{"id":265391,"date":"2024-10-19T17:42:12","date_gmt":"2024-10-19T17:42:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-172062020\/"},"modified":"2024-10-25T13:39:25","modified_gmt":"2024-10-25T13:39:25","slug":"bs-en-172062020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-172062020\/","title":{"rendered":"BS EN 17206:2020"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3 Terms and definitions 3.1 General terms <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 3.2 Loads, forces and pressures <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 3.3 Electrical equipment and control systems <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 3.4 Tolerances relating to movement 4 Hazards 4.1 General <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 4.2 List of Significant Hazards <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5 Design requirements 5.1 General <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 5.2 Examples of machine installations showing the groups <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 5.3 Load assumptions for stage elevators <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 5.4 Load bearing equipment 5.4.1 General 5.4.2 Load bearing lines 5.4.2.1 Wire ropes 5.4.2.2 Chains 5.4.3 Load bearing lines terminations 5.4.3.1 Wire rope terminations <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 5.4.3.2 Detachable wire rope terminations <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 5.4.3.3 Fixed or Non-detachable wire rope terminations 5.4.3.4 Load Hooks 5.4.3.5 End connections for steel chains <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 5.5 Winding devices and diverter pulleys 5.5.1 Winding devices for wire ropes 5.5.2 Diverter pulleys for round wire ropes 5.5.3 Drive and idler sprockets for steel chains <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 5.6 Drive systems 5.6.1 General <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 5.6.2 Screw jack systems (spindle drives) 5.6.3 Hydraulic systems <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 5.6.4 Auxiliary drive systems 5.6.5 Manual systems 5.7 Load carrying devices <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 6 Safeguarding hazardous areas 6.1 Protective spaces for inspection and maintenance 6.2 Accessibility of maintenance areas <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 6.3 Safeguarding at crushing, shearing and trapping points, and fall protection 6.4 Elevator shaft walls, openings and landing doors 6.4.1 General 6.4.2 Interlocking of doors 6.5 Counterweights <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 7 Electrical equipment and control systems 7.1 General requirements 7.1.1 General <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 7.1.2 Selection of equipment 7.1.3 Physical environment and operation conditions 7.1.3.1 Electromagnetic compatibility (EMC) <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 7.1.3.2 Ambient air temperature and humidity 7.2 Incoming supply conductor terminations and devices for disconnecting and switching off 7.2.1 Electric motors and associated equipment 7.2.2 Protection against electric shock 7.2.3 Protection of equipment 7.2.3.1 General <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 7.2.3.2 Protection under fault conditions 7.2.3.3 Cutting off power 7.2.4 Control circuits and control functions 7.2.4.1 General 7.2.4.2 Control devices 7.2.4.3 Enabling devices <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 7.2.4.4 Cable-less control devices 7.2.5 Travel of groups of machines 7.2.5.1 General 7.2.5.2 Travel of several groups 7.3 Safety functions and control functions in the event of failure 7.3.1 General <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 7.3.2 Providing redundancy 7.3.3 Hazardous operating conditions <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 7.3.4 Safety devices and safety functions 7.3.4.1 General 7.3.4.2 Limitation of travel <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 7.3.4.3 Providing protection when characteristic loads are exceeded (Overload Protection) 7.3.4.4 Providing protection in underload or slack conditions 7.3.4.5 Providing protection against improper winding 7.3.4.6 Providing protection when wear limits of screw jacks are reached 7.3.4.7 Providing protection when speed regulators fail 7.3.4.8 Providing protection against over-speed conditions 7.3.4.9 Providing protection against brake failure 7.3.4.10 Protection against power source failure <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 7.3.4.11 Protection against structural overload 7.3.4.12 Providing protection against drive transmission failure 7.3.4.13 Providing protection against crushing and shearing 7.3.4.14 Prevention of hazardous collision with other machines 7.3.4.15 Protection against incorrect positions of machines <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 7.3.4.16 Protection against moving into open pit areas 7.3.4.17 Protection against creating a hazardous zone 7.3.4.18 Protection against dangerous door access 7.3.4.19 Protection against loss of group synchronisation 7.3.5 Means for testing safety devices and safety functions 7.3.5.1 General <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 7.3.5.2 Muting (override) of safety functions 7.4 Emergency stop functions 7.4.1 Emergency stop 7.4.2 Actuators for and design of emergency stop functions 7.5 Complementary Protective Measures 7.5.1 General <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 7.5.2 Limitation of number of simultaneous moving machines 7.5.3 Protection against unplanned load deviations (load profile monitoring) 7.6 Electronic and programmable electronic systems (E\/PES) 7.6.1 General 7.6.2 Programmable controllers 7.6.3 Use of programmable electronic systems (E\/E\/PES) to implement safety functions 7.7 Use of electronic and programmable electronic systems (E\/PES) without safety functions 7.8 Operator interfaces, control devices and contactors 7.8.1 General 7.8.2 Requirements for contactors <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 7.9 Marking, warning signs and reference designations 7.10 Testing and validation of electrical systems 7.10.1 General 7.10.2 Scope of routine testing 7.11 Validation and verification of functional safety systems <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 8 Documentation 8.1 General 8.2 Technical data to be included 8.2.1 General 8.2.2 User information for safety functions <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 8.3 Marking 8.3.1 General 8.3.2 Entertainment load limit <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 8.3.3 Supplementary loading information 8.3.4 Machinery <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 8.3.5 Remote operation 8.4 Documentation and information 8.4.1 General 8.4.2 Operating manual 8.4.2.1 General 8.4.2.2 Description <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 8.4.2.3 Instruction book reference 8.4.2.4 Use 8.4.2.5 Operator qualification 8.4.2.6 Control 8.4.2.7 Vigilance <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 8.4.2.8 Special requirements 8.4.3 Installation Instructions 8.4.3.1 General 8.4.3.2 Handling 8.4.3.3 Mounting details 8.4.3.4 Installation 8.4.3.5 Commissioning 8.4.3.6 Installation load testing 8.4.4 Repair and maintenance instructions 8.4.4.1 General <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 8.4.4.2 Repairs, adjustment, lubrication and replacements 8.4.4.3 Repairs, adjustments and replacement of safety related components 8.4.5 Inspection and examination 8.4.6 Dismantling instructions 8.4.6.1 General 8.4.6.2 Access 8.4.6.3 Sequence of operations 8.4.6.4 Protection 8.4.7 Appendix to instructions (for additional necessary documents) 8.4.7.1 General <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 8.4.7.2 Wiring diagrams 8.4.7.3 Drawings and diagrams 8.4.7.4 Optional items 8.4.7.5 Test certificates 9 Testing prior to first use and after substantial changes 9.1 General 9.2 Test log 9.3 Testing prior to first use 9.3.1 Type, extent and performance of tests 9.3.1.1 General 9.3.1.2 Preliminary test <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 9.3.1.3 Structural (construction) test 9.3.2 Acceptance test 9.3.2.1 General comments 9.3.2.2 Acceptance test for safety equipment <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 9.3.2.3 Load test of lifting equipment <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 9.3.2.4 Load test of travelling and turning equipment (particularly stage wagons and revolving stages) 9.3.2.5 Testing of electrical protection measures 9.3.2.6 Acceptance report and test log 9.3.2.7 Verification following rectification of defects 9.4 Test after changes and modifications 9.4.1 Substantial Changes 9.4.2 Any other changes <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Annex A (normative)Examples of hazards and risk origin <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Annex B (normative)Use case definitions B.1 General B.2 Upper machinery <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | B.3 Lower stage machinery \u2013 lifting <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | B.4 Lower stage machinery \u2013 horizontal movement <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Annex C (informative)Recommended safety functions and measures C.1 General C.2 Upper machinery <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | C.3 Lower machinery \u2013 lifting <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | C.4 Lower machinery \u2013 horizontal movement <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Annex D (normative)End user information table to be supplied by the manufacturer <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | Annex E (informative)Designing safeguards on the basis of risk assessment E.1 General E.2 Risk assessment as in EN 62061 E.2.1 General <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | E.2.2 Guidance for selecting parameters Se, Fr and Pr for the risk estimation E.2.2.1 Severity of injury (Se) <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | E.2.2.2 Probability of occurrence of harm E.2.2.3 Frequency and duration of exposure (Fr) E.2.2.4 Probability of occurrence of a hazardous event <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | E.2.2.5 Probability of avoiding or limiting harm (Av) E.2.2.6 SIL assignment <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | E.3 Risk assessment as in EN ISO 138491 E.3.1 General E.3.2 Guidance for selecting parameters S, F and P for the risk estimation E.3.2.1 Severity of injury S1 and S2 E.3.2.2 Frequency and\/or exposure times to hazard, F1 and F2 E.3.2.3 Possibility of avoiding the hazard P1 and P2 <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | Annex F (informative)Examples of using the risk graphs F.1 Guidance for risk evaluation values for control system functions F.2 Severity <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | F.3 Possibility of avoiding the hazardous event F.4 Possibility frequency and duration of exposure <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | F.5 Probability of occurrence of a hazardous event <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | Annex G (informative)Application examples G.1 General G.2 Chain hoist for a speaker cluster \u2013 Stop on \u201cdeadman release\u201d <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | G.2.2 Use Case identification \u2013 Annex B G.2.3 Hazard definition \u2013 Annex A G.2.4 Safety function allocation \u2013 Annex C <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | G.2.5 Initial risk estimation \u2013 Annex F G.2.6 Safety function estimation \u2013 Annex E G.3 Broadcast studio lighting hoist \u2013 Protection against overload <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | G.3.2 Use Case identification \u2013 Annex B G.3.3 Hazard definition \u2013 Annex A G.3.4 Safety function allocation \u2013 Annex C <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | G.3.5 Initial risk estimation \u2013 Annex F G.3.6 Safety function estimation \u2013 Annex E G.4 Group of winches lifting a common load \u2013 protection against loss of group synchronisation <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | G.4.2 Use Case identification \u2013 Annex B G.4.3 Hazard definition \u2013 Annex A G.4.4 Safety function allocation \u2013 Annex C G.4.5 Initial risk estimation \u2013 Annex F <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | G.4.6 Safety function estimation \u2013 Annex E G.5 Chain hoist to fly a performer \u2013 protection against over-speed <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | G.5.2 Use Case identification \u2013 Annex B G.5.3 Hazard definition \u2013 Annex A G.5.4 Safety function allocation \u2013 Annex C G.5.5 Initial risk estimation \u2013 Annex F <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | G.5.6 Safety function estimation \u2013 Annex E G.6 Two winches to fly a performer \u2013 Protection against position deviation G.6.2 Use Case identification \u2013 Annex B <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | G.6.3 Hazard definition \u2013 Annex A G.6.4 Safety function allocation \u2013 Annex C G.6.5 Initial risk estimation \u2013 Annex F G.6.6 Safety function estimation \u2013 Annex E <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | G.7 Orchestra pit elevator \u2013 Protection against crushing\/shearing G.7.2 Use Case identification \u2013 Annex B G.7.3 Hazard definition \u2013 Annex A <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | G.7.4 Safety function allocation \u2013 Annex C G.7.5 Initial risk estimation \u2013 Annex F G.7.6 Safety function estimation \u2013 Annex E G.8 Stage elevator platform \u2013 Protection against overload <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | G.8.2 Use Case identification \u2013 Annex B G.8.3 Hazard definition \u2013 Annex A G.8.4 Safety function allocation \u2013 Annex C G.8.5 Initial risk estimation \u2013 Annex F <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | G.8.6 Safety function estimation \u2013 Annex E <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Entertainment technology. Machinery for stages and other production areas. Safety requirements and inspections<\/b><\/p>\n |