BSI 23/30468955 DC 2023
$13.70
BS EN IEC 60404-18. Magnetic materials – Part 18. Permanent magnet (magnetically hard) materials. Methods of measurement of the magnetic properties in an open magnetic circuit using a superconducting magnet
Published By | Publication Date | Number of Pages |
BSI | 2023 | 31 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30468955-NC.pdf |
3 | 68_735e_CD.pdf |
6 | FOREWORD |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 General principle 4.1 Principle of the method |
12 | 4.2 Superconducting magnet (SCM) 4.3 Magnetic field strength sensor (H sensor) 4.4 Magnetic dipole moment detection coil (M coil) |
13 | 4.5 Specimen rod and moving device 4.6 Measuring devices and the data processing device |
14 | 5 Test specimen 6 Preparation of measurement 6.1 Measurement of volume of the test specimen 6.2 Initial magnetization of the test specimen to saturation |
15 | 7 Determination of magnetic polarization 7.1 Measurement of the magnetic dipole moment 7.2 Determination of magnetic polarization |
16 | 8 Measurement of magnetic field 9 Calibration of the magnetic dipole moment detection coil (M coil) 10 Determination of demagnetization curve |
17 | 11 Demagnetizing field correction 11.1 General 11.2 Method A: Method using a demagnetizing factor determined by the shape of the test specimen only |
18 | 11.3 Method B: Method using a demagnetizing factor determined by the shape and the magnetic susceptibility of the test specimen 11.4 Method C: Method using an inverse analysis considering the spatial distribution of the self-demagnetizing field strength in the test specimen |
19 | 12 Determination of principal magnetic properties 12.1 Remanent magnetic polarization Jr 12.2 Maximum energy product (BH)max 12.3 Coercivity (HcJ and HcB) 13 Reproducibility of the measurements 14 Test report |
21 | Annex A (informative) Demagnetizing field correction |
23 | Annex B (informative) Details of the demagnetizing field correction B.1 General B.2 Symbols |
24 | B.3 Method using a demagnetizing factor determined by the shape and magnetic susceptibility of the test specimen (Method B) |
26 | B.4 Method using an inverse analysis considering the spatial distribution of the self-demagnetizing field strength in the test specimen (Method C) |
29 | Annex C (informative) VSM measurement of the test specimen at elevated temperatures |
30 | Annex D (informative) Effect of test specimen dimensions on the magnetic properties |
31 | Bibliography |