Scope
1.1 This test method provides a procedure for the sequential leaching of a waste containing at least 5 % dry solids in order to generate solutions to be used to determine the constituents leached under the specified testing conditions.
1.2 This test method calls for the shaking of a known weight of waste with acidic extraction fluid of a specified composition as well as the separation of the liquid phase for analysis. The pH of the extraction fluid is to reflect the pH of acidic precipitation in the geographic region in which the waste being tested is to be disposed. The procedure is conducted ten times in sequence on the same sample of waste, and it generates ten solutions.
1.3 This test method is intended to describe the procedure for performing sequential batch extractions only. It does not describe all types of sampling and analytical requirements that may be associated with its application.
1.4 The values stated in SI units are to be regarded as the standard.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
acidic precipitation; extract; extraction fluid; leaching; sequential batch extraction; waste leaching technique
ICS Code
ICS Number Code 13.030.40 (Installations and equipment for waste disposal and treatment)
DOI: 10.1520/D5284-93R04E01
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Significance and Use |
2 | Apparatus Reagents Sampling |
3 | Sample Preparation FIG. 1 |
4 | Procedure |
5 | Calculation |
6 | Definitions of Variables |
7 | Report FIG. 2 |
8 | FIG. 3 |
9 | Precision and Bias FIG. 3 |
11 | TABLE 1 TABLE 2 |
12 | TABLE 3 TABLE 4 |
13 | FIG. 4 FIG. 5 FIG. 6 FIG. 7 |
14 | Keywords FIG. 8 FIG. 9 FIG. 10 FIG. 11 |
15 | X1. AGITATION TECHNIQUES AND RATE AND LIQUID/SOLID RATIO X1.1 X1.2 X1.3 FIG. 12 |