ASTM-E761/E761M:2015 Edition
$35.75
E761/E761M-92(2015)e1 Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members
Published By | Publication Date | Number of Pages |
ASTM | 2015 | 3 |
ASTM E761/E761M-92-e1-Reapproved2015
Historical Standard: Standard Test Method for Compressive Strength of Sprayed Fire-Resistive Material Applied to Structural Members
ASTM E761/E761M
Scope
1.1 This test method covers a procedure for measuring the compressive strength of sprayed fire-resistive material (SFRM) applied to a rigid substrate. These fire-resistive materials include sprayed fibrous and cementitious materials applied directly in contact with these structural members. The test method is applicable to laboratory procedure.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
compressive strength; sprayed cementitious; sprayed fibrous; sprayed fire resistive materials (SFRMs) ;
ICS Code
ICS Number Code 13.220.50 (Fire-resistance of building materials and elements)
DOI: 10.1520/E0761_E0761M-92R15E01