ASTM-C1193:2011 Edition
$58.50
C1193-11a Standard Guide for Use of Joint Sealants
Published By | Publication Date | Number of Pages |
ASTM | 2011 | 35 |
1.1 This guide describes the use of a cold liquid-applied sealant for joint sealing applications. Including joints on buildings and related adjacent areas, such as plazas, decks, and pavements for vehicular or pedestrian use, and types of construction other than highways and airfield pavements and bridges. Information in this guide is primarily applicable to a single and multi-component, cold liquid-applied joint sealant and secondarily to a precured sealant when used with a properly prepared joint opening and substrate surfaces.
1.2 An elastomeric or non-elastomeric sealant described by this guide should meet the requirements of Specification C834 , C920 , or C1311 .
1.3 This guide does not provide information or guidelines for the use of a sealant in a structural sealant glazing application. Guide C1401 should be consulted for this information. Additionally, it also does not provide information or guidelines for the use of a sealant in an insulating glass unit edge seal used in a structural sealant glazing application. Guide C1249 should be consulted for this information.
1.4 Practice C919 should be consulted for information and guidelines for the use of a sealant in an application where an acoustic joint seal is required.
1.5 This guide also does not provide information relative to the numerous types of sealant that are available nor specific generic sealant properties, such as hardness, tack-free time, or curing process, among others.
1.6 The values stated in SI units are to be regarded as the standard. The values given in parenthesis are provided for information only.
1.7 The Committee with jurisdiction for this standard is not aware of any comparable standards published by other organizations.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.
1.9 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Terminology Significance and Use |
3 | General Considerations |
7 | Substrate Cleaner |
8 | Primer |
9 | Sealant Backing |
11 | Joint Filler Bond Breaker FIG. 1 |
12 | Liquid-Applied Sealant FIG. 2 |
17 | Precured Sealant FIG. 3 |
18 | Sealant Joints FIG. 4 |
19 | FIG. 5 FIG. 6 FIG. 7 |
20 | FIG. 8 |
21 | Designing a Sealant Joint for Movement |
22 | Sealant Installation FIG. 9 |
25 | FIG. 10 |
29 | Sealant Joint Maintenance Certification, Marking, Shipping, Preservation, and Safety Keywords |
30 | X1. TEST METHODS TO DETERMINE SEALANT ADHESION CHARACTERISTICS IN SITU X1.1 Method A, Field-Applied Sealant Joint Hand Pull Tab X1.2 Method B, Exposed Surface Finish Hand Pull Tab FIG. X1.1 |
31 | X1.3 Method C, Field-Applied Sealant Joint Hand Pull Flap X1.4 Method D, Water Immersion FIG. X1.2 |
32 | X2. General Index to Topics and Headings as Listed in the Guide X2.1 Index |
34 | REFERENCES |