ASTM-D6855 2010

$44.96

D6855-10 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode

Published By Publication Date Number of Pages
ASTM 2010 14
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method covers the static determination of turbidity in water (see 4.1).

1.2 This test method is applicable to the measurement of turbidities under 5.0 nephelometric turbidity units (NTU).

1.3 This test method was tested on municipal drinking water, ultra-pure water and low turbidity samples. It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices.

1.4 This test method uses calibration standards are defined in NTU values, but other assigned turbidity units are assumed to be equivalent.

1.5 This test method assigns traceable reporting units to the type of respective technology that was used to perform the measurement. Units are numerically equivalent with respect to the calibration standard. For example, a 1.0 NTU formazin standard is also equal to a 1.0 FNU standard, a 1.0 FNRU standard and so forth.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this procedure.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Test Method
Significance and Use
Interferences
Apparatus
3 TABLE 1
FIG. 1
4 FIG. 2
5 Purity of Reagents
Reagents
FIG. 3
6 Safety
7 Sampling and Sample Preservation
Calibration and Calibration Verification
Procedure for the Measurement of Water Turbidity
8 Report
Quality Control/Quality Assurance
TABLE 2
9 Precision and Bias
Keywords
TABLE 3
10 X1. CLEANING AND MAINTENANCE OF TURBIDITY SAMPLE CELLS AND CAPS
X1.1 Introduction
X1.2 Cleaning
X1.3 Maintenance
X2. PROCEDURE FOR SEASONING GLASSWARE WHEN PREPARING CALIBRATION STANDARDS
X2.1 Introduction
X2.2 Procedure
11 X3. STABILITY OF FORMAZIN
X3.1
X4. CRITICAL VALUES OF F TABLE
X4.1
TABLE X3.1
TABLE X3.2
12 TABLE X4.1
13 X5. SELECTION CRITERIA FLOWCHART FOR TURBIDIMETERS
X5.1
X5.2
REFERENCES
FIG. X5.1
ASTM-D6855 2010
$44.96