D6581-08 Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography

Published By Publication Date Number of Pages
ASTM 2008 21
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM D6581-08

Historical Standard: Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography

ASTM D6581

Scope

1.1 This multi-test method covers the determination of the oxyhalideschlorite, bromate, and chlorate, and bromide, in raw water, finished drinking water and bottled (non-carbonated) water by chemically and electrolytically suppressed ion chromatography. The ranges tested using this method for each analyte were as follows:

1.1.1 The upper limits may be extended by appropriate sample dilution or by the use of a smaller injection volume. Other ions of interest, such as fluoride, chloride, nitrite, nitrate, phosphate, and sulfate may also be determined using this method. However, analysis of these ions is not the object of this test method.

1.2 It is the user’s responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 This test method is technically equivalent with Part B of U.S. EPA Method 300.1 , titled The Determination of Inorganic Anions in Drinking Water by Ion Chromatography.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

bottled and finished drinking water; bromate; bromide; chemical suppression; chlorate; chlorite; ion chromatography; raw water; sample preservation; Bromate content; Bromide content; Chemically-suppressed ion chromatography (IC); Chlorite content; Drinking water; Ion chromatography (IC)

ICS Code

ICS Number Code 13.060.50 (Examination of water for chemical substances)

DOI: 10.1520/D6581-08

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Significance and Use
Reagents and Materials
Precautions
Sampling and Sample Preservation
Scope
Summary of Test Method A
3 Interferences
Apparatus
FIG. 1
4 Preparation of Apparatus
Reagents and Materials
FIG. 2
TABLE 1
5 Calibration and Standardization
Procedure
Calculation
Precision and Bias
6 Quality Control
TABLE 2
7 TABLE 3
TABLE 4
8 TABLE 5
TABLE 6
TABLE 7
TABLE 8
9 Scope
Summary of Test Method B
Interferences
Apparatus
10 Preparation of Apparatus
FIG. 3
TABLE 9
11 Reagents and Materials
Calibration and Standardization
Procedure
12 Calculations
Precision and Bias
Quality Control
TABLE 10
13 TABLE 11
15 TABLE 12
16 Keywords
TABLE 13
TABLE 14
17 TABLE 15
20 TABLE 16
21 TABLE 17
ASTM-D6581