ASTM-C109:2005 Edition
$40.63
C109/C109M-05 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars(Using 2-in. or [50-mm] Cube Specimens)
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 9 |
ASTM C109/C109M-05
Historical Standard: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars(Using 2-in. or [50-mm] Cube Specimens)
ASTM C109/C109M
Scope
1.1 This test method covers determination of the compressive strength of hydraulic cement mortars, using 2-in. or [50-mm] cube specimens.
Note 1—Test Method C 349 provides an alternative procedure for this determination (not to be used for acceptance tests).
1.2 This test method covers the application of the test using either inch-pound or SI units. The values stated in either system shall be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.
1.3 Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and Rounding given in Standard IEEE/ASTM SI 10, of measurements made in other units.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.²)
Keywords
compressive strength; hydraulic cement mortar; hydraulic cement strength; mortar strength; strength
ICS Code
ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
DOI: 10.1520/C0109_C0109M-05
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Summary of Test Method |
2 | Significance and Use Apparatus TABLE 1 |
3 | Materials Temperature and Humidity Test Specimens Preparation of Specimen Molds Procedure |
4 | FIG. 1 |
5 | Calculation TABLE 2 |
6 | Report Faulty Specimens and Retests Precision and Bias Keywords A1. ANALYSES OF TEST RESULTS FOR QUALIFICATION OF ALTERNATE COMPACTION METHODS A1.1 Calculation of Average Within-Batch Standard Devia-tion and Elimination of Outliers A1.2 Summary of Results A1.3 Precision Qualification A1.4 Bias Qualification |
7 | TABLE A1.1 TABLE A1.2 |
8 | TABLE A1.3 TABLE A1.4 |
9 | TABLE A1.5 |