High-pressure sodium vapour lamps. Performance specifications

Published By Publication Date Number of Pages
BSI 2012 188
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60662:2011 specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035. This second edition cancels and replaces the first edition published in 1980 and its amendments. It constitues a technical revision. Main items that required development of the 2nd edition of IEC 60662 are: – restriction to performance requirements. Safety requirements are given in IEC 62035: Discharge lamps (excluding fluorescent lamps) – Safety specifications; – introduction of a test device for ignition; – split of the lamp data sheets which make use of the test device and those which do not; – provisions for measurement during starting, measurement of electrical and photometrical characteristics and tests for lumen maintenance and life; – general review e.g. of maximum lamp outlines and alignment of data; – new order of data sheets by wattage.

PDF Catalog

PDF Pages PDF Title
6 English

CONTENTS
8 INTRODUCTION
10 4 General lamp requirements
11 5 Marking
6 Dimensions
7 Caps
8 Test requirements for lamp starting, warm-up, electrical and photometric characteristics
12 9 Information for ballast and ignitor design
14 10 Information for luminaire design
15 11 Maximum lamp outlines
12 Numbering system for lamp data sheets
16 Annex A(normative)
Waveshape of voltage pulses for lamp starting test (schematic drawings)
Figures

Figure A.1 – Waveshape: positive pulse during positive half cycle
Figure A.2 – Waveshape: positive pulse during negative half cycle
17 Figure A.3 – Shape and parameters of the pulse used in North America
18 Annex B(informative)
Diagrammatic data sheets for location of lamp dimensions
19 Annex C(normative)
Guidance for determining quadrilateral diagrams
20 Figure C.1 – Relationship of wattage and voltage of an HPS lamp
Figure C.2 – Lamp characteristic curves for several HPS lamps
Figure C.3 – Typical ballast characteristic curves
Figure C.4 – Typical lag or reactor ballast characteristic curves at different supply voltages
22 Figure C.5 – Minimum and maximum wattage lines
23 Figure C.6 – Finished quadrilateral relative to the referenceballast curves and drop-out locus
24 Annex D(normative)
Measurement of voltage increase at lamp terminals for luminaire design
27 Annex E(informative)
HPS lamp drop-out voltage measurement procedure
29 Figure E.1 – Example of test circuit
30 Figure E.2 – Typical quadrilateral diagram showing drop-out points
31 Figure E.3 – Example plot of 400 W HPS lamp ballast curves showing drop-out points
32 Figure E.4 – Incorrect drop-out point measurement due to raising lamp voltage at too high a rate
Figure E.5 – Test for lamp-ballast equilibrium
33 Annex F(normative) Fixed settings of the ignition device (see 8.2.1)
and requirements for ignition
Table F.1 – Fixed settings of the ignition device (see 8.2.1)
34 Annex G(normative)
Method of measuring electrical and photometrical characteristics
35 Figure G.1 – Circuit diagram for measurement of lamp characteristics
36 Annex H(normative)
Method of test for lumen maintenance and life
37 Annex I(informative)
Maximum lamp outlines
Table I.1 – List of data sheets for maximum lamp outlines
49 Annex J(normative)
Lamp data sheets