Shopping Cart

No products in the cart.

ASME A112.19.2 wAddenda a 2013

$98.04

ASME A112.19.2 Vitreous China Plumbing Fixtures and Hydraulic Requirements for Water Closets and Urinals

Published By Publication Date Number of Pages
ASME 2013 86
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Standard establishes requirements and test methods pertaining to materials, significant dimensions, and functional performance for vitreous china plumbing fixtures. The sanitary performance requirements and test procedures apply to all types of water closets and urinals that discharge into gravity waste systems in permanent buildings and structures, independent of occupancy. Fixtures referenced in this Standard include water closets, lavatories, urinals, bidets, service sinks, drinking fountains, and institutional application fixtures.

PDF Catalog

PDF Pages PDF Title
3 Update No. 1
13 Contents
18 Committee Rosters
23 Preface
25 0 Introduction
1 Scope
26 2 Reference publications
27 3 Definitions and abbreviations
3.1 Definitions
31 3.2 Abbreviations
4 General requirements
4.1 Dimensions and tolerances
4.1.1 Thickness
4.1.2 Tolerances
4.2 Glazing
32 4.3 Waste fitting openings, drainage, and overflows
4.3.1 Openings and drainage
4.3.2 Overflows
33 4.4 Off-the-floor plumbing fixture supports
4.5 Non-vitreous china plumbing fixtures
4.5.1 Glazing
4.5.2 Integral traps
4.6 Additional requirements for water closets
4.6.1 Outlet dimensions
4.6.2 Non-standard outlets
4.6.3 Bolt hole spacing
4.6.4 Roughing-in details
4.6.5 Seat-mounting holes
4.6.6 Rim profiles
4.6.7 Water surface dimensions
4.6.8 Trap diameter
34 4.6.9 Spuds
4.6.10 Rim heights
4.7 Additional requirements for urinals
4.7.1 Integral trap diameter
4.7.2 Dimensions
4.7.3 Spuds
4.7.4 Materials and construction
4.7.5 Non-water-consuming urinals
4.8 Additional requirements for lavatories, sinks, and bidets
4.8.1 Openings and mounting surfaces for supply fittings
35 4.8.2 Wall-mounted commercial lavatories and sinks
4.8.3 Spuds for clinic sinks
4.9 Additional requirements for bathtubs and shower bases
4.9.1 Minimum dimensions for bathtubs
4.9.2 Slope to the waste outlet
4.9.3 Flanges
4.10 Additional requirements for drinking fountains
4.10.1
4.10.2
4.11 Accessible design fixtures
36 5 Flushing devices used with fixtures
5.1 General
5.2 Gravity flush tanks
5.2.1 General
5.2.2 Fill valve opening diameter and location
5.2.3 Critical level
5.2.4 Low-profile gravity tanks
5.2.5 Water closet fill valve
5.2.6 Water closet tank capacity
5.3 Pressurized flushing devices
5.3.1 General
37 5.3.2 Low-profile tanks with pressurized flushing devices
5.4 Plastic water closet tanks
5.5 Electrical components of electro-hydraulic water closets
5.5.1 Pump motor and impeller
5.5.2 Jet hose
5.5.3 Electrical supply cords
5.5.4 Wiring harnesses and electrical controls
5.6 Dual-flush water closets
6 Tests — Materials, finishes, structural integrity, and seals
6.1 Water absorption test
6.1.1 Test specimen
38 6.1.2 Specimen preparation
6.1.3 Procedure
6.1.4 Report
6.1.5 Performance
6.2 Crazing test
6.2.1 Test specimen
6.2.2 Procedure
6.2.3 Performance
39 6.3 Surface examination
6.3.1 Procedure
6.3.2 Evaluation
6.3.3 Performance
6.3.4 Other fixtures
6.4 Warpage test
6.4.1 Procedure
40 6.4.2 Performance
6.5 Field-installed tiling-flange seal test
6.5.1 Procedure
6.5.2 Performance
6.6 Overflow test
6.6.1 Procedure
6.6.2 Performance
6.7 Structural integrity tests for wall-mounted plumbing fixtures
6.7.1 All wall-mounted fixtures
41 6.7.2 Wall-mounted water closets
6.7.3 Wall-mounted lavatories
6.7.4 Wall-mounted urinals
6.8 Structural integrity test for bathtubs, shower bases, andnon-vitreous service sinks
6.8.1 Apparatus
6.8.2 Procedure
42 6.8.3 Performance
6.9 Joint seal test
6.10 Auger test
6.10.1 Procedure
6.10.2 Performance
6.11 Condensation-free (insulated) tank test
6.11.1 Procedure
6.11.2 Performance
7 Water closet tests
7.1 General
7.1.1 All tests
43 7.1.2 Gravity flush tank water closets
7.1.3 Flushometer tank, electro-hydraulic, or other pressurized flushing device water closets
7.1.4 Flushometer valve water closets
7.1.5 Procedures for standardizing the water supply system
44 7.1.6 Test medium
7.1.7 Reports
7.2 Trap seal depth determination test
7.2.1 Apparatus
7.2.2 Procedure
7.2.3 Report
7.2.4 Performance
45 7.3 Trap seal restoration test
7.3.1 Apparatus
7.3.2 Procedure
7.3.3 Report
7.3.4 Performance
7.4 Water consumption test
7.4.1 General
7.4.2 Apparatus
7.4.3 Procedure
46 7.4.4 Report
7.4.5 Performance
7.5 Granule and ball test
7.5.1 Test media
7.5.2 Procedure
7.5.3 Report
7.5.4 Performance
47 7.6 Surface wash test
7.6.1 Test medium
7.6.2 Procedure
7.6.3 Report
7.6.4 Performance
7.7 Mixed media test
7.7.1 Test media
7.7.2 Procedure
48 7.7.3 Report
7.7.4 Performance
7.8 Drain line transport characterization test
7.8.1 Test medium
7.8.2 Apparatus
7.8.3 Procedure
49 7.8.4 Report
7.8.5 Performance
7.9 Overflow test for gravity flush tanks
7.9.1 Apparatus
7.9.2 Procedure
7.9.3 Report
7.9.4 Performance
7.10 Waste extraction test
7.10.1 Apparatus
50 7.10.2 Test media
51 7.10.3 Procedure
7.10.4 Report
7.10.5 Performance
7.11 Consistent water level test
7.11.1 Procedure
7.11.2 Performance
52 7.12 Fill valve shutoff integrity test with increased water pressure
7.12.1 Procedure
7.12.2 Performance
7.13 Adjustability test for tank-type gravity water closets with original equipment
7.13.1 Procedure
7.13.2 Report
7.13.3 Performance
53 7.14 Adjustability test for tank-type gravity water closets withaftermarket closure seals
7.14.1 Procedure
7.14.2 Report
7.14.3 Performance
54 8 Urinal tests
8.1 General
8.2 Test apparatus and general instructions
55 8.3 Trap seal depth determination test
8.3.1 Apparatus
8.3.2 Procedure
8.3.3 Report
8.3.4 Performance
8.4 Surface wash test
8.4.1 Test medium
8.4.2 Procedure
8.4.3 Report
56 8.4.4 Performance
8.5 Dye test
8.5.1 Test medium and apparatus
8.5.2 Procedure
8.5.3 Report
8.5.4 Performance
8.6 Water consumption test
8.6.1 Apparatus
8.6.2 Procedure
57 8.6.3 Report
8.6.4 Performance
8.7 Tests for non-water-consuming urinals
9 Markings, packaging, and installation instructions and other literature
9.1 General
9.2 Non-standard fixtures
58 9.3 Additional markings for water closets and urinals
9.3.1 Close-coupled water closets
9.3.2 Water consumption
9.3.3 Water level mark in gravity flush tank water closets
9.3.4 Water closet tank repair parts
9.4 Field-installed flanges
9.5 Packaging
9.5.1 General
59 9.5.2 Water closets and urinals
9.6 Installation instructions and other literature
9.6.1 General
9.6.2 Water closets
9.6.3 Urinals
9.6.4 Field-installed flange kits
Tables
Table 1 Permitted defects in water closets and urinals
60 Table 2 Permitted defects in lavatories and drinking fountains
Table 3 Integral trap diameter requirements for urinals, mm (in)
61 Table 4 Minimum dimensions for urinals, mm (in)
62 Table 5 Static test pressures for water closets, kPa (psi)
63 Table 6 Static test pressures for urinals, kPa (psi)
64 Figures
Figure 1 Waste outlet dimensions
65 Figure 2 Outlet dimensions for floor-mounted bottom-outlet water closets
66 Figure 3 Outlet dimensions for rear-outlet andrear-spigot-outlet water closet bowls
67 Figure 4 Bolt hole spacing for wall-mounted water closet bowls
68 Figure 5 Roughing-in and seat bolt hole dimensions for water closets
70 Figure 6 Water closet bowl rim profiles
71 Figure 7 Supply fitting opening and mounting surface dimensions
73 Figure 8 Dimensions for bathtubs
74 Figure 9 Clearance for drinking fountains
Figure 10 Gravity flush tank valve openings
75 Figure 11 Standardization of water supply system for testing gravity and flushometer tank water closets
76 Figure 12 Standardization of water supply system for testing flushometer valve water closets and urinals
77 Figure 13 Suggested apparatus and required measurements for the trap seal depth determination test
78 Figure 14 Suggested drain line transport characterization test assembly
79 Annex A (informative) Suggested formats for reporting test results
84 Annex B (informative) Unit conversion criteria
ASME A112.19.2 wAddenda a 2013
$98.04