BS EN 16902:2016
$198.66
Commercial beverage coolers. Classification, requirements and test conditions
Published By | Publication Date | Number of Pages |
BSI | 2016 | 66 |
The scope of this European Standard is to define the classification for commercial beverage coolers and to specify their requirements and test methods. This European Standard is applicable to integral refrigeration systems. This European Standard is not applicable to remote and secondary system cabinets.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
9 | 1 Scope 2 Normative references 3 Terms and definitions 3.1 Types of commercial beverage cooler |
10 | 3.2 Parts of commercial beverage cooler |
11 | 3.3 Physical aspects and dimensions |
12 | 3.4 Definitions relating to performance characteristics |
14 | 3.5 Definition related to test environment |
15 | 4 Symbols 5 Classification and requirements 5.1 Classification according to temperature |
16 | 5.2 Construction 5.2.1 General 5.2.1.1 Strength and rigidity 5.2.1.2 Pipes and connections 5.2.1.3 Condensate drainage 5.2.1.4 Joints and seams 5.2.2 Materials 5.2.2.1 General |
17 | 5.2.2.2 Wear resistance 5.2.2.3 Corrosion resistance 5.2.3 Thermal insulation 5.2.3.1 Efficiency 5.2.3.2 Vapour barrier 5.2.3.3 Containment of insulation material 5.2.4 Refrigerating system 5.2.4.1 Design and construction 5.2.4.2 Condensation 5.2.4.3 System protection |
18 | 5.2.4.4 Refrigerant 5.2.5 Electrical components 6 Tests 6.1 General |
19 | 6.2 Tests outside test room 6.2.1 General 6.2.2 Seal test for doors and lids 6.2.3 Test on durability of door and lid 6.2.3.1 Test condition/preparation 6.2.3.2 Opening sequence 6.2.3.3 Closing sequence |
20 | 6.2.4 Linear dimensions, areas and volumes 6.3 Tests inside test room 6.3.1 General |
21 | 6.3.2 Test room condition 6.3.2.1 General design, walls, floor and radiant heat 6.3.2.2 Thermal and air flow characteristics |
22 | 6.3.2.3 Test room climate classes 6.3.2.4 Test room climate measuring point |
25 | 6.3.3 M-can 6.3.3.1 General 6.3.3.2 Instruments, measuring equipment and measuring expanded measurement uncertainty 6.3.4 Preparation of test commercial beverage cooler and general test procedures 6.3.4.1 Commercial beverage cooler selection, installation and positioning within the test room |
26 | 6.3.4.2 Air movement |
28 | 6.3.5 Loading the commercial beverage cooler 6.3.5.1 General 6.3.5.2 M-cans loading |
35 | 6.3.6 Running in period 6.3.7 Stable conditions |
36 | 6.3.8 Lighting and night-covers 6.3.9 Power supply 6.3.10 Testing several commercial beverage coolers in the same room |
37 | 6.3.11 Temperature test 6.3.11.1 General 6.3.11.2 Active mode temperature test |
39 | 6.3.11.3 Half reload test |
41 | 6.3.11.4 EMD test |
43 | 6.3.12 Water vapour condensation test 6.3.12.1 Test conditions 6.3.12.2 Test results |
44 | 6.3.12.3 Expression of results 6.3.13 Electrical energy consumption test 6.3.13.1 Test conditions 6.3.13.2 Energy consumption measurement 6.3.13.3 Calculation of TEC |
45 | 6.3.14 Calculation of specific energy consumption (SEC) 6.4 Test report |
47 | 7 Marking 7.1 Load limit |
49 | 7.2 Marking plate 7.3 Information to be supplied by the manufacturer |
50 | Annex A (informative)Commercial beverage cooler family |
51 | Annex B (normative)Net volume calculation General B.2 Calculation of net volume |
52 | Annex C (normative)Equivalent volume calculation General C.2 Calculation of equivalent volume C.3 Gross volume measurements |
54 | Annex D (normative)TDA calculation D.1 General D.2 Measurement of TDA in a refrigerated display cabinet – Calculation of TDA |
59 | Annex E (informative)Test for absence of odour and taste Preparation and testing E.1.1 Ambient temperature E.1.2 Cleaning E.1.3 Thermostat setting E.1.4 Samples E.1.5 Test period |
60 | E.2 Examination of samples E.2.1 Conditions E.2.2 Evaluation |
61 | Annex F (normative)Performance and energy rating of commercial beverage cooler F.1 Scope F.2 Standard rating conditions for commercial beverage cooler F.3 Specific energy consumption (SEC) for commercial beverage coolers |
62 | Annex ZA (informative)Relationship between this European Standard and the ecodesign requirements of Commission DRAFT Ecodesign Regulation DG ENER LOT12 aimed to be covered |