BS EN 60318-4:2010

$142.49

Electroacoustics. Simulators of human head and ear – Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts

Published By Publication Date Number of Pages
BSI 2010 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60318-4:2010 describes an occluded-ear simulator intended for the measurement of insert earphones in the frequency range from 100 Hz to 10 000 Hz. It is suitable for air conduction hearing aids and earphones, coupled to the ear by means of ear inserts e.g. ear moulds or similar devices. The occluded-ear simulator is also suitable as the basis for an extension intended to simulate the complete ear canal and the outer ear (for instance in head simulators). The occluded-ear simulator simulates the acoustic transfer impedance for the occluded normal adult human ear. However, it does not simulate the leakage between an earmould and a human ear canal; therefore, the results obtained with the occluded-ear simulator may deviate from the performance of an insert earphone on a real ear, especially at low frequencies. Moreover, large performance variations among individual ears will occur which should be considered when using the ear simulator. Above 10 kHz the device does not simulate a human ear, but can be used as an acoustic coupler at additional frequencies up to 16 kHz. Below 100 Hz, the device has not been verified to simulate a human ear, but can be used as an acoustic coupler at additional frequencies down to 20 Hz. IEC 60318-4:2010 cancels and replaces IEC 60711, published in 1981 and constitutes a technical revision. The main changes with respect to the previous edition are listed below: – extension of the usable frequency range to 100 Hz – 16 000 Hz; – addition of values of maximum permitted expanded uncertainties to all tolerances.

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
7 1 Scope
2 Normative references
3 Terms and definitions
9 4 Construction
4.1 General
4.2 Principal cavity dimensions
4.3 Calibrated pressure-type microphone
10 4.4 Pressure equalization
4.5 Acoustic transfer impedance level
4.6 Example of design
Table 1 – Level of the acoustic transfer impedance modulus and associated tolerances
11 5 Calibration
5.1 Atmospheric reference conditions
5.2 Calibration method
6 Coupling of earphones and hearing aids to the occluded-ear simulator
6.1 Audiometers with insert earphones
6.2 In-the-ear hearing aids (custom made)
12 6.3 Hearing aids with insert earphone
Figure 1 – Connection of an in-the-ear hearing aid to the occluded-ear simulator
13 6.4 Behind-the-ear and spectacle hearing aids
Figure 2 – Connection of an insert earphone to the occluded-ear simulator
14 6.5 Modular in-the-ear hearing aids
15 Figure 3 – Connection of a behind-the-ear hearing aid to the occluded-ear simulator
16 7 Maximum permitted expanded uncertainty of measurements
Figure 4 – Connection of an in-the-ear hearing aid (modular type) to the occluded-ear simulator
17 Table 2 – Values of maximum permitted expanded uncertainty Umax for basic type approval measurements
18 Annex A (informative) Example of one specific design of occluded-ear simulator
Figure A.1 – Example of one specific design of occluded-ear simulator
19 Annex B (informative) Principle of calibration for the occluded-ear simulator
20 Table B.1 – Sound pressure level relative to that at the reference frequency 500 Hz (Lp(f)– Lp(500)) for the nominal effective volume (1 260 mm3) of the occluded-ear simulator, and associated tolerances
21 Bibliography