ASTM-D6352 2009
$44.96
D6352-04(2009) Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700°C by Gas Chromatography
Published By | Publication Date | Number of Pages |
ASTM | 2009 | 16 |
ASTM D6352-04-Reapproved2009
Historical Standard: Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700Ā°C by Gas Chromatography
ASTM D6352
Scope
1.1 This test method covers the determination of the boiling range distribution of petroleum distillate fractions. The test method is applicable to petroleum distillate fractions having an initial boiling point greater than 174Ā°C (345Ā°F) and a final boiling point of less than 700Ā°C (1292Ā°F) (C10 to C90) at atmospheric pressure as measured by this test method.
1.2 The test method is not applicable for the analysis of petroleum or petroleum products containing low molecular weight components (for example naphthas, reformates, gasolines, crude oils). Materials containing heterogeneous components (for example alcohols, ethers, acids, or esters) or residue are not to be analyzed by this test method. See Test Methods D 3710, D 2887, or D 5307 for possible applicability to analysis of these types of materials.
1.3 The values stated in SI units are to be regarded as standard. The values stated in inch-pound units are for information only and may be included as parenthetical values.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
boiling range distribution; distillation; gas chromatography; petroleum; petroleum distillate fractions; simulated distillation; Boiling range distribution; Distillation–petroleum products; Gas chromatography (GC)–petroleum products; Petroleum distillates; Petroleum fractions; Simulated distillation
ICS Code
ICS Number Code 75.080 (Petroleum products in general)
DOI: 10.1520/D6352-04R09
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Summary of Test Method Significance and Use Apparatus |
3 | Reagents and Materials Preparation of Apparatus |
4 | TABLE 1 FIG. 1 |
5 | FIG. 2 TABLE 2 TABLE 3 TABLE 4 |
6 | Procedure TABLE 5 |
7 | TABLE 6 FIG. 3 TABLE 7 |
8 | Calculation FIG. 4 |
10 | Report Precision and Bias Keywords X1. BOILING POINT BIASES OF NON-PARAFFINIC HYDROCARBONS X1.1 TABLE 8 |
11 | X1.2 X1.3 TABLE X1.1 FIG. X1.1 TABLE X1.2 |
12 | X1.4 FIG. X1.2 FIG. X1.3 FIG. X1.4 TABLE X1.3 |
13 | X1.5 X1.6 FIG. X1.5 TABLE X1.4 FIG. X1.6 TABLE X1.5 |
14 | X2. CALCULATION ALGORITHM X2.1 Required Starting Elements X2.3 Zero the Data Slices X2.4 Calculate Total Chromatogram Area X2.5 Determine Start of Sample Elution Time |
15 | X2.6 Determine the End of Sample Elution Time X2.7 Calculate Total Corrected Sample Area X2.8 Normalize to Area Percent X2.9 Find Retention Time Corresponding to Percent Off X2.10 Convert Retention Times to Boiling Points X2.11 Reporting Results |