{"id":375199,"date":"2024-10-20T02:42:26","date_gmt":"2024-10-20T02:42:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-21806-152021\/"},"modified":"2024-10-26T04:44:03","modified_gmt":"2024-10-26T04:44:03","slug":"bs-iso-21806-152021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-21806-152021\/","title":{"rendered":"BS ISO 21806-15:2021"},"content":{"rendered":"

This document specifies the conformance test plan (CTP) for the lean application layer for MOST, a synchronous time-division-multiplexing network, as specified in ISO 21806-14<\/span><\/span>.<\/p>\n

This document specifies conformance test cases (CTCs) for root nodes and remote nodes in the following categories:<\/p>\n

    \n
  1. \n

    network startup;<\/p>\n<\/li>\n

  2. \n

    network shutdown;<\/p>\n<\/li>\n

  3. \n

    network events;<\/p>\n<\/li>\n

  4. \n

    node discovery;<\/p>\n<\/li>\n

  5. \n

    connection management.<\/p>\n<\/li>\n<\/ol>\n

    Interoperability testing is not in the scope of this document.<\/p>\n

    PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
    PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
    2<\/td>\nNational foreword <\/td>\n<\/tr>\n
    6<\/td>\nForeword <\/td>\n<\/tr>\n
    7<\/td>\nIntroduction <\/td>\n<\/tr>\n
    11<\/td>\n1 Scope
    2 Normative references
    3 Terms and definitions <\/td>\n<\/tr>\n
    12<\/td>\n4 Symbols and abbreviated terms
    4.1 Symbols
    4.2 Abbreviated terms
    5 Conventions
    6 Conformance test plan (CTP) overview
    6.1 Test set-up <\/td>\n<\/tr>\n
    13<\/td>\n6.2 Conformance test plan organization
    7 Conformance test plan (CTP) general information
    7.1 Timer naming <\/td>\n<\/tr>\n
    14<\/td>\n7.2 Deadlock prevention
    7.3 Addresses of nodes in the lower tester
    7.4 Device manufacturer information list
    7.5 States of the node that contains the IUT <\/td>\n<\/tr>\n
    15<\/td>\n7.6 Violation of prerequisites of the CTC
    8 CTC specification for root nodes
    8.1 CTC_15.1-1 \u2013 Network startup test for root node
    8.2 CTC_15.2-1 \u2013 Network shutdown test for root node <\/td>\n<\/tr>\n
    16<\/td>\n8.3 CTC_15.3-1 \u2013 Unlock robustness test for root node <\/td>\n<\/tr>\n
    17<\/td>\n8.4 CTC_15.4-1 \u2013 Critical unlock test for root node
    8.5 CTC_15.5-1 \u2013 SSO test for root node <\/td>\n<\/tr>\n
    18<\/td>\n8.6 CTC_15.6-1 \u2013 Valid signature test for root node <\/td>\n<\/tr>\n
    19<\/td>\n8.7 CTC_15.7-1 \u2013 Unknown signature test for root node <\/td>\n<\/tr>\n
    20<\/td>\n8.8 CTC_15.8-1 \u2013 NCE test for root node <\/td>\n<\/tr>\n
    21<\/td>\n8.9 CTC_15.9-1 \u2013 Timer tHello test for root node
    8.10 CTC_15.10-1 \u2013 Duplicate signature test for root node <\/td>\n<\/tr>\n
    22<\/td>\n8.11 CTC_15.11-1 \u2013 Remote node reset test for root node <\/td>\n<\/tr>\n
    23<\/td>\n8.12 CTC_15.12-1 \u2013 Connection management test for root node <\/td>\n<\/tr>\n
    24<\/td>\n8.13 CTC_15.13-1 \u2013 Welcome_Error reaction test for root node <\/td>\n<\/tr>\n
    25<\/td>\n9 CTC specification for remote nodes
    9.1 CTC_15.1-2 \u2013 Network startup test for remote node <\/td>\n<\/tr>\n
    26<\/td>\n9.2 CTC_15.2-2 \u2013 Network shutdown test for remote node
    9.3 CTC_15.3-2 \u2013 Unlock robustness test for remote node <\/td>\n<\/tr>\n
    27<\/td>\n9.4 CTC_15.4-2 \u2013 Critical unlock test for remote node
    9.5 CTC_15.5-2 \u2013 SSO test for remote node <\/td>\n<\/tr>\n
    28<\/td>\n9.6 CTC_15.6-2 \u2013 Valid signature test for remote node <\/td>\n<\/tr>\n
    29<\/td>\n9.7 CTC_15.7-2 \u2013 Hello_Get ignore test for remote node <\/td>\n<\/tr>\n
    30<\/td>\n9.8 CTC_15.8-2 \u2013 Unchanged node position address test for remote node <\/td>\n<\/tr>\n
    31<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

    Road vehicles. Media Oriented Systems Transport (MOST) – Lean application layer conformance test plan<\/b><\/p>\n\n\n\n\n
    Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
    BSI<\/b><\/a><\/td>\n2021<\/td>\n32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":375203,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[742,2641],"product_tag":[],"class_list":{"0":"post-375199","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-43-040-15","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/375199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/375203"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=375199"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=375199"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=375199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}