Shopping Cart

No products in the cart.

BS ISO 18560-1:2014

$142.49

Fine ceramics (advanced ceramics, advanced technical ceramics). Test method for air-purification performance of semiconducting photocatalytic materials by test chamber method under indoor lighting environment – Removal of formaldehyde

Published By Publication Date Number of Pages
BSI 2014 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of ISO 18560 specifies a test method for the determination of the air-purification performance of materials that contain a indoor-light-active photocatalyst or have indoor-light-active photocatalytic films on the surface, usually made from semiconducting metal oxides, such as titanium dioxide or other ceramic materials, by continuous exposure of a test piece to the model air pollutant under illumination with indoor light. Formaldehyde (HCHO) is chosen because it is a typical indoor air pollutant that causes the so-called sick building syndrome. This part of ISO 18560 is intended to evaluate the photocatalytic performance for building materials, such as boards, wallpapers. This part of ISO 18560 does not apply to powder or granular photocatalytic materials.

This test method is usually applicable to indoor-light-active photocatalytic materials produced for air purification. This method is not suitable for the determination of other performance attribute of photocatalytic materials, i.e. decomposition of water contaminants, self-cleaning, antifogging and antibacterial actions. This test method is based on ISO 16000-23 and is adjusted for the measurement of indoor-light-active photocatalytic materials.

NOTE Another test method for the determination of air-purification performance of photocatalytic materials by using formaldehyde is described in ISO 22197-4. The test methods comprising of ISO 22197 are prepared for evaluation of material-based air-purification performance under irradiation of ultraviolet light, while this part of ISO 18560 is intended for providing a direct index to the improvement of indoor air quality by the indoor-light-active photocatalytic materials under the simulated conditions. Approximate correlation between the results by ISO 22197-4 and this part of ISO 18560 has been confirmed.

PDF Catalog

PDF Pages PDF Title
6 Foreword
7 1 Scope
2 Normative references
8 3 Terms and definitions
9 4 Symbols
10 5 Principle
6 Apparatus
6.1 General
11 6.2 Test chamber
6.3 Sealing material for test specimens
6.4 Air purifier
12 6.5 Supply air spiked with formaldehyde
6.6 Temperature and humidity controls
6.7 Air flow meter
6.8 Light source and UV sharp cut-off filter
6.9 Air sampling devices
6.10 Device to circulate air and control of air velocity
13 6.11 Analytical instrument
7 Test conditions
7.1 General
7.2 Test conditions of removal performance
14 7.3 Factors affecting the removal performance (optional)
15 8 Verification of test conditions
8.1 Monitoring of test conditions
8.2 Air-tightness of test chamber
8.3 Air change rate in test chamber
8.4 Efficiency of the internal test chamber air mixing
8.5 Recovery
9 Preparation of test chamber
16 10 Test specimen
10.1 Preparation of test specimen
10.2 Preparation for the test
11 Test methods
11.1 Background concentration and supply air spiked with formaldehyde
11.2 Placing the test specimen in the test chamber
11.3 Test under dark condition
17 11.4 Test for removal performance
11.5 Factors affecting the removal performance
11.6 Air sampling
12 Determination of formaldehyde
13 Calculation and expression of results
18 14 Test report
20 Annex A
(informative)

Example of a test chamber

23 Bibliography
BS ISO 18560-1:2014
$142.49