1.1 This test method covers the determination of pour point of petroleum products by an automatic instrument that tilts the test jar during cooling and detects movement of the surface of the test specimen with an optical device.

1.2 This test method is designed to cover the range of temperatures from -57 to +51°C; however, the range of temperatures included in the 1992 interlaboratory test program only covered the temperature range from -39 to +6°C, and the range of temperatures included in the 1998 interlaboratory test program was -51 to -11°C. (see 13.4).

1.3 Test results from this test method can be determined at 1 or 3°C intervals.

1.4 This test method is not intended for use with crude oils.

Note 1—The applicability of this test method on residual fuel samples has not been verified. For further information on applicability, refer to 13.4.

1.5 The values stated in SI units are regarded as standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

D97 equivalent; petroleum products; pour point; tilt method

ICS Code

ICS Number Code 75.080 (Petroleum products in general)

DOI: 10.1520/D5950-02

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Summary of Test Method
2 Significance and Use
Apparatus
TABLE 1
FIG. 1
3 Reagents and Materials
Sampling
Preparation of Apparatus
Calibration and Standardization
Procedure
FIG. 2
4 Report
Precision and Bias
Keywords