IEEE C57.152 2013

$81.25

IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors

Published By Publication Date Number of Pages
IEEE 2013 121
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. Diagnostic tests and measurements that are performed in the field on fluid-filled power transformers and regulators are described. Whenever possible, shunt reactors are treated in a similar manner to transformers. Tests are presented systematically in categories depending on the subsystem of the unit being examined. A diagnostic chart is included as an aid to identify the various subsystems. Additional information is provided regarding specialized test and measuring techniques. Interpretive discussions are also included in several areas to provide additional insight on the particular test or to provide guidance on acceptance criteria. These discussions are based on the authors judgment of accepted practice. It should be noted that the results of several types of tests should be interpreted together to diagnose a problem. Manufacturers acceptance criteria should also be consulted as it may take precedence over the criteria in this guide.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C57.152-2013 Front cover
3 Title page
6 Notice to users
Laws and regulations
Copyrights
Updating of IEEE documents
Errata
Patents
8 Participants
11 Introduction
12 Contents
13 Important notice

1. Scope
14 2. Normative references
3. Definitions
15 4. Purpose of tests
17 5. Maintenance tests and information
5.1 Recommended, as-needed, and optional maintenance tests
18 5.2 EPRI Power Transformer Maintenance and Application Guide
19 6. Safety
6.1 General
6.2 Types of hazards
20 6.3 Creating an electrically safe work condition
22 6.4 General practices for internal inspection
6.5 Suggested general control measures
24 6.6 Apparatus
7. Tests and test techniques
7.1 Periodic general inspections
26 7.2 Main tank (active part)
71 7.3 Bushings
73 7.4 Tap changers
79 7.5 Ancillary equipment
85 8. Diagnostic chart
88 Annex A (informative) Power factor measurements
A.1 General
90 A.2 Test equipment
A.3 Test modes
93 A.4 Simple and complex insulating systems
94 Annex B (informative) Bushings
97 Annex C (informative) Infrared temperature measurements
C.1 General
C.2 IR temperature measurement
100 Annex D (informative) Dew point test
D.1 General
D.2 Dew point test
103 Annex E (informative) Furan testing
105 Annex F (informative) Frequency response testing
F.1 General
F.2 Purpose
106 F.3 Test equipment
F.4 Test procedure
107 F.5 Analysis of results
109 Annex G (informative) Dielectric frequency response
G.1 General
G.2 DFR test procedure
110 G.3 DFR test analysis
113 Annex H (informative) Other methods to verify polarity from previous field test guide revisions
H.1 Verification of transformer polarity
114 H.2 Voltmeter method for ratio
H.3 Ratio measurement using a capacitance and power factor bridge
115 Annex I (informative) Particle count
I.1 Sampling
I.2 Particle count interpretation
118 Annex J (informative) Bibliography