BS EN 12259-14:2020+A1:2022
$198.66
Fixed firefighting systems. Components for sprinkler and water spray systems – Sprinklers for residential applications
Published By | Publication Date | Number of Pages |
BSI | 2022 | 64 |
This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat and incorporating the following types of water seals: – conical metal spring with a PTFE gasket or coating; – metal cap or disc with PTFE gasket or coating; – copper gasket, with or without a PTFE coating. Sprinklers in accordance with this document will only be used in automatic sprinkler systems for domestic and residential applications as defined in EN 16925.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Construction and performance 4.1 General 4.2 Dimensions and pressure rating 4.2.1 Dimensions 4.2.2 Pressure ratings 4.3 Nominal operating temperature |
11 | 4.4 Operating temperatures 4.5 Water flow and distribution 4.5.1 K-factor 4.5.2 Water distribution 4.5.2.1 Water distribution test – Horizontal surface |
12 | 4.5.2.2 Water distribution test – Vertical surface 4.5.3 Water Impingement Test 4.6 Function 4.7 Fire Test |
13 | 4.8 Strength of sprinkler body and deflector 4.8.1 Strength of frame 4.8.2 Flow endurance 4.8.3 Strength of deflector 4.9 Strength of release element 4.9.1 Glass bulb sprinklers |
14 | 4.9.2 Fusible link sprinklers 4.10 Leak resistance and hydrostatic strength 4.11 Heat exposure 4.11.1 General |
15 | 4.11.2 Additional heat exposure of glass bulb sprinklers 4.11.3 Thermal shock 4.12 Corrosion 4.12.1 Stress corrosion 4.12.2 Sulphur dioxide corrosion 4.12.3 Salt mist corrosion 4.12.4 Moist air 4.13 Water hammer |
16 | 4.14 Thermal response 4.14.1 Oven test 4.14.2 Room response test 4.15 Resistance to vibration 4.16 Resistance to impact 4.17 Resistance to low temperature 4.18 Resistance to heat 4.19 Test conditions 5 Marking 5.1 General 5.2 Identification number |
17 | 5.3 Nominal operating temperature and year of manufacture 5.4 Manufacturing location 5.5 Heat sensitive element supplier 5.6 Protective covers 5.7 Sidewall sprinklers 5.7.1 General 5.7.2 Horizontal sidewall sprinklers 5.8 Concealed sprinklers |
18 | 5.9 Removable recessed housing 6 Instruction charts 6.1 General 6.2 Installation Instructions |
20 | Annex A (normative)Conditions for tests |
21 | Annex B (normative)Water flow test |
23 | Annex C (normative)Water distribution test C.1 Water distribution test – Horizontal surface C.1.1 General C.1.2 Upright, pendant, flush, recessed and concealed sprinklers |
24 | C.1.3 Sidewall Sprinklers |
26 | C.2 Water distribution test – vertical surface C.2.1 Test method |
28 | C.3 Water impingement test |
29 | Annex D (normative)Fire test D.1 Extent of testing |
33 | D.2 Test arrangement D.2.1 Test room |
35 | D.2.2 Fire source |
36 | D.2.3 Sprinkler installation |
37 | D.3 Test method |
38 | D.4 Supplementary test |
39 | Annex E (normative)Function test E.1 Function test E.2 Verification function test |
41 | Annex F (normative)Strength of sprinkler body and deflector F.1 Strength of sprinkler bod |
42 | F.2 Flow endurance test F.3 Deflector strength test |
43 | Annex G (normative)Strength of release elements test G.1 Glass bulbs |
45 | G.2 Fusible links |
46 | Annex H (normative)Leak resistance tests H.1 Leak Test H.2 Hydrostatic Strength Test |
47 | Annex I (normative)Heat exposure I.1 High temperature test I.2 Additional testing of glass bulb sprinklers |
48 | Annex J (normative)Glass bulb sprinkler thermal shock test |
49 | Annex K (normative)Exposure and corrosion tests K.1 Stress corrosion K.1.1 Sample preparation K.1.2 Apparatus K.1.3 Procedure K.2 Sulphur dioxide corrosion K.2.1 Reagents for apparatus of 5 l volume |
50 | K.2.2 Apparatus K.2.3 Procedure |
51 | K.3 Salt mist corrosion K.3.1 Reagents K.3.2 Apparatus K.3.3 Procedure |
52 | K.4 Moist Air K.4.1 Performance criteria K.4.2 Procedure |
53 | Annex L (normative)Water hammer test |
54 | Annex M (normative)Thermal response test M.1 Oven heat test |
55 | M.2 Room heat test M.2.1 Flush, recessed or concealed sprinklers M.2.2 Sprinkler location and orientation M.2.3 Room dimensions and water supply |
56 | M.2.4 Fire source and distance to sprinkler |
59 | Annex N (normative)Vibration test N.1 Sample preparation and performance criteria N.2 Procedure |
60 | Annex O (normative)Impact test |
61 | Annex P (normative)Resistance to low temperature test |
62 | Annex Q (normative)Resistance to high temperature test |