BS EN 60662:2012
$256.21
High-pressure sodium vapour lamps. Performance specifications
Published By | Publication Date | Number of Pages |
BSI | 2012 | 188 |
IEC 60662:2011 specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035. This second edition cancels and replaces the first edition published in 1980 and its amendments. It constitues a technical revision. Main items that required development of the 2nd edition of IEC 60662 are: – restriction to performance requirements. Safety requirements are given in IEC 62035: Discharge lamps (excluding fluorescent lamps) – Safety specifications; – introduction of a test device for ignition; – split of the lamp data sheets which make use of the test device and those which do not; – provisions for measurement during starting, measurement of electrical and photometrical characteristics and tests for lumen maintenance and life; – general review e.g. of maximum lamp outlines and alignment of data; – new order of data sheets by wattage.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
8 | INTRODUCTION |
10 | 4 General lamp requirements |
11 | 5 Marking 6 Dimensions 7 Caps 8 Test requirements for lamp starting, warm-up, electrical and photometric characteristics |
12 | 9 Information for ballast and ignitor design |
14 | 10 Information for luminaire design |
15 | 11 Maximum lamp outlines 12 Numbering system for lamp data sheets |
16 | Annex A(normative) Waveshape of voltage pulses for lamp starting test (schematic drawings) Figures Figure A.1 – Waveshape: positive pulse during positive half cycle Figure A.2 – Waveshape: positive pulse during negative half cycle |
17 | Figure A.3 – Shape and parameters of the pulse used in North America |
18 | Annex B(informative) Diagrammatic data sheets for location of lamp dimensions |
19 | Annex C(normative) Guidance for determining quadrilateral diagrams |
20 | Figure C.1 – Relationship of wattage and voltage of an HPS lamp Figure C.2 – Lamp characteristic curves for several HPS lamps Figure C.3 – Typical ballast characteristic curves Figure C.4 – Typical lag or reactor ballast characteristic curves at different supply voltages |
22 | Figure C.5 – Minimum and maximum wattage lines |
23 | Figure C.6 – Finished quadrilateral relative to the referenceballast curves and drop-out locus |
24 | Annex D(normative) Measurement of voltage increase at lamp terminals for luminaire design |
27 | Annex E(informative) HPS lamp drop-out voltage measurement procedure |
29 | Figure E.1 – Example of test circuit |
30 | Figure E.2 – Typical quadrilateral diagram showing drop-out points |
31 | Figure E.3 – Example plot of 400 W HPS lamp ballast curves showing drop-out points |
32 | Figure E.4 – Incorrect drop-out point measurement due to raising lamp voltage at too high a rate Figure E.5 – Test for lamp-ballast equilibrium |
33 | Annex F(normative) Fixed settings of the ignition device (see 8.2.1) and requirements for ignition Table F.1 – Fixed settings of the ignition device (see 8.2.1) |
34 | Annex G(normative) Method of measuring electrical and photometrical characteristics |
35 | Figure G.1 – Circuit diagram for measurement of lamp characteristics |
36 | Annex H(normative) Method of test for lumen maintenance and life |
37 | Annex I(informative) Maximum lamp outlines Table I.1 – List of data sheets for maximum lamp outlines |
49 | Annex J(normative) Lamp data sheets |
185 | Bibliography |