Shopping Cart

No products in the cart.

ASTM-C1189:2002 Edition

$40.63

C1189-02 Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors (Withdrawn 2011)

Published By Publication Date Number of Pages
ASTM 2002 9
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM C1189-02

Historical Standard: Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors (Withdrawn 2011)

ASTM C1189

Scope

1.1 This guide covers calibrating the energy response of the radiation detectors and setting the discriminator and alarm thresholds used in automatic pedestrian special nuclear material (SNM) monitors.

1.2 Automatic pedestrian SNM Monitors and their application are described in Guide C 1112, which suggests that the monitors be calibrated and tested when installed and that, thereafter, the calibration should be checked and the monitor tested with SNM at three-month intervals.

1.3 Dependable operation of SNM monitors rests, in part, on an effective program to test, calibrate, and maintain them. The procedures and methods described in this guide may help both to achieve dependable operation and obtain timely warning of misoperation.

1.4 This guide can be used in conjunction with other ASTM standards. illustrates the relationship between calibration and other procedures described in standard guides, and it also shows how the guides relate to an SNM monitor user. The guides below the user in the figure deal with routine procedures for operational monitors. Note that Guide C 993 is an in-plant performance evaluation that is used to verify acceptable detection of SNM after a monitor is calibrated. The guides shown above the user in give information on applying SNM monitors (C 1112) and on evaluating SNM monitors (C 1169) to provide comparative information on monitor performance.

Keywords

gamma radiation; material control and accountability; neutron radiation; nuclear materials management; radiation detectors; radiation monitors; safeguards; security

ICS Code

ICS Number Code 93.080.30 (Road equipment and installations)

DOI: 10.1520/C1189-02

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
FIG. 1
2 Summary of Guide
Significance and Use
Interferences
Apparatus
Hazards
Pulse-Height Analysis Calibration
3 Procedures
FIG. 2
4 FIG. 3
FIG. 4
5 Setting the Lowest Practical Lower-Level Discriminator Value.
FIG. 5
FIG. 6
FIG. 7
6 FIG. 8
FIG. 9
FIG. 10
7 Transient Signal Detection Methods Calibration
8 Adjusting Background Alarm Thresholds
Application Notes
Keywords
9 REFERENCES
ASTM-C1189