Pages
ISO 2007-10 58
]]>
ISO/TS 25377:2007 provides an understanding of the nature of measurement uncertainty and its significance in estimating the quality of a measurement or a determination in hydrometry. It is applicable to flow measurements in natural and man-made channels. Rainfall measurements are not covered.

]]>
ISO/TS 24155:2007 ?u=/product/publishers/iso/iso-ts-241552007/ Wed, 06 Nov 2024 01:33:50 +0000 Hydrometry — Hydrometric data transmission systems — Specification of system requirements
Published By Publication Date Number of Pages
ISO 2007-05 42
]]>
ISO/TS 24155:2007 specifies the technical requirements that should be considered in designing and operating hydrometric data transmission systems and the necessary functions of those systems.

]]>
ISO/TS 24154:2005 ?u=/product/publishers/iso/iso-ts-241542005/ Wed, 06 Nov 2024 01:33:50 +0000 Hydrometry — Measuring river velocity and discharge with acoustic Doppler profilers
Published By Publication Date Number of Pages
ISO 2005-11 16
]]>
ISO/TS 24154:2005 gives the principles of operation, construction, maintenance and application of acoustic Doppler profilers to the measurement of velocity and discharge, and discusses calibration and verification issues. It is applicable to open-channel flow measurements with an instrument mounted on a moving vessel.

ISO/TS 24154:2005 is not applicable to measurement of liquid flow in small channels or partly-filled pipes using a single Doppler-based flowmeter at a fixed point in the cross section.

]]>
ISO/TS 15769:2000 ?u=/product/publishers/iso/iso-ts-157692000/ Wed, 06 Nov 2024 01:27:04 +0000 Hydrometric determinations — Liquid flow in open channels and partly filled pipes — Guidelines for the application of Doppler-based flow measurements
Published By Publication Date Number of Pages
ISO 2000-12 30
]]>
Hydrometric determinations — Liquid flow in open channels and partly filled pipes — Guidelines for the application of Doppler-based flow measurements
Published By Publication Date Number of Pages
ISO 2000-12 30
]]>
ISO/TS 15768:2000 ?u=/product/publishers/iso/iso-ts-157682000/ Wed, 06 Nov 2024 01:27:03 +0000 Measurement of liquid velocity in open channels — Design, selection and use of electromagnetic current meters
Published By Publication Date Number of Pages
ISO 2000-07 16
]]>
This Technical Specification gives guidelines for the design, selection and use of electromagnetic current meters

used to determine point velocity for the purpose of measuring flow in an open channel using the velocity area

method.

NOTE The electromagnetic current meter is acceptable as a device for making point determinations of velocity for the

purposes of open channel flow determination by the velocity area method, using the multiple point velocity sampling technique

described in ISO 748 (see reference [1] in the Bibliography).

]]>
ISO/TR 9823:1990 ?u=/product/publishers/iso/iso-tr-98231990/ Wed, 06 Nov 2024 01:19:59 +0000 Liquid flow measurement in open channels — Velocity-area method using a restricted number of verticals
Published By Publication Date Number of Pages
ISO 1990-08 13
]]>
Liquid flow measurement in open channels — Velocity-area method using a restricted number of verticals
Published By Publication Date Number of Pages
ISO 1990-08 13
]]>
ISO/TR 9212:2015 ?u=/product/publishers/iso/iso-tr-92122015/ Wed, 06 Nov 2024 01:19:36 +0000 Hydrometry — Methods of measurement of bedload discharge
Published By Publication Date Number of Pages
ISO 2015-06 32
]]>
ISO/TR 9212:2015 reviews the current status of direct and indirect bedload-measurement techniques. The methods are mainly based on grain size distribution of the bedload, channel width, depth, and velocity of flow. This Technical Report outlines and explains several methods for direct and indirect measurement of bedload in streams, including various types of sampling devices.

The purposes of measuring bedload-transport rates are to

a) increase the accuracy of estimating total sediment load in rivers and deposition in reservoirs,

b) gain knowledge of bedload transport that cannot be completely measured by conventional suspended-sediment collection methods,

c) provide data to calibrate or verify theoretical transport models, and

d) provide information needed in the design of river diversion and entrainment structures.

NOTE The units of measurement used in this Technical Report are SI units.

]]>
ISO/TR 9210:2017 ?u=/product/publishers/iso/iso-tr-92102017/ Wed, 06 Nov 2024 01:19:35 +0000 Hydrometry — Measurement in meandering river and in streams with unstable boundaries
Published By Publication Date Number of Pages
ISO 2017-11 14
]]>
ISO/TR 9210:2017 provides guidelines for discharge measurements in meandering and braided rivers, and from bridges, following the provisions of ISO 748.

]]>
ISO/TR 9210:1992 ?u=/product/publishers/iso/iso-tr-92101992/ Wed, 06 Nov 2024 01:19:34 +0000 Measurement of liquid flow in open channels — Measurement in meandering rivers and in streams with unstable boundaries
Published By Publication Date Number of Pages
ISO 1992-06 9
]]>
Provides guidelines for discharge measurements (especially for site selection) in meandering and braided rivers, and from bridges, following the provisions of ISO 748.

]]>