ASTM-C696 2005
$44.96
C696-99(2005) Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Uranium Dioxide Powders and Pellets
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 16 |
ASTM C696-99-Reapproved2005
Historical Standard: Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Uranium Dioxide Powders and Pellets
ASTM C696
Scope
1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade uranium dioxide powders and pellets to determine compliance with specifications.
1.2 This test method covers the determination of uranium and the oxygen to uranium atomic ratio in nuclear-grade uranium dioxide powder and pellets.
1.4 This test method covers the determination of chlorine and fluorine in nuclear-grade uranium dioxide. With a 1 to 10-g sample, concentrations of 5 to 200 g/g of chlorine and 1 to 200 Ī¼g/g of fluorine are determined without interference.
1.5 This test method covers the determination of moisture in uranium dioxide samples. Detection limits are as low as 10 Ī¼g.
1.6 This test method covers the determination of nitride nitrogen in uranium dioxide in the range from 10 to 250 Ī¼g.
1.7 This test method covers the spectrographic analysis of nuclear-grade UO2 for the 26 elements in the ranges indicated in Table 2.
1.8 For simultaneous determination of trace elements by plasma emission spectroscopy refer to Test Method C 761.
1.9 This test method covers the spectrochemical determination of silver in nuclear-grade uranium dioxide. The relative standard deviation is 15 % for the concentration range of 0.1 to 50 Ī¼g/g.
1.10 This procedure is designed for a rapid determination of surface area of nuclear-grade uranium dioxide (UO2) powders. The determination of surface area by this procedure is automatic, simple, and fast enough to be used in quality control work. The range of analysis is from 1 to 1500 m2/g.
1.11 This test method covers the determination of hydrogen over the range from 0.05 to 100 Ī¼g of hydrogen (H2) in uranium dioxide UO2 pellets by inert gas fusion.
Keywords
impurity content; isotopic composition; stoichiometry; uranium content; uranium dioxide
ICS Code
ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
DOI: 10.1520/C0696-99R05
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Significance and Use Reagents Safety Precautions Sampling Scope Summary of Test Method Interferences Apparatus Procedure |
3 | Calculation Precision and Accuracy Scope Summary of Test Method Apparatus TABLE 1 |
4 | Reagents Procedure FIG. 1 FIG. 2 |
5 | Calculation Precision Scope Summary of Test Method Apparatus Reagents |
6 | Operation Standardization Calculation Precision Scope Summary of Test Method Interferences Apparatus Reagents |
7 | Procedure Calculation Precision Scope Summary of Test Method Significance TABLE 2 |
8 | Apparatus Reagents and Materials Standards Procedures |
9 | FIG. 3 |
10 | Precision and Accuracy Scope Summary of Test Method Scope Summary of Test Method |
11 | Apparatus and Equipment Reagents and Chemicals Procedure |
13 | Calculation Precision and Accuracy Scope Summary of Test Method Apparatus Reagents and Materials Description of Instrument |
14 | Operation of Instrument Calibration with Metal Standards Startup Procedure Procedure Precision and Accuracy Keywords |
15 | REFERENCES |