BS EN 16825:2016+A1:2019
$189.07
Refrigerated storage cabinets and counters for professional use. Classification, requirements and test conditions
Published By | Publication Date | Number of Pages |
BSI | 2019 | 48 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | Contents Page |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Requirements 4.1 Condensate drainage |
13 | 4.2 Operating characteristics 4.2.1 Classification according to temperature 4.2.2 Defrosting 4.2.3 Water vapour condensation 4.2.4 Electrical energy consumption 5 Test conditions 5.1 General |
14 | 5.2 Tests outside test room 5.3 Tests inside test room 5.3.1 General 5.3.2 Test conditions 5.3.2.1 General 5.3.2.2 Test room — General design, walls, floor and radiant heat |
15 | 5.3.2.3 Test room climate definition |
16 | 5.3.2.4 Test packages characteristics |
19 | 5.3.2.5 M-packages |
20 | 5.3.2.6 Test packages life time 5.3.2.7 Instruments, measuring equipment and measuring accuracy |
21 | 5.3.3 Preparation of test cabinet 5.3.3.1 Cabinet selection, installation and positioning within the test room |
22 | 5.3.3.2 Air movement |
23 | 5.3.3.3 Loading the cabinet |
30 | 5.3.3.4 Running in 5.3.3.5 Stable conditions 5.3.3.6 Test conditions |
34 | 5.3.3.7 Lighting 5.3.3.8 Power supply |
35 | 5.3.3.9 Testing several cabinets in the same room 5.3.4 Temperature test 5.3.4.1 Test conditions 5.3.4.2 Temperature curves of M-packages |
37 | 5.3.4.3 Calculation of average mean temperature 5.3.5 Water vapour condensation test 5.3.5.1 Test conditions 5.3.5.2 Test results 5.3.5.3 Observations |
38 | 5.3.5.4 Expression of results and test report 5.3.6 Electrical energy consumption test 5.3.6.1 Test conditions 5.3.6.2 Energy measurement 6 Test procedures 6.1 Calculation of net volume |
39 | 6.2 Load line and cabinet label marking durability 6.3 Tests outside test room – Linear dimensions, areas and volumes |
40 | 6.4 Tests inside test room 6.4.1 Test conditions 6.4.2 Cabinet preparation 6.4.3 Temperature test |
41 | 6.4.4 Water vapour condensation test 6.4.5 Electrical energy consumption test |
42 | 7 Template for information to be declared 8 Load limit marking |
44 | Annex A (informative)Information and accessories to be provided by the manufacturer for the correct performance and reproducibility of tests |
45 | Annex ZA (informative)Relationship between this European Standard and the Ecodesign requirements of Commission Regulation (EU) No 2015/1095 aimed to be covered |
46 | Annex ZB (informative)Relationship between this European Standard and the energy labelling requirements of Commission Delegated Regulation (EU) No 2015/1094 aimed to be covered |