This document provides a fire engineering application relative to fire resistance assessment of an airport terminal structure according to the methodology given in ISO 24679‑1 . It follows step by step the procedure given by ISO 24679‑1 . Some requirements relative to Chinese building regulation are taken into account concerning the fire scenarios.
The fire safety engineering applied to an airport terminal takes into account the real fire data based in fire tests. It is important to note that the intervention of fire service brigade dedicated to this airport, located approximately 1 km away, has been taken into account in definition of fire scenarios. For the fire modelling, both fire extinguishing system and the smoke extraction are not considered but the fire fighter intervention has been taken into account 10 min after the starting of fire.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms, definitions and symbols |
11 | 4 Design strategy for fire safety of structures 5 Quantification of the performance of structures in fire 5.1 Step 1: Scope of the project for fire safety of structures 5.1.1 Built environment characteristics |
12 | 5.1.2 Fuel loads |
13 | 5.1.3 Mechanical actions |
14 | 5.2 Step 2: Identify objectives, functional requirements and performance criteria for fire safety of structures |
15 | 5.3 Step 3: Trial design plan for fire safety of structures |
17 | 5.4 Step 4: Design fire scenarios and design fires |
18 | 5.4.1 Design fire scenarios |
19 | 5.4.2 Design fires (thermal actions) |
25 | 5.5 Step 5: Thermal response of the structure 5.5.1 Smoke temperature from FDS simulation |
27 | 5.5.2 Calculating steel temperature exposed to smoke |
28 | 5.6 Step 6: Mechanical response of the structure |
29 | 5.6.1 Deformation analysis of the structure |
30 | 5.6.2 Strength analysis of the main span under fire exposure |
34 | 5.7 Step 7: Assessment against the fire safety objectives |
35 | 5.8 Step 8: Documentation of the design for fire safety of structures |
36 | 5.9 Factors and influences to be considered in the quantification process 5.9.1 Material properties |
38 | 5.9.2 Effect of continuity and restraint (interaction between elements and materials) 5.9.3 Use of test results 5.9.4 Fire spread routes |
39 | 6 Guidance on use of engineering methods |
40 | Annex A (informative) Views and plans of the airport terminal |
42 | Bibliography |