{"id":417217,"date":"2024-10-20T06:14:55","date_gmt":"2024-10-20T06:14:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60317-502012-2\/"},"modified":"2024-10-26T11:37:28","modified_gmt":"2024-10-26T11:37:28","slug":"bs-en-60317-502012-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60317-502012-2\/","title":{"rendered":"BS EN 60317-50:2012"},"content":{"rendered":"
This part of IEC 60317 specifies the requirements of glass-fibre wound resin or varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 200. The impregnating agent is silicone resin based.<\/p>\n
\nNOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 6<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 7<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 8<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions, general notes and appearance
3.1 Terms and definitions
3.2 General notes
3.2.1 Methods of test
3.2.2 Winding wire <\/td>\n<\/tr>\n\n 9<\/td>\n 3.3 Appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
Table 1 \u2013 Elongation for wires impregnated with silicone resins <\/td>\n<\/tr>\n\n 10<\/td>\n 8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor <\/td>\n<\/tr>\n\n 11<\/td>\n 20 Resistance to hydrolysis and to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging <\/td>\n<\/tr>\n\n 12<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Specifications for particular types of winding wires – Glass-fibre wound silicone resin or varnish impregnated, bare or enamelled round copper wire, temperature index 200<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2012<\/td>\n 14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":417223,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[492,2641],"product_tag":[],"class_list":{"0":"post-417217","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-060-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/417217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/417223"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=417217"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=417217"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=417217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}