{"id":356591,"date":"2024-10-20T01:13:06","date_gmt":"2024-10-20T01:13:06","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-11843-62013\/"},"modified":"2024-10-26T01:36:55","modified_gmt":"2024-10-26T01:36:55","slug":"bs-iso-11843-62013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-11843-62013\/","title":{"rendered":"BS ISO 11843-6:2013"},"content":{"rendered":"

This part of ISO 11843<\/span> <\/span> presents methods for determining the critical value of the response variable and the minimum detectable value in Poisson distribution measurements. It is applicable when variations in both the background noise and the signal are describable by the Poisson distribution. The conventional approximation is used to approximate the Poisson distribution by the normal distribution consistent with ISO 11843\u20113<\/span> <\/span> and ISO 11843\u20114<\/span> <\/span>.<\/p>\n

The accuracy of the normal approximation as compared to the exact Poisson distribution is discussed in Annex C<\/span>.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nIntroduction <\/td>\n<\/tr>\n
9<\/td>\nSection sec_1
Section sec_2
Section sec_3
Section sec_4
1\tScope
2\tNormative references
3\tTerms and definitions
4\tMeasurement system and data handling <\/td>\n<\/tr>\n
10<\/td>\nSection sec_5
Section sec_5.1
5\tComputation by approximation
5.1\tThe critical value based on the normal distribution <\/td>\n<\/tr>\n
11<\/td>\nTable tab_b
Figure fig_1 <\/td>\n<\/tr>\n
12<\/td>\nSection sec_5.2
Section sec_5.3
5.2\tDetermination of the critical value of the response variable
5.3\tSufficient capability of the detection criterion <\/td>\n<\/tr>\n
13<\/td>\nSection sec_5.4
5.4\tConfirmation of the sufficient capability of detection criterion <\/td>\n<\/tr>\n
14<\/td>\nSection sec_6
Section sec_7
6\tReporting the results from an assessment of the capability of detection
7\tReporting the results from an application of the method <\/td>\n<\/tr>\n
15<\/td>\nAnnex sec_A
Annex\u00a0A
\n(informative)<\/p>\n

Symbols used in ISO\u00a011843-6 <\/td>\n<\/tr>\n

17<\/td>\nAnnex sec_B
Annex\u00a0B
\n(informative)<\/p>\n

Estimating the mean value and variance when the Poisson distribution is approximated by the normal distribution <\/td>\n<\/tr>\n

18<\/td>\nAnnex sec_C
Annex\u00a0C
\n(informative)<\/p>\n

An accuracy of approximations <\/td>\n<\/tr>\n

19<\/td>\nTable tab_C.1 <\/td>\n<\/tr>\n
20<\/td>\nTable tab_C.1___1 <\/td>\n<\/tr>\n
21<\/td>\nTable tab_h
Figure fig_C.1 <\/td>\n<\/tr>\n
22<\/td>\nAnnex sec_D
Table tab_i
Figure fig_D.1
Annex\u00a0D
\n(informative)<\/p>\n

Selecting the number of channels for the detector <\/td>\n<\/tr>\n

23<\/td>\nAnnex sec_E
Annex sec_E.1
Annex\u00a0E
\n(informative)<\/p>\n

Examples of calculations <\/td>\n<\/tr>\n

24<\/td>\nTable tab_j
Figure fig_E.1
Annex sec_E.1.1
Annex sec_E.1.2 <\/td>\n<\/tr>\n
25<\/td>\nAnnex sec_E.2 <\/td>\n<\/tr>\n
26<\/td>\nTable tab_E.1
Table tab_k
Figure fig_E.2
Annex sec_E.2.1 <\/td>\n<\/tr>\n
27<\/td>\nAnnex sec_E.2.2 <\/td>\n<\/tr>\n
28<\/td>\nReference ref_1
Reference ref_2
Reference ref_3
Reference ref_4
Reference ref_5
Reference ref_6
Reference ref_7
Reference ref_8
Reference ref_9
Reference ref_10
Reference ref_11
Reference ref_12
Reference ref_13
Reference ref_14
Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Capability of detection – Methodology for the determination of the critical value and the minimum detectable value in Poisson distributed measurements by normal approximations<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2015<\/td>\n32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":356599,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[97,2641],"product_tag":[],"class_list":{"0":"post-356591","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-03-120-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/356591","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/356599"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=356591"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=356591"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=356591"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}