Shopping Cart

No products in the cart.

ASTM-A773 2009

$40.63

A773/A773M-01(2009) Standard Test Method for dc Magnetic Properties of Materials Using Ring and Permeameter Procedures with dc Electronic Hysteresigraphs

Published By Publication Date Number of Pages
ASTM 2009 10
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method provides dc hysteresigraph procedures ( B-H loop methods) for the determination of basic magnetic properties of materials in the form of ring, toroidal, link, double-lapped Epstein cores, or other standard shapes that may be cut, stamped, machined, or ground from cast, compacted, sintered, forged, or rolled materials. It includes tests for normal induction and hysteresis taken under conditions of continuous sweep magnetization. Rate of sweep may be varied, either manually or automatically at different portions of the curves during tracing. Total elapsed time for tracing a hysteresis loop is commonly 10 to 120 s per loop.

1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Summary of Test Method
2 Significance and Use
Interferences
FIG. 1
3 FIG. 2
TABLE 1
4 Apparatus
Test Specimens for Ring-Type Measurements
Test Specimens for Permeameter Measurements
5 Calibration of Integrator(s)
Calibration of Magnetizing Circuit
Calibration of Data Recorder
Procedure
TABLE 2
7 Calculations When Using Permeameter Procedures
Report When Using Permeameter Procedures
8 Precision and Bias When Using Permeameter Procedures
Calculations When Using Ring Test Procedures
9 Report When Using Ring Test Procedures
Precision and Bias When Using Ring Test Procedures
Keywords
X1. SYMMETRICAL HYSTERESIS LOOPS WITH D-C ELECTRONIC HYSTERESIGRAPHS
X1.1 General
X1.2 Manual Procedure
10 X1.3
REFERENCES