{"id":420060,"date":"2024-10-20T06:29:06","date_gmt":"2024-10-20T06:29:06","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-625492011-2\/"},"modified":"2024-10-26T12:07:29","modified_gmt":"2024-10-26T12:07:29","slug":"bs-en-625492011-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-625492011-2\/","title":{"rendered":"BS EN 62549:2011"},"content":{"rendered":"

This International Standard specifies requirements and tests for systems with adaptable linear geometry for cable guiding intended for the accommodation and retention of cables and possibly other electrical equipment in electrical and\/or communi cation systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c.<\/p>\n

This standard does not apply to cable trunking systems, cable ducting systems, conduit systems, cable tray systems, cable ladder systems, powertrack systems, energy conveying chains or equipment covered by other standards.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
7<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
9<\/td>\nFOREWORD <\/td>\n<\/tr>\n
11<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
12<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
14<\/td>\n4 General requirements
5 General conditions for tests <\/td>\n<\/tr>\n
15<\/td>\n6 Classification
6.1 According to temperatures as given in Table 1 and Table 2
6.2 According to resistance to impact
Tables
Table 1 \u2013 Minimum application temperature
Table 2 \u2013 Maximum application temperature <\/td>\n<\/tr>\n
16<\/td>\n6.3 According to the installation onfloor
6.4 According to electrical continuity characteristic
6.5 According to degrees of protection, if any, provided by the system according to IEC\u00a060529:1989
7 Marking and documentation <\/td>\n<\/tr>\n
17<\/td>\n8 Dimensions
9 Construction
9.1 Sharp edges
9.2 Minimum bending radius <\/td>\n<\/tr>\n
18<\/td>\n9.3 Cable retention
9.4 Protection against ingress of solid foreign objects <\/td>\n<\/tr>\n
19<\/td>\n9.5 Protection against ingress of water
9.6 Protection against access to hazardous parts
9.7 Relieve terminals from strain
Table 3 \u2013 Torque values for screwed connections <\/td>\n<\/tr>\n
20<\/td>\n9.8 Apparatus mounting
Table 4 \u2013 Forces and torques to be applied to cable anchorage <\/td>\n<\/tr>\n
21<\/td>\n9.9 Reliable connection to earth for accessible conductive parts
9.10 Electrically protective separation
9.11 Inlet openings
9.12 Mechanical connections <\/td>\n<\/tr>\n
22<\/td>\n10 Mechanical properties
10.1 Mechanical strength
10.2 Impact test <\/td>\n<\/tr>\n
24<\/td>\n10.3 External load test for apparatus mounting
10.4 External load test <\/td>\n<\/tr>\n
26<\/td>\n11 Electrical properties
11.1 Electrical continuity <\/td>\n<\/tr>\n
27<\/td>\n11.2 Void
12 Fire hazard
12.1 Contribution to fire <\/td>\n<\/tr>\n
28<\/td>\n12.2 Void
13 External influences
13.1 Degree of protection provided by enclosure <\/td>\n<\/tr>\n
29<\/td>\n14 Electromagnetic compatibility
Figures
Figure 1 \u2013 Example of articulated system for cable guiding <\/td>\n<\/tr>\n
30<\/td>\nFigure 2 \u2013 Examples of flexible system for cable guiding <\/td>\n<\/tr>\n
34<\/td>\nFigure 3 \u2013 Examples of application of systems for cable guiding
Figure 4 \u2013 Minimum bending radius measurement <\/td>\n<\/tr>\n
35<\/td>\nFigure 5 \u2013 Examples of arrangements for cable retention tests <\/td>\n<\/tr>\n
36<\/td>\nFigure 6 \u2013 Typical apparatus for testing the resistance of cable anchorage to pull force <\/td>\n<\/tr>\n
37<\/td>\nFigure 7 \u2013 Typical apparatus for testing the resistance of cable anchorage to twist force <\/td>\n<\/tr>\n
39<\/td>\nFigure 8 \u2013 Examples of arrangement for impact test <\/td>\n<\/tr>\n
41<\/td>\nFigure 9 \u2013 Examples of arrangement for axial load test <\/td>\n<\/tr>\n
42<\/td>\nFigure 10 \u2013 Arrangement for compression test <\/td>\n<\/tr>\n
43<\/td>\nAnnex A (normative) Summary of requirements to be applied to boxes <\/td>\n<\/tr>\n
44<\/td>\nAnnex B (normative) IK code <\/td>\n<\/tr>\n
45<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Articulated systems and flexible systems for cable guiding<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2012<\/td>\n48<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":420070,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[507,2641],"product_tag":[],"class_list":{"0":"post-420060","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-120-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/420060","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/420070"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=420060"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=420060"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=420060"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}