BS EN IEC 62040-1:2019+A11:2021
$215.11
Uninterruptible power systems (UPS) – Safety requirements
Published By | Publication Date | Number of Pages |
BSI | 2021 | 82 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Blank Page |
7 | Blank Page |
8 | Blank Page |
9 | Annex ZZ (informative)Relationship between this European Standard and the safety objectives of Directive 2014/35/EU [2014 OJ L96] aimed to be covered |
11 | English CONTENTS |
13 | FOREWORD |
15 | INTRODUCTION |
16 | 1 Scope 2 Normative references |
17 | 3 Terms and definitions |
18 | Tables Table 1 – Alphabetical list of terms |
24 | 4 Protection against hazards |
25 | Table 101 – UPS input port configuration |
27 | Figures Figure 101 – Examples of design of openings preventing vertical access |
28 | Table 102 – Overvoltage categories |
30 | Table 103 – Maximum temperature limits for magnetic components during stored energy mode of operation |
37 | 5 Test requirements |
38 | Table 22 – Test overview |
43 | Figure 102 – Test circuit for load-induced change of reference potential – Single-phase output Figure 103 – Test circuit for load-induced change of reference potential – Three-phase output |
46 | Table 104 – Short-time withstand current |
49 | Table 105 – Temperature limits for transformer windings |
51 | 6 Information and marking requirements |
54 | Figure 104 – Voltage backfeed warning label |
58 | Annexes |
59 | Annex A (normative) Additional information for protection against electric shock Table A.101 – Comparison of limits of working voltage |
60 | Annex M (informative) Test probes for determining access |
61 | Annex AA (informative) Minimum and maximum cross-section of copper conductors suitable for connection to terminals for external conductor Figure M.101 – Jointed test finger (IP2X) |
62 | Table AA.1 – Conductor cross-sections(extract from IEC 61439-1:2011) |
63 | Annex BB (normative) Reference loads Figure BB.1 – Reference resistive load |
64 | Figure BB.2 – Reference inductive-resistive load (series) Figure BB.3 – Reference inductive-resistive load (parallel) Figure BB.4 – Reference capacitive-resistive load (series) Figure BB.5 – Reference capacitive-resistive load (parallel) |
65 | Figure BB.6 – Reference non-linear load |
67 | Annex CC (normative) Ventilation of lead-acid battery compartments |
70 | Annex DD (informative) Guidance for disconnection of batteries during shipment Figure DD.1 – Precautionary label for products shipped with the battery disconnected |
71 | Figure DD.2 – Precautionary label for products shipped with the battery connected |
72 | Annex EE (informative) Short-time withstand current test procedure – Guidance and typical values Figure EE.1 – 3-wire test circuit for UPS short-time withstand current |
73 | Figure EE.2 – 4-wire test circuit for UPS short-time withstand current |
74 | Figure EE.3 – 2-wire test circuit for single phase UPS short-time withstand current |
76 | Annex FF (informative) Maximum heating effect in transformer tests Table FF.1 – Test steps |
78 | Annex GG (normative) Requirements for the mounting means of rack-mounted equipment |
80 | Bibliography |