ASTM-D6377 2008
$40.63
D6377-08 Standard Test Method for Determination of Vapor Pressure of Crude Oil: VPCRx (Expansion Method)
Published By | Publication Date | Number of Pages |
ASTM | 2008 | 6 |
ASTM D6377-08
Historical Standard: Standard Test Method for Determination of Vapor Pressure of Crude Oil: VPCRx (Expansion Method)
ASTM D6377
Scope
1.1 This test method covers the use of automated vapor pressure instruments to determine the vapor pressure exerted in vacuum of crude oils. This test method is suitable for testing samples that exert a vapor pressure between 25 and 180 kPa at 37.8Ā°C at vapor-liquid ratios from 4:1 to 0.02:1 (X = 4 to 0.02).
Note 1āThis test method is suitable for the determination of the vapor pressure of crude oils at temperatures from 0 to 100Ā°C and pressures up to 500 kPa, but the precision and bias statements (see Section 14) may not be applicable.
1.2 This test method allows the determination of vapor pressure for crude oil samples having pour points above 0Ā°C.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.2.1-7.3.2.
Keywords
crude oil; expansion method; Reid vapor pressure; vapor pressure; Crude petroleum products; Mini method; Reid vapor pressure; Vapor pressure (VPx)–petroleum products; VPCRx expansion method
ICS Code
ICS Number Code 75.020 (Extraction and processing of petroleum and natural gas)
DOI: 10.1520/D6377-08
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Summary of Test Method Significance and Use Apparatus TABLE 1 |
3 | Reagents and Materials Sampling and Sample Introduction |
4 | Preparation of Apparatus Calibration Quality Control Checks Procedure |
5 | Report Precision and Bias Keywords |
6 | X1.1 X1.2 X2. VAPOR PRESSURE OF CRUDE OIL VERSUS TEMPERATURE X2.1 |