D6785-08 Standard Test Method for Determination of Lead in Workplace Air Using Flame or Graphite Furnace Atomic Absorption Spectrometry

Published By Publication Date Number of Pages
ASTM 2008 17
Guaranteed Safe Checkout
Categories: , ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This standard specifies flame and graphite furnace atomic absorption spectrometric methods for the determination of the time-weighted average mass concentration of particulate lead and lead compounds in workplace air.

1.2 The method is applicable to personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling.

1.3 The sample dissolution procedure specifies hot plate or microwave digestion, or ultrasonic extraction (11.2). The sample dissolution procedure is not effective for all lead compounds (see Section 5). The use of an alternative, more vigorous dissolution procedure is necessary when it is desired to extract lead from compounds present in the test atmosphere that are insoluble using the dissolution procedures described herein. For example if it is desired to determine silicate lead, a hydrofluoric acid dissolution procedure is required.

1.4 The flame atomic absorption method is applicable to the determination of masses of approximately 1 to 200 ? g of lead per sample, without dilution (1) . The graphite furnace atomic absorption method is applicable to the determination of masses of approximately 0.01 to 0.5 ? g of lead per sample, without dilution (1) .

1.5 The ultrasonic extraction procedure has been validated for the determination of masses of approximately 20 to 100 ? g of lead per sample, for laboratory-generated lead fume air filter samples (2) .

1.6 The concentration range for lead in air for which this procedure is applicable is determined in part by the sampling procedure selected by the user (see Section 10).

1.7 Anions that form precipitates with lead may interfere, but this potential interference is overcome by the addition of the disodium salt of ethylenediamine tetraacetic acid (EDTA) when necessary.

1.8 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
3 Summary of Test Method
Reactions
Significance and Use
Reagents
4 Apparatus
6 Occupational Exposure Assessment
7 Sampling
8 Procedure
12 Calculation
Special Cases
Report
13 Precision and Bias
14 X1. SAMPLER WALL DEPOSITS (
X1.1
X1.2
X1.3
X1.4
X1.5
X1.6
TABLE X1.1
15 X2. GUIDANCE ON FILTER SELECTION
X2.1 Collection Efficiency
X2.2 Dust-loading Capacity
X2.3 Lead Content
X2.4 Weight Stability
X2.5 Solubility
16 X3. TEMPERATURE AND PRESSURE CORRECTION
X3.1 Temperature and Pressure Correction for the Indicated Volumetric Flow Rate
X3.2 Recalculation of Lead in Air Concentrations to Reference Conditions
REFERENCES