Shopping Cart

No products in the cart.

ASTM-D7282 2006

$58.50

D7282-06 Standard Practice for Set-up, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements

Published By Publication Date Number of Pages
ASTM 2006 24
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This practice covers consensus criteria for the calibration and quality control of nuclear instruments. This practice is provided for establishing appropriate quality control parameters at instrument startup, calibration of nuclear counting instruments and the continuing monitoring of quality control parameters. Calibrations are usually performed to establish the operating parameters of the instrument. This practice addresses the typically used nuclear counting instruments: alpha spectrometer, gamma spectrometer, gas proportional counter and liquid scintillation counter.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Summary of Practice
Significance and Use
Hazards
Scope
Significance and Use
Instrument Set-up
4 Scope
Significance and Use
Establishing the Control Chart
5 Instrument Tolerance Limits
Scope
Significance and Use
Gas Proportional Counter Instrument Calibrations
9 Gamma Spectrometry Instrument Calibrations
10 Alpha Spectrometry Instrument Calibrations
12 Liquid Scintillation Counting Instrument Calibrations
13 Scope
Significance and Use
14 Quality Control for Gas Proportional Counters
Quality Control for Gamma Spectrometry Systems
Quality Control for Alpha Spectrometry Systems
15 Quality Control for the Liquid Scintillation Counter
Keywords
16 A1. WORK FLOW CHARTS
FIG. A1.1
17 FIG. A1.2
18 FIG. A1.3
19 X1. GROSS ALPHA CALIBRATION USING Am-241
X1.1
FIG. A1.4
20 X2. GAS PROPORTIONAL COUNTER—ALPHA TO BETA AND BETA TO ALPHA CROSSTALK
X2.1 General Considerations
X2.2
FIG. X1.1
23 X3. MARINELLI BEAKER CALIBRATION USING MIXED STANDARD
X3.1
X4. Ni-63 CALIBRATION
X4.1
FIG. X3.1
24 REFERENCES
FIG. X4.1
ASTM-D7282 2006
$58.50