1.1 This test method covers the laboratory measurement of impact sound transmission of floor-ceiling assemblies using a standardized tapping machine. It is assumed that the test specimen constitutes the primary sound transmission path into a receiving room located directly below and that a good approximation to a diffuse sound field exists in this room.

1.2 Measurements may be conducted on floor-ceiling assemblies of all kinds, including those with floating-floor or suspended ceiling elements, or both, and floor-ceiling assemblies surfaced with any type of floor-surfacing or floor-covering materials.

1.3 This test method prescribes a uniform procedure for reporting laboratory test data, that is, the normalized one-third octave band sound pressure levels transmitted by the floor-ceiling assembly due to the tapping machine.

1.4 Laboratory Accreditation The requirements for accrediting a laboratory for performing this test method are given in Annex A2.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Summary of Test Method
Significance and Use
Test Rooms
3 Test Specimens
Tapping Machine
Instrumentation Requirements
4 Measurement of Sound Pressure Levels
FIG. 1
5 Determination of Receiving Room Sound Absorption
Calculations
Report
TABLE 1
6 Precision and Bias
Keywords
A1. QUALIFICATION OF ROOM SOUND FIELDS AND MICROPHONE SYSTEMS USED FOR SAMPLING
A1.1 Scope
A1.2 Microphone Positions
A1.3 Averaging Time
A1.4 Required Confidence Interval for Sound Pressure Level Measurements
7 A1.5 Measurement Procedures and Calculations
A1.6 Repeatability Tests
TABLE A1.1
8 A2. LABORATORY ACCREDITATION
A2.1 Scope
A2.2 Referenced Documents
A2.3 Laboratory Information
A2.4 Measurement and Calculation Procedures
A2.5 Test Specimens
A2.6 Test Procedures
9 A2.7 Reference Specimen