Shopping Cart

No products in the cart.

BS EN 12543-2:2021 – TC

$134.27

Tracked Changes. Non-destructive testing. Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing – Pinhole camera radiographic method

Published By Publication Date Number of Pages
BSI 2021 48
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies a method for the measurement of effective focal spot dimensions above 0,1 mm of X-ray systems up to and including 1000 kV tube voltage by means of the pinhole camera method with digital evaluation. The tube voltage applied for this measurement is restricted to 200 kV for visual film evaluation and may be selected higher than 200 kV if digital detectors are used.

The imaging quality and the resolution of X-ray images depend highly on the characteristics of the effective focal spot, in particular the size and the two dimensional intensity distribution as seen from the detector plane. This method compared to the others in the EN 12543 series allows to obtain an image of the focal spot and to see the state of it (e.g. cratering of the anode).

This test method provides instructions for determining the effective size (dimensions) of standard (macro focal spots) and mini focal spots of industrial X-ray tubes. This determination is based on the measurement of an image of a focal spot that has been radiographically recorded with a “pinhole” technique and evaluated with a digital method.

For the characterization of commercial X-ray tube types (i.e. for advertising or trade) it is advised that the specific FS (Focal spot) values of Annex A are used.

PDF Catalog

PDF Pages PDF Title
28 National foreword
31 European foreword
32 Introduction
33 1 Scope
2 Normative references
3 Terms and definitions
34 4 Test equipment
4.1 Essential characteristics of the pinhole
35 4.2 Alignment and position of the pinhole camera
36 4.3 Position of the radiographic image detector
37 4.4 Requirements on the radiographic image detector
4.5 Image processing equipment for digital images
38 4.6 Loading factors
5 Measurement and determination of the focal spot size
5.1 Measurement procedure
39 5.2 Measurement with digital technique (preferred method)
40 5.3 Evaluation with digital technique using Integrated Line Profiles (ILP)
42 5.4 Measurement of effective focal spot size visually using film radiographs
43 6 Classification and result of focal spot size measurement
45 Annex A (normative) Values for the classification of X-ray tube focal spot sizes
47 Bibliography
BS EN 12543-2:2021 - TC