Shopping Cart

No products in the cart.

IEEE 8802-3:2021/Amd 4-2021

$59.04

IEEE/ISO/IEC Telecommunications and exchange between information technology systems — Requirements for local and metropolitan area networks — Part 3: Standard for Ethernet
AMENDMENT 4: Physical layers and management parameters for 50 Gb/s,200 Gb/s, and 400 Gb/s operation over single-mode fiber

Published By Publication Date Number of Pages
IEEE 2021 90
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Adoption Standard – Active. This amendment to IEEE Std 802.3-2018 adds Physical Layer (PHY) specifications and management parameters for 50 Gb/s, 200 Gb/s, and 400 Gb/s operation over single-mode fiber with reaches of at least 40 km.

PDF Catalog

PDF Pages PDF Title
4 Blank Page
5 Title page
7 Important Notices and Disclaimers Concerning IEEE Standards Documents
10 Participants
13 Introduction
16 Contents
22 1. Introduction
1.4 Definitions
23 30. Management
30.5 Layer management for medium attachment units (MAUs)
30.5.1 MAU managed object class
30.5.1.1 MAU attributes
30.5.1.1.2 aMAUType
24 45. Management Data Input/Output (MDIO) Interface
45.2 MDIO Interface Registers
45.2.1 PMA/PMD registers
45.2.1.6 PMA/PMD control 2 register (Register 1.7)
25 45.2.1.7 PMA/PMD status 2 register (Register 1.8)
45.2.1.7.4 Transmit fault (1.8.11)
45.2.1.7.5 Receive fault (1.8.10)
26 45.2.1.8 PMD transmit disable register (Register 1.9)
45.2.1.17a 50G PMA/PMD extended ability register (Register 1.20)
45.2.1.17a.1a 50GBASE-ER ability (1.20.5)
27 45.2.1.20 200G PMA/PMD extended ability register (Register 1.23)
45.2.1.20.1a 200GBASE-ER4 ability (1.23.6)
45.2.1.20.5 200GBASE-SR4 ability (1.23.2)
45.2.1.20.6 200GBASE-CR4 ability (1.23.1)
45.2.1.20.7 200GBASE-KR4 ability (1.23.0)
28 45.2.1.21 400G PMA/PMD extended ability register (Register 1.24)
45.2.1.21.1a 400GBASE-ER8 ability (1.24.10)
45.2.1.21b 40G/100G PMA/PMD extended ability 2 (Register 1.26)
29 45.2.1.21b.1 100GBASE-SR2 ability (1.26.9)
45.2.1.21b.2 100GBASE-CR2 ability (1.26.8)
45.2.1.21b.3 100GBASE-KR2 ability (1.26.7)
45.2.1.21b.4 100GBASE-DR ability (1.26.3)
30 78. Energy-Efficient Ethernet (EEE)
78.1 Overview
78.1.4 PHY types optionally supporting EEE
31 116. Introduction to 200 Gb/s and 400 Gb/s networks
116.1 Overview
116.1.2 Relationship of 200 Gigabit and 400 Gigabit Ethernet to the ISO OSI reference model
116.1.3 Nomenclature
32 116.1.4 Physical Layer signaling systems
33 116.4 Delay constraints
34 121. Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-DR4
121.7 PMD to MDI optical specifications for 200GBASE-DR4
121.7.1 200GBASE-DR4 transmitter optical specifications
35 121.7.2 200GBASE-DR4 receive optical specifications
36 121.7.3 200GBASE-DR4 illustrative link power budget
121.8 Definition of optical parameters and measurement methods
121.8.1 Test patterns for optical parameters
37 121.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
121.8.5.1 TDECQ conformance test setup
121.8.5.3 TDECQ measurement method
121.8.5.4 TDECQ reference equalizer
121.8.6a Transmitter transition time
38 121.8.8 Receiver sensitivity
121.8.9 Stressed receiver sensitivity
121.8.9.1 Stressed receiver conformance test block diagram
39 121.8.9.2 Stressed receiver conformance test signal characteristics and calibration
121.12 Protocol implementation conformance statement (PICS) proforma for Clause 121, Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-DR4
121.12.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-DR4
121.12.4.4 Optical measurement methods
40 122. Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8
122.1 Overview
42 122.2 Physical Medium Dependent (PMD) service interface
122.3 Delay and Skew
122.3.1 Delay constraints
122.5 PMD functional specifications
43 122.5.1 PMD block diagram
122.5.4 PMD global signal detect function
44 122.5.7 PMD global transmit disable function (optional)
122.5.8 PMD lane-by-lane transmit disable function
122.6 Wavelength-division-multiplexed lane assignments
45 122.7 PMD to MDI optical specifications for 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8
46 122.7.1 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE- LR8, and 400GBASE-ER8 transmitter optical specifications
49 122.7.2 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE- LR8, and 400GBASE-ER8 receive optical specifications
51 122.7.3 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE- LR8, and 400GBASE-ER8 illustrative link power budgets
52 122.8 Definition of optical parameters and measurement methods
122.8.1 Test patterns for optical parameters
122.8.2 Wavelength and side mode suppression ratio (SMSR)
122.8.3 Average optical power
53 122.8.4 Outer Optical Modulation Amplitude (OMAouter)
122.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
122.8.5.1 TDECQ conformance test setup
54 122.8.5.2 Channel requirements
122.8.5.3 TDECQ measurement method
122.8.5.4 TDECQ reference equalizer
55 122.8.6 Extinction ratio
122.8.6a Transmitter transition time
122.8.7 Relative intensity noise (RIN17.1OMA, and RIN15.6OMA, and RIN15OMA)
122.8.8 Receiver sensitivity
57 122.8.9 Stressed receiver sensitivity
58 122.8.9.1 Stressed receiver conformance test block diagram
122.8.9.2 Stressed receiver conformance test signal characteristics and calibration
122.9 Safety, installation, environment, and labeling
122.9.2 Laser safety
59 122.9.4 Environment
122.9.5 Electromagnetic emission
122.9.7 PMD labeling requirements
122.10 Fiber optic cabling model
60 122.11 Characteristics of the fiber optic cabling (channel)
122.11.1 Optical fiber cable
122.11.2 Optical fiber connection
122.11.2.1 Connection insertion loss
61 122.11.2.2 Maximum discrete reflectance
122.11.3 Medium Dependent Interface (MDI) requirements
122.11a Requirements for interoperation between 200GBASE-ER4 and 200GBASE-LR4
62 122.11b Requirements for interoperation between 400GBASE-ER8 and 400GBASE-FR8
122.11c Requirements for interoperation between 400GBASE-ER8 and 400GBASE-LR8
63 122.12 Protocol implementation conformance statement (PICS) proforma for Clause 122, Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8
122.12.1 Introduction
122.12.2 Identification
122.12.2.2 Protocol summary
64 122.12.3 Major capabilities/options
122.12.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 200GBASE-FR4, 200GBASE-LR4, 200GBASE-ER4, 400GBASE-FR8, and 400GBASE-LR8, and 400GBASE-ER8
65 122.12.4.4a PMD to MDI optical specifications for 200GBASE-ER4
122.12.4.6a PMD to MDI optical specifications for 400GBASE-ER8
122.12.4.7 Optical measurement methods
122.12.4.8 Environmental specifications
66 124. Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-DR4
124.7 PMD to MDI optical specifications for 400GBASE-DR4
124.7.1 400GBASE-DR4 transmitter optical specifications
67 124.7.2 400GBASE-DR4 receive optical specifications
124.8 Definition of optical parameters and measurement methods
124.8.1 Test patterns for optical parameters
68 124.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
124.8.6a Transmitter transition time
69 124.8.9 Stressed receiver sensitivity
124.12 Protocol implementation conformance statement (PICS) proforma for Clause 124, Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-DR4
124.12.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 400GBASE-DR4
124.12.4.4 Optical measurement methods
70 131. Introduction to 50 Gb/s networks
131.1 Overview
131.1.2 Relationship of 50 Gigabit Ethernet to the ISO OSI reference model
131.1.3 Nomenclature
131.1.4 Physical Layer signaling systems
71 131.4 Delay constraints
72 138. Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-SR, 100GBASE-SR2, 200GBASE-SR4
138.8 Definition of optical parameters and measurement methods
138.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
138.8.10 Stressed receiver sensitivity
73 139. Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER
139.1 Overview
74 139.2 Physical Medium Dependent (PMD) service interface
75 139.3 Delay and Skew
139.3.1 Delay constraints
139.5 PMD functional specifications
139.5.1 PMD block diagram
139.6 PMD to MDI optical specifications for 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER
76 139.6.1 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER transmitter optical specifications
77 139.6.2 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER receive optical specifications
78 139.6.3 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER illustrative link power budgets
79 139.7 Definition of optical parameters and measurement methods
139.7.1 Test patterns for optical parameters
139.7.2 Wavelength and side-mode suppression ratio (SMSR)
139.7.3 Average optical power
80 139.7.4 Outer Optical Modulation Amplitude (OMAouter)
139.7.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
139.7.5.2 Channel requirements
139.7.5.3 TDECQ measurement method
81 139.7.5.4 TDECQ reference equalizer
139.7.6 Extinction ratio
139.7.8 Relative intensity noise (RIN17.1OMA, and RIN15.6OMA, and RIN15OMA)
139.7.9 Receiver sensitivity
82 139.7.10 Stressed receiver sensitivity
139.7.10.2 Stressed receiver conformance test signal characteristics and calibration
83 139.8 Safety, installation, environment, and labeling
139.8.2 Laser safety
139.8.4 Environment
139.8.5 Electromagnetic emission
84 139.9 Fiber optic cabling model
139.10 Characteristics of the fiber optic cabling (channel)
139.10.1 Optical fiber cable
85 139.10.2 Optical fiber connection
139.10.2.1 Connection insertion loss
139.10.2.2 Maximum discrete reflectance
139.10.3 Medium Dependent Interface (MDI) requirements
86 139.10a Requirements for interoperation between 50GBASE-ER and 50GBASE-FR
139.10b Requirements for interoperation between 50GBASE-ER and 50GBASE-LR
139.11 Protocol implementation conformance statement (PICS) proforma for Clause 139, Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER
87 139.11.1 Introduction
139.11.2 Identification
139.11.2.2 Protocol summary
139.11.3 Major capabilities/options
88 139.11.4 PICS proforma tables for Physical Medium Dependent (PMD) sublayer and medium, type 50GBASE-FR, and 50GBASE-LR, and 50GBASE-ER
139.11.4.4a PMD to MDI optical specifications for 50GBASE-ER
89 140. Physical Medium Dependent (PMD) sublayer and medium, type 100GBASE-DR
140.7 Definition of optical parameters and measurement methods
140.7.5 Transmitter and dispersion eye closure for PAM4 (TDECQ)
140.7.10 Stressed receiver sensitivity
IEEE 8802-3:2021/Amd 4-2021
$59.04