NY – PDF Standards Store ?u= Sat, 26 Oct 2024 18:38:25 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png NY – PDF Standards Store ?u= 32 32 NewYork StateClimateSummary 2022 ?u=/product/publishers/ny/newyork-stateclimatesummary-2022/ Sun, 20 Oct 2024 10:05:19 +0000 New York State Climate Summary
Published By Publication Date Number of Pages
NY 2022 5
]]>
None

]]>
NY NYC FireCode 2022 1stptg ?u=/product/publishers/ny/ny-nyc-firecode-2022-1stptg/ Sun, 20 Oct 2024 06:23:16 +0000 New York City Fire Code
Published By Publication Date Number of Pages
NY 2022
]]>
This is a fully integrated custom code based on the 2015 International Fire Code. Effective date: April 15, 2022

PDF Catalog

PDF Pages PDF Title
1 2022 NEW YORK CITY FIRE CODE®
2 2022 NEW YORK CITY FIRE CODE®
5 COPYRIGHT
7 PREFACE
8 TABLE OF CONTENTS
16 CHAPTER 1 ADMINISTRATION
SECTION FC 101 GENERAL
SECTION FC 102 APPLICABILITY
17 SECTION FC 103 RESERVED
SECTION FC 104 DUTIES AND POWERS OF COMMISSIONER
20 SECTION FC 105 PERMITS AND OTHER APPROVALS
26 FC TABLE 105.6(1) PERMIT QUANTITIES FOR COMPRESSED GASES
FC TABLE 105.6(2) PERMIT QUANTITIES FOR CRYOGENIC FLUIDS
28 FC TABLE 105.6(3) PERMIT QUANTITIES FOR HAZARDOUS MATERIALS
29 FC TABLE 105.6(3)—continued PERMIT QUANTITIES FOR HAZARDOUS MATERIALS
FC TABLE 105.6(4) PERMIT QUANTITIES FOR FLAMMABLE SOLIDS
31 SECTION FC 106 INSPECTIONS
SECTION FC 107 MAINTENANCE
32 SECTION FC 108 RESERVED
SECTION FC 109 VIOLATIONS
SECTION FC 110 RESERVED
SECTION FC 111 ORDER TO DISCONTINUE WORK
33 SECTION FC 112 CERTIFICATE OF APPROVAL
34 SECTION FC 113 CERTIFICATES OF FITNESS AND QUALIFICATION
35 SECTION FC 114 CERTIFICATES OF LICENSE
36 SECTION FC 115 COMPANY CERTIFICATES
37 SECTION FC 116 EXPEDITOR REGISTRATION CERTIFICATES
SECTION FC 117 FEES
40 CHAPTER 2 DEFINITIONS
SECTION FC 201 GENERAL
SECTION FC 202 DEFINITIONS
66 CHAPTER 3 GENERAL PRECAUTIONS AGAINST FIRE
SECTION FC 301 GENERAL
SECTION FC 302 DEFINITIONS
SECTION FC 303 TAR KETTLES AND ASPHALT MELTERS
67 SECTION FC 304 STORAGE AND ACCUMULATION OF RUBBISH AND OTHER COMBUSTIBLE WASTE
SECTION FC 305 IGNITION SOURCES
SECTION FC 306 MOTION PICTURE FILM AND SCREENS
68 SECTION FC 307 OPEN FIRES
69 SECTION FC 308 OPEN FLAMES
72 SECTION FC 309 POWERED INDUSTRIAL TRUCKS, EQUIPMENT AND MOBILITY DEVICES
74 SECTION FC 310 SMOKING
75 SECTION FC 311 VACANT AND TEMPORARILY UNOCCUPIED PREMISES
SECTION FC 312 VEHICLE IMPACT PROTECTION
76 SECTION FC 313 PORTABLE FUELED EQUIPMENT
77 SECTION FC 314 INDOOR DISPLAYS
78 SECTION FC 315 COMBUSTIBLE MATERIALS STORAGE AND OTHER STORAGE HAZARDS
80 SECTION FC 316 HAZARDS TO EMERGENCY RESPONDERS
SECTION FC 317 AUTOMOTIVE SALVAGE AND WRECKING FACILITIES
81 SECTION FC 318 ROOFTOP GARDENS AND LANDSCAPING
82 SECTION FC 319 RESERVED
SECTION FC 320 LAUNDRY CARTS
SECTION FC 321 FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS
SECTION FC 322 ROAD TUNNELS, BRIDGES AND OTHER LIMITED ACCESS HIGHWAYS
83 SECTION FC 323 WASTEWATER TREATMENT AND COLLECTION FACILITIES
SECTION FC 324 ELECTRIC GENERATING PLANTS
SECTION FC 325 PRODUCTION LOCATIONS
86 CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION FC 401 GENERAL
89 FC TABLE 401.4.5.2.3 FLS STAFF TRAINING
92 FC TABLE 401.7.6 DRILL PARTICIPATION AND FREQUENCY
93 SECTION FC 402 DEFINITIONS
SECTION FC 403 PUBLIC GATHERINGS
94 SECTION FC 404 OFFICE BUILDINGS
SECTION FC 405 HOTELS, MOTELS AND OTHER TRANSIENT RESIDENTIAL OCCUPANCIES
96 SECTION FC 406 APARTMENT BUILDINGS
SECTION FC 407 ASSEMBLY OCCUPANCIES
98 SECTION FC 408 ASSISTED LIVING FACILITIES AND SIMILAR OCCUPANCIES
SECTION FC 409 CORRECTIONAL FACILITIES AND OTHER SECURED FACILITIES
SECTION FC 410 EDUCATIONAL OCCUPANCIES
99 SECTION FC 411 FACTORIES
SECTION FC 412 HIGH HAZARD OCCUPANCIES
100 SECTION FC 413 HOSPITALS, NURSING HOMES AND OTHER PATIENT AND RESIDENTIAL CAREFACILITIES
101 SECTION FC 414 MERCANTILE OCCUPANCIES AND COVERED MALLS
SECTION FC 415 WAREHOUSES AND OTHER STORAGE OCCUPANCIES
SECTION FC 416 MIXED OCCUPANCY BUILDINGS
104 CHAPTER 5 FIRE OPERATIONS FEATURES
SECTION FC 501 GENERAL
105 SECTION FC 502 DEFINITIONS
SECTION FC 503 FIRE APPARATUS ACCESS
107 FC FIGURE 503.2.7.2.1 NO PARKING SIGN FIRE APPARATUS ACCESS ROAD
FC TABLE 503.2.9.1 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
108 FC FIGURE 503.2.9 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND
109 FC FIGURE 503.4.1 FIRE LANE SIGN
SECTION FC 504 BUILDING AND ROOFTOP ACCESS
113 SECTION FC 505 PREMISES IDENTIFICATION
114 SECTION FC 506 KEYS AND KEY ACCESS
115 SECTION FC 507 FIRE PROTECTION WATER SUPPLIES
SECTION FC 508 RESERVED
116 SECTION FC 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
SECTION FC 510 IN-BUILDING AUXILIARY RADIO COMMUNICATION SYSTEMS
SECTION FC 511 HIGH-RISE MEGASTRUCTURE FIRE OPERATIONS
117 SECTION FC 512 ROOFTOP SOLAR PANEL INSTALLATIONS
120 CHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION FC 601GENERAL
SECTION FC 602 DEFINITIONS
SECTION FC 603 FUEL-FIRED APPLIANCES AND EQUIPMENT
122 SECTION FC 604 EMERGENCY POWER SYSTEMS
123 SECTION FC 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
124 SECTION FC 606 REFRIGERATING SYSTEMS
126 FC TABLE 606.1.1 REFRIGERATING SYSTEM OPERATING ENGINEER
127 SECTION FC 607 ELEVATORS IN READINESS
SECTION FC 608 STATIONARY ENERGY STORAGE SYSTEMS
129 FC TABLE 608.9.1.1 MAXIMUM AGGREGATE RATED ENERGY CAPACITY OF INDOOR STATIONARY ENERGY STORAGE SYSTEMS
132 SECTION FC 609 COMMERCIAL COOKING SYSTEMS
135 FC TABLE 609.5.3.1 COMMERCIAL COOKING EXHAUST SYSTEM INSPECTION
FC TABLE 609.5.3.3 COMMERCIAL COOKING EXHAUST SYSTEM CLEANING
137 FC TABLE 609.7 COMMERCIAL COOKING FIRE EXTINGUISHING AND EXHAUST SYSTEM SIGNAGE
SECTION FC 610 COMMERCIAL KITCHEN COOKING OIL STORAGE SYSTEMS
138 SECTION FC 611 AUTOMATED PARKING GARAGES
140 CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION FC 701 GENERAL
SECTION FC 702 DEFINITIONS
SECTION FC 703 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION FC 704 FLOOR OPENINGS AND SHAFTS
142 CHAPTER 8 INTERIOR FURNISHINGS, DECORATIONS AND SCENERY
SECTION FC 801 GENERAL
SECTION FC 802 DEFINITIONS
SECTION FC 803 UPHOLSTERED FURNITURE AND MATTRESSES
143 SECTION FC 804 DECORATIVE VEGETATION
144 SECTION FC 805 DECORATIONS AND SCENERY
145 SECTION FC 806 INTERIOR FINISHES
146 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION FC 901 GENERAL
147 FC TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
150 SECTION FC 902 DEFINITIONS
151 SECTION FC 903 SPRINKLER SYSTEMS
152 FC TABLE 903.2.13 ADDITIONAL REQUIRED FIRE EXTINGUISHING SYSTEMS
153 FC TABLE 903.2.13—continued ADDITIONAL REQUIRED FIRE EXTINGUISHING SYSTEMS
155 SECTION FC 904 FIRE EXTINGUISHING SYSTEMS
FC TABLE 904.1 FIRE EXTINGUISHING SYSTEM REFERENCED STANDARDS
160 FC TABLE 904.5.2 FIRE EXTINGUISHING SYSTEM INSPECTION, TESTING AND MAINTENANCE SCHEDULE
161 SECTION FC 905 STANDPIPE SYSTEMS
162 SECTION FC 906 PORTABLE FIRE EXTINGUISHERS
163 FC TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
164 FC TABLE 906.1—continued ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
165 FC TABLE 906.3.1 PORTABLE FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
FC TABLE 906.3.2 FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCHa
SECTION FC 907 FIRE ALARM AND DETECTION SYSTEMS
167 SECTION FC 908 EMERGENCY ALARM SYSTEMS
168 FC TABLE 908.1 REQUIRED EMERGENCY ALARMS
SECTION FC 909 SMOKE CONTROL SYSTEMS
169 SECTION FC 910 SMOKE AND HEAT VENTS
SECTION FC 911 EXPLOSION CONTROL
170 FC TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS
SECTION FC 912 FIRE DEPARTMENT CONNECTIONS
171 SECTION FC 913 FIRE PUMPS
172 SECTION FC 914 YARD HYDRANT SYSTEMS
174 CHAPTER 10 MEANS OF EGRESS
SECTION FC 1001 GENERAL
SECTION FC 1002 DEFINITIONS
SECTIONS FC 1003 THROUGH AND INCLUDING SECTION FC 1024RESERVED
SECTION FC 1025 EMERGENCY ESCAPE AND RESCUE
SECTION FC 1026 RESERVED
SECTION FC 1027 MAINTENANCE OF THE MEANS OF EGRESS
178 CHAPTERS 11 THROUGH 19 RESERVED
180 CHAPTER 20 AVIATION FACILITIES AND OPERATIONS
SECTION FC 2001 GENERAL
SECTION FC 2002 DEFINITIONS
SECTION FC 2003 GENERAL PRECAUTIONS
SECTION FC 2004 AIRCRAFT MAINTENANCE
181 SECTION FC 2005 PORTABLE FIRE EXTINGUISHERS
SECTION FC 2006 AIRCRAFT AND MOTOR VEHICLE FUELING
185 SECTION FC 2007 HELISTOPS AND HELIPORTS
186 SECTION FC 2008 SEAPLANE BASE OPERATIONS
SECTION FC 2009 HELICOPTER LANDING OPERATIONS
SECTION FC 2010 HELICOPTER LIFT OPERATIONS
187 SECTION FC 2011 HOT AIR BALLOON OPERATIONS
190 CHAPTER 21 DRY CLEANING
SECTION FC 2101 GENERAL
SECTION FC 2102 DEFINITIONS
SECTION FC 2103 CLASSIFICATIONS
191 SECTION FC 2104 GENERAL REQUIREMENTS
SECTION FC 2105 OPERATING AND MAINTENANCE REQUIREMENTS
192 SECTION FC 2106 SPOTTING AND PRETREATING
SECTION FC 2107 DRY CLEANING SYSTEMS
193 SECTION FC 2108 FIRE PROTECTION
194 CHAPTER 22 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION FC 2201 GENERAL
SECTION FC 2202 DEFINITIONS
SECTION FC 2203 PRECAUTIONS
SECTION FC 2204 ADDITIONAL REQUIREMENTS
FC TABLE 2204.1 EXPLOSION PROTECTION STANDARDS
196 CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION FC 2301 GENERAL
SECTION FC 2302 DEFINITIONS
197 SECTION FC 2303 LOCATION OF LIQUID MOTOR FUEL DISPENSING DEVICES
SECTION FC 2304 DISPENSING OF LIQUID MOTOR FUEL
199 SECTION FC 2305 OPERATION AND MAINTENANCE OF LIQUID MOTOR FUEL-DISPENSING FACILITIES
200 SECTION FC 2306 DESIGN AND INSTALLATION REQUIREMENTS FOR LIQUID MOTOR FUEL-DISPENSING FACILITIES
201 FC TABLE 2306.2.4 MINIMUM SEPARATION REQUIREMENTS FOR ABOVEGROUND TANKS AT FLEET MOTOR FUEL-DISPENSING FACILITIES
207 SECTION FC 2307 DESIGN AND INSTALLATION REQUIREMENTS FOR BIODIESEL MOTOR FUEL
SECTION FC 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
211 FC TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION FC 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATING FACILITIES
213 SECTION FC 2310 MARINE LIQUID MOTOR FUEL-DISPENSING FACILITIES
215 SECTION FC 2311 REPAIR GARAGES
218 CHAPTER 24 FLAMMABLE FINISHES
SECTION FC 2401 GENERAL
SECTION FC 2402 DEFINITIONS
SECTION FC 2403 PROTECTION OF OPERATIONS
220 SECTION FC 2404 SPRAY FINISHING
222 SECTION FC 2405 DIP-TANK OPERATIONS
224 SECTION FC 2406 POWDER COATING
SECTION FC 2407 ELECTROSTATIC SPRAY-FINISHING EQUIPMENT
225 SECTION FC 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
226 SECTION FC 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS
227 SECTION FC 2410 FLOOR FINISHING OPERATIONS
228 CHAPTER 25 FRUIT AND CROP RIPENING
SECTION FC 2501 GENERAL
SECTION FC 2502 DEFINITIONS
SECTION FC 2503 ETHYLENE GAS
SECTION FC 2504 SOURCES OF IGNITION
SECTION FC 2505 COMBUSTIBLE WASTE
SECTION FC 2506 ETHYLENE GENERATORS
SECTION FC 2507 WARNING SIGNS
230 CHAPTER 26 FUMIGATION AND INSECTICIDAL FOGGING
SECTION FC 2601 GENERAL
SECTION FC 2602 DEFINITIONS
SECTION FC 2603 FIRE SAFETY REQUIREMENTS
232 CHAPTER 27 SEMICONDUCTOR FABRICATION FACILITIES
SECTION FC 2701 GENERAL
SECTION FC 2702 DEFINITIONS
SECTION FC 2703 GENERAL SAFETY PROVISIONS
235 SECTION FC 2704 STORAGE
236 FC TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
237 FC TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
SECTION FC 2705 HANDLING AND USE
238 FC TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd
240 CHAPTER 28 LUMBER YARDS AND WOOD WASTE MATERIALS
SECTION FC 2801 GENERAL
SECTION FC 2802 DEFINITIONS
SECTION FC 2803 GENERAL REQUIREMENTS
SECTION FC 2804 THROUGH AND INCLUDING SECTION 2807 RESERVED
SECTION FC 2808 OUTDOOR STORAGE OF WOOD CHIPS AND OTHER WOOD WASTE MATERIALS
241 SECTION FC 2809 OUTDOOR STORAGE OF FINISHED LUMBER PRODUCTS
242 CHAPTER 29 MANUFACTURE OF ORGANIC COATINGS
SECTION FC 2901 GENERAL
SECTION FC 2902 DEFINITIONS
SECTION FC 2903 GENERAL PRECAUTIONS
SECTION FC 2904 ELECTRICAL EQUIPMENT AND PROTECTION
243 SECTION FC 2905 PROCESS STRUCTURES
SECTION FC 2906 PROCESS MILLS AND KETTLES
SECTION FC 2907 PROCESS PIPING
244 SECTION FC 2908 RAW MATERIALS IN PROCESS AREAS
SECTION FC 2909 RAW MATERIALS AND FINISHED PRODUCTS
246 CHAPTER 30 INDUSTRIAL FURNACES
SECTION FC 3001 GENERAL
SECTION FC 3002 DEFINITIONS
SECTION FC 3003 LOCATION
SECTION FC 3004 FUEL PIPING
SECTION FC 3005 INTERLOCKS
SECTION FC 3006 FIRE PROTECTION
SECTION FC 3007 OPERATION AND MAINTENANCE
248 CHAPTER 31 TENTS AND OTHER MEMBRANE STRUCTURES
SECTION FC 3101 GENERAL
SECTION FC 3102 DEFINITIONS
SECTION FC 3103 RESERVED
SECTION FC 3104 TENTS AND OTHER MEMBRANE STRUCTURES
252 CHAPTER 32 HIGH-PILED COMBUSTIBLE STORAGE
SECTION FC 3201 GENERAL
SECTION FC 3202 DEFINITIONS
253 SECTION FC 3203 COMMODITY CLASSIFICATION
255 FC FIGURE 3203.7.4 MIXED COMMODITIES
256 SECTION FC 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS
SECTION FC 3205 HOUSEKEEPING AND MAINTENANCE
SECTION FC 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
257 FC TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
258 SECTION FC 3207 SOLID-PILED AND SHELF STORAGE
259 SECTION FC 3208 RACK STORAGE
FC TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE
260 SECTION FC 3209 AUTOMATED STORAGE
SECTION FC 3210 RECORD STORAGE
262 CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION
SECTION FC 3301 GENERAL
SECTION FC 3302 DEFINITIONS
SECTION FC 3303 PORTABLE FUELED SPACE HEATERS
SECTION FC 3304 PRECAUTIONS AGAINST FIRE
263 SECTION FC 3305 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION FC 3306 FLAMMABLE GASES AND OXYGEN
265 SECTION FC 3307 EXPLOSIVE MATERIALS
SECTION FC 3308 CONSTRUCTION SITE FIRE SAFETY MANAGER
266 SECTION FC 3309 FIRE ALARM REPORTING
SECTION FC 3310 ACCESS FOR FIREFIGHTING
SECTION FC 3311 MEANS OF EGRESS AND ELEVATORS
SECTION FC 3312 WATER SUPPLY FOR FIRE PROTECTION
SECTION FC 3313 STANDPIPES
SECTION FC 3314 SPRINKLER SYSTEM
267 SECTION FC 3315 PORTABLE FIRE EXTINGUISHERS
SECTION FC 3316 INTERNAL-COMBUSTION-POWERED EQUIPMENT
SECTION FC 3317 SAFEGUARDING ROOFING OPERATIONS
SECTION FC 3318 POWDER-ACTUATED TOOL LOADS
SECTION FC 3319 FIRST RESPONDER BOX
268 CHAPTER 34 TIRE REBUILDING AND TIRE STORAGE
SECTION FC 3401 GENERAL
SECTION FC 3402 DEFINITIONS
SECTION FC 3403 TIRE REBUILDING
SECTION FC 3404 PRECAUTIONS AGAINST FIRE
SECTION FC 3405 OUTDOOR STORAGE
269 SECTION FC 3406 FIRE DEPARTMENT ACCESS
SECTION FC 3407 FENCING
SECTION FC 3408 FIRE PROTECTION
SECTION FC 3409 INDOOR STORAGE ARRANGEMENT
270 CHAPTER 35 WELDING AND OTHER HOT WORK
SECTION FC 3501 GENERAL
SECTION FC 3502 DEFINITIONS
SECTION FC 3503 GENERAL REQUIREMENTS
271 SECTION FC 3504 FIRE SAFETY REQUIREMENTS
273 SECTION FC 3505 GAS WELDING AND CUTTING
274 SECTION FC 3506 ELECTRIC ARC HOT WORK
SECTION FC 3507 RESERVED
SECTION FC 3508 RESERVED
SECTION FC 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
SECTION FC 3510 HOT WORK ON FLAMMABLE AND COMBUSTIBLE LIQUID STORAGE TANKS
276 CHAPTER 36 MARINAS
SECTION FC 3601 GENERAL
SECTION FC 3602 DEFINITIONS
SECTION FC 3603 GENERAL PRECAUTIONS
SECTION FC 3604 MARINA OPERATIONS
277 SECTION FC 3605 FIRE PROTECTION, EQUIPMENT AND ACCESS
280 CHAPTER 37 COMBUSTIBLE FIBERS
SECTION FC 3701 GENERAL
SECTION FC 3702 DEFINITIONS
SECTION FC 3703 GENERAL REQUIREMENTS
SECTION FC 3704 LOOSE FIBER STORAGE
281 SECTION FC 3705 BALED STORAGE
SECTION FC 3706 STORAGE OF COMBUSTIBLE FIBERS ON WATERFRONT STRUCTURES
284 CHAPTERS 38 and 39 RESERVED
286 CHAPTER 40 DISTILLERIES
SECTION FC 4001 GENERAL
287 SECTION FC 4002 DEFINITIONS
SECTION FC 4003 DESIGN AND INSTALLATION REQUIREMENTS FOR DISTILLERY FACILITIES
288 FC TABLE 4003.3 MAXIMUM STILL CAPACITIES AND MAXIMUM ALLOWABLE QUANTITIES
290 SECTION FC 4004 DESIGN AND INSTALLATION REQUIREMENTS FOR DISTILLERY EQUIPMENT
SECTION FC 4005 STORAGE OF ALCOHOL IN DISTILLERIES
291 SECTION FC 4006 OPERATIONAL AND MAINTENANCE REQUIREMENTS FOR DISTILLERIES
292 SECTION FC 4007 OTHER ALCOHOL PRODUCTION
294 CHAPTERS 41 THROUGH 49 RESERVED
296 CHAPTER 50 HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION FC 5001 GENERAL
297 SECTION FC 5002 DEFINITIONS
298 SECTION FC 5003 GENERAL REQUIREMENTS
299 FC TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa
300 FC TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa
301 FC TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa
302 FC TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
303 FC TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA
304 FC TABLE 5003.1.1(3)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL
FC TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREA
308 FC TABLE 5003.8.2 REQUIRED DETACHED STORAGE
309 FC TABLE 5003.8.3.3 DESIGN AND NUMBER OF CONTROL AREAS
312 FC TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
313 SECTION FC 5004 STORAGE
314 FC TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
316 SECTION FC 5005 HANDLING AND USE
318 FC TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS USE
320 SECTION FC 5006 NON-PRODUCTION CHEMICAL LABORATORIES
322 SECTION FC 5007 TRANSPORTATION OF HAZARDOUS MATERIALS
326 CHAPTER 51 AEROSOLS
SECTION FC 5101 GENERAL
SECTION FC 5102 DEFINITIONS
SECTION FC 5103 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION FC 5104 INDOOR STORAGE OF AEROSOL PRODUCTS
327 FC TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb
FC TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
328 FC TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
FC TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOLPRODUCTS IN RETAIL STORAGE AREAS
329 SECTION FC 5105 OUTDOOR STORAGE
FC TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTDOOR STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
SECTION FC 5106 RETAIL DISPLAY
FC TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS
330 FC TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND LEVEL 3 AEROSOLS
332 CHAPTER 52 RESERVED
334 CHAPTER 53 COMPRESSED GASES
SECTION FC 5301 GENERAL
SECTION FC 5302 DEFINITIONS
SECTION FC 5303 GENERAL REQUIREMENTS
337 SECTION FC 5304 STORAGE OF COMPRESSED GASES
SECTION FC 5305 HANDLING AND USE OF COMPRESSED GASES
SECTION FC 5306 MEDICAL GAS STORAGE
338 SECTION FC 5307 CARBON DIOXIDE BEVERAGE DISPENSING SYSTEMS
339 SECTION FC 5308 ETHYLENE OXIDE
340 SECTION FC 5309 COMPRESSED GASES NOT OTHERWISE REGULATED
342 CHAPTER 54 CORROSIVE MATERIALS
SECTION FC 5401 GENERAL
SECTION FC 5402 DEFINITIONS
SECTION FC 5403 GENERAL REQUIREMENTS
SECTION FC 5404 STORAGE
SECTION FC 5405 HANDLING AND USE
344 CHAPTER 55 CRYOGENIC FLUIDS
SECTION FC 5501 GENERAL
SECTION FC 5502 DEFINITIONS
SECTION FC 5503 GENERAL REQUIREMENTS
346 SECTION FC 5504 STORAGE
347 FC TABLE 5504.3.1.1 SEPARATION OF STATIONARY CRYOGENIC CONTAINERS FROM EXPOSURE HAZARDS
FC TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CRYOGENIC CONTAINERS FROM EXPOSURE HAZARDS
348 SECTION FC 5505 HANDLING AND USE
349 SECTION FC 5506 LNG INSTALLATIONS AND FACILITIES
350 CHAPTER 56 EXPLOSIVES, FIREWORKS AND SPECIAL EFFECTS
SECTION FC 5601 GENERAL
355 SECTION FC 5602 DEFINITIONS
356 SECTION FC 5603 EXPLOSIVES RECORDKEEPING AND REPORTING
357 SECTION FC 5604 EXPLOSIVES STORAGE AND HANDLING
359 FC TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
360 FC TABLE 5604.5.2(1) APPLICATION OF SEPARATION DISTANCE TABLE
TABLE 5604.5.2(2) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES (AS REVISED JUNE 1991)
361 FC TABLE 5604.5.2(3) TABLE OF DISTANCES FOR OUTDOOR MAGAZINES OR BUILDINGS CONTAINING EXPLOSIVES— DIVISION 1.3— MASS-FIRE HAZARD
FC TABLE 5604.5.2(4) TABLE OF DISTANCES FOR OUTDOOR MAGAZINES OR BUILDINGS CONTAINING EXPLOSIVES – DIVISION 1.4
363 SECTION FC 5605 RESERVED
SECTION FC 5606 SMALL ARMS AMMUNITION, POWDER-ACTUATED TOOL LOADS, BLACK POWDER AND SMOKELESSPROPELLANTS
365 SECTION FC 5607 BLASTING OPERATIONS
371 FC TABLE 5607.19.1 MAXIMUM ALLOWABLE GROUND VIBRATIONS FROM BLASTING OPERATIONS
373 SECTION FC 5608 FIREWORKS DISPLAYS
375 FC TABLE 5608.4.1 ONSHORE DISPLAYS
FC TABLE 5608.4.2 OFFSHORE DISPLAYS
379 SECTION FC 5609 SPECIAL EFFECTS
384 CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION FC 5701 GENERAL
385 SECTION FC 5702 DEFINITIONS
SECTION FC 5703 GENERAL REQUIREMENTS
386 FC TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONS
387 FC TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONS
388 FC TABLE 5703.6.2 PIPING STANDARDS
389 SECTION FC 5704 STORAGE
399 FC TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES USES PER CONTROL AREA
400 FC TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREAS
FC TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
401 FC TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
FC TABLE 5704.3.6.3(4) SPRINKLER SYSTEM PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS
402 FC TABLE 5704.3.6.3(5) SPRINKLER SYSTEM PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETS
403 FC TABLE 5704.3.6.3(5) SPRINKLER SYSTEM PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETS
404 FC TABLE 5704.3.6.3(6) SPRINKLER SYSTEM PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
405 FC TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
FC TABLE 5704.3.6.3(8) SPRINKLER SYSTEM PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAY
407 FC TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS
408 FC TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS
409 SECTION FC 5705 HANDLING AND USE
410 FC TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
FC TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH FC TABLE 5705.3.4
412 FC TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OFFLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOORCONTROL AREAS
414 SECTION FC 5706 SPECIAL OPERATIONS
416 FC TABLE 5706.4.5.1 DISTANCE BETWEEN AN ABOVE GROUND STORAGE TANKAND LOT LINES
417 FC TABLE 5706.4.5.2 DISTANCE BETWEEN ABOVEGROUND STORAGE TANKS
421 FC TABLE 5706.4.13.1 OIL SPILL MATERIALS AND EQUIPMENT TO BE STORED AT EACH BULK PLANT AND TERMINAL OR PIPELINE
426 SECTION FC 5707 FLEET FUELING OPERATIONS
428 CHAPTER 58 FLAMMABLE GASES
SECTION FC 5801 GENERAL
SECTION FC 5802 DEFINITIONS
SECTION FC 5803 GENERAL REQUIREMENTS
429 SECTION FC 5804 STORAGE
430 SECTION FC 5805 USE
SECTION FC 5806 ETHYLENE OXIDE
FC TABLE 5804.2.1 FLAMMABLE GASES DISTANCE FROM OUTDOOR STORAGE AREAS TO EXPOSURES
432 FC TABLE 5806.3.6 MAXIMUM NUMBER OF ETHYLENE OXIDE CONTAINERS NOT EXCEEDING 3 GALLON LIMIT
SECTION FC 5807 METAL HYDRIDE HYDROGEN STORAGE SYSTEMS
433 SECTION FC 5808 HYDROGEN FUEL GAS ROOMS
SECTION FC 5809 METHANE RECOVERY FROM LANDFILLS
SECTION FC 5810 MICROTURBINES
434 SECTION FC 5811 COMPRESSED NATURAL GAS
436 CHAPTER 59 FLAMMABLE SOLIDS
SECTION FC 5901 GENERAL
SECTION FC 5902 DEFINITIONS
SECTION FC 5903 GENERAL REQUIREMENTS
SECTION FC 5904 STORAGE
SECTION FC 5905 HANDLING AND USE
438 CHAPTER 60 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION FC 6001 GENERAL
SECTION FC 6002 DEFINITIONS
SECTION FC 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
439 SECTION FC 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
443 SECTION FC 6005 OZONE GAS GENERATORS
446 CHAPTER 61 LIQUEFIED PETROLEUM GASES
SECTION FC 6101 GENERAL
SECTION FC 6102 DEFINITIONS
SECTION FC 6103 INSTALLATION OF EQUIPMENT
447 SECTION FC 6104 RESERVED
SECTION FC 6105 PROHIBITED STORAGE, HANDLING AND USE OF LPG
448 SECTION FC 6106 DISPENSING AND FILLING
SECTION FC 6107 SAFETY PRECAUTIONS AND DEVICES
SECTION FC 6108 PORTABLE FIRE EXTINGUISHERS
SECTION FC 6109 STORAGE OF PORTABLE LPG CONTAINERS
449 FC TABLE 6109.12 DISTANCES FROM OUTDOOR LPG STORAGE AREA TO EXPOSURES
452 CHAPTER 62 ORGANIC PEROXIDES
SECTION FC 6201 GENERAL
SECTION FC 6202 DEFINITIONS
SECTION FC 6203 GENERAL REQUIREMENTS
SECTION FC 6204 STORAGE
453 FC TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS TO EXPOSURES
454 FC TABLE 6204.2.4 STORAGE REQUIREMENTS FOR ORGANIC PEROXIDES
SECTION FC 6205 HANDLING AND USE
SECTION FC 6206 MANUFACTURING RESTRICTIONS
456 CHAPTER 63 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
SECTION FC 6301 GENERAL
SECTION FC 6302 DEFINITIONS
SECTION FC 6303 GENERAL REQUIREMENTS
457 SECTION FC 6304 STORAGE
FC TABLE 6304.1.2 OXIDIZER (LIQUIDS AND SOLIDS)—DISTANCE FROM DETACHED STORAGE BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES
458 FC TABLE 6304.1.7(1) STORAGE REQUIREMENTS FOR CLASS 1 OXIDIZER (LIQUIDS AND SOLIDS) IN COMBUSTIBLE CONTAINERS
FC TABLE 6304.1.7(2) STORAGE REQUIREMENTS FOR CLASS 2 OXIDIZER (LIQUIDS AND SOLIDS
FC TABLE 6304.1.7(3) STORAGE REQUIREMENTS FOR CLASS 3 OXIDIZER (LIQUIDS AND SOLIDS
FC TABLE 6304.1.7(4) STORAGE REQUIREMENTS FOR CLASS 4 OXIDIZER (LIQUIDS AND SOLIDS)
459 FC TABLE 6304.2.2 OXIDIZING GASES—DISTANCE FROM STORAGE TO EXPOSURES
FC TABLE 6304.2.2 OXIDIZING GASES—DISTANCE FROM STORAGE TOEXPOSURES
SECTION FC 6305 HANDLING AND USE
SECTION FC 6306 LIQUID OXYGEN FOR RESIDENTIAL HEALTH CAREUSE
460 SECTION FC 6307 MANUFACTURING RESTRICTIONS
462 CHAPTER 64 PYROPHORIC MATERIALS
SECTION FC 6401 GENERAL
SECTION FC 6402 DEFINITIONS
SECTION FC 6403 GENERAL REQUIREMENTS
SECTION FC 6404 STORAGE
463 FC TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURES
SECTION FC 6405 HANDLING AND USE
SECTION FC 6406 MANUFACTURING RESTRICTIONS
464 CHAPTER 65 PYROXYLIN PLASTICS
SECTION FC 6501 GENERAL
SECTION FC 6502 DEFINITIONS
SECTION FC 6503 GENERAL REQUIREMENTS
SECTION FC 6504 STORAGE, HANDLING AND USE
465 SECTION FC 6505 MANUFACTURING RESTRICTIONS
466 CHAPTER 66 UNSTABLE (REACTIVE) MATERIALS
SECTION FC 6601 GENERAL
SECTION FC 6602 DEFINITIONS
SECTION FC 6603 GENERAL REQUIREMENTS
SECTION 6604 STORAGE
467 SECTION FC 6605 HANDLING AND USE
SECTION FC 6606 MANUFACTURING RESTRICTIONS
468 CHAPTER 67 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION FC 6701 GENERAL
SECTION FC 6702 DEFINITIONS
SECTION FC 6703 GENERAL REQUIREMENTS
SECTION FC 6704 STORAGE
469 SECTION FC 6705 HANDLING AND USE
SECTION FC 6706 MANUFACTURING RESTRICTIONS
470 CHAPTERS 68 THROUGH 79 RESERVED
472 CHAPTER 80 REFERENCED STANDARDS
SECTION FC 8001 GENERAL
SECTION FC 8002 LIST OF REFERENCED STANDARDS
ANSI
API
ASHRAE
473 ASME
ASTM
CA
474 CGA
CGR
CPSC
DOC
DOJ
475 DOL
DOTn
EN
EPA
FM
476 IIAR
IKECA
ISO
NEMA
477 NFPA
478 UL
480 APPENDIX A FEES
SECTION FC A01 CERTIFICATES
482 SECTION FC A02 TRAINING SCHOOLS
483 SECTION FC A03 PERMITS, INSPECTIONS AND PLAN EXAMINATIONS
497 SECTION FC A04 ADMINISTRATIVE SERVICES
SECTION FC A05 LATE RENEWALS
498 APPENDIX B REFERENCED STANDARD MODIFICATIONS
SECTION FC B01 NATIONAL FIRE PROTECTION ASSOCIATION REFERENCED STANDARDS
507 Table 7.2 Road Tunnel Fire Protection Summary
514 INDEX
552 ICC DIGITAL CODES PREMIUM
553 ICC ASSESSMENT CENTER
554 ICC LEARNING CENTER
555 ICC EVALUATION SERVICE
]]>
NY NYC MechanicalCode 2022 1stptg ?u=/product/publishers/ny/ny-nyc-mechanicalcode-2022-1stptg/ Sun, 20 Oct 2024 06:12:41 +0000 New York City Mechanical Code
Published By Publication Date Number of Pages
NY 2022
]]>
This is a fully integrated custom code based on the 2015 International Mechanical Code. Effective date: November 7, 2022.

PDF Catalog

PDF Pages PDF Title
1 2022 NEW YORK CITY MECHANICAL CODE
2 2022 NEW YORK CITY MECHANICAL CODE TITLE PAGE
3 COPYRIGHT
4 DEDICATION
6 NEW YORK CITY CONSTRUCTION CODES PREFACE
8 ACKNOWLEDGEMENTS
16 TITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES
18 TITLE 28 NEW YORK CITY CONSTRUCTION CODES
20 TABLE OF CONTENTS
24 CHAPTER 1 ADMINISTRATION
SECTION MC 101 GENERAL
SECTION MC 102 APPLICABILITY
25 SECTION MC 103 DEPARTMENT OF BUILDINGS
SECTION MC 104 DUTIES AND POWERS OF THE COMMISSIONER OF BUILDINGS
SECTION MC 105 APPROVALS
SECTION MC 106 PERMITS
SECTION MC 107 CONSTRUCTION DOCUMENTS
27 SECTION MC 108 INSPECTIONS AND TESTING
28 SECTION MC 109 VIOLATIONS
30 CHAPTER 2 DEFINITIONS
SECTION MC 201 GENERAL
31 SECTION MC 202 GENERAL DEFINITIONS
44 CHAPTER 3 GENERAL REGULATIONS
SECTION MC 301 GENERAL
45 SECTION MC 302 STRUCTURAL SAFETY
46 SECTION MC 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION MC 304 INSTALLATION
47 SECTION MC 305 PIPING SUPPORT
48 TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION MC 306 ACCESS AND SERVICE SPACE
50 SECTION MC 307 CONDENSATE DISPOSAL
51 TABLE 307.2.2 CONDENSATE DRAIN SIZING
SECTION MC 308 CLEARANCE REDUCTION
52 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
53 SECTION MC 309 TEMPERATURE CONTROL
SECTION MC 310 EXPLOSION CONTROL
SECTION MC 311 SMOKE AND HEAT VENTS
SECTION MC 312 HEATING AND COOLING LOAD CALCULATIONS
SECTION MC 313 NOISE CONTROL AND VIBRATION ISOLATION REQUIREMENTS
56 CHAPTER 4 VENTILATION
SECTION MC 401 GENERAL
57 TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING OUTDOOR EXHAUST AND AIR INTAKE OPENINGS
SECTION MC 402 NATURAL VENTILATION
SECTION MC 403 MECHANICAL VENTILATION
58 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
59 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
60 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
61 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
62 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
63 EQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5
64 TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
EQUATION 4-9
65 SECTION MC 404 ENCLOSED PARKING GARAGES
SECTION MC 405 SYSTEMS CONTROL
SECTION MC 406 VENTILATION OF UNINHABITED SPACES
SECTION MC 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
SECTION MC 408 VENTILATION OF NONPRODUCTION CHEMICAL LABORATORIES
66 CHAPTER 5 EXHAUST SYSTEMS
SECTION MC 501 GENERAL
67 SECTION MC 502 REQUIRED SYSTEMS
68 EQUATION 5-1
75 SECTION MC 503 MOTORS AND FANS
SECTION MC 504 CLOTHES DRYER EXHAUST
76 TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
77 SECTION MC 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION MC 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
83 SECTION MC 507 COMMERCIAL KITCHEN HOODS
85 TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
86 SECTION MC 508 COMMERCIAL KITCHEN MAKEUP AIR
87 SECTION MC 509 FIRE SUPPRESSION SYSTEMS
SECTION MC 510 HAZARDOUS EXHAUST SYSTEMS
89 TABLE 510.9 MINIMUM DUCT THICKNESS
TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
SECTION MC 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
90 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL DUST, STOCK AND REFUSE CONVEYING SYSTEMS
SECTION MC 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION MC 513 SMOKE CONTROL SYSTEMS
91 SECTION MC 514 ENERGY RECOVERY VENTILATION SYSTEMS
SECTION MC 515 POSTFIRE SMOKE PURGE SYSTEMS
92 CHAPTER 6 DUCT SYSTEMS
SECTION MC 601 GENERAL
93 SECTION MC 602 PLENUMS
94 SECTION MC 603 DUCT CONSTRUCTION AND INSTALLATION
95 TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa
97 SECTION MC 604 INSULATION
98 SECTION MC 605 AIR FILTERS
SECTION MC 606 SMOKE DETECTION SYSTEMS CONTROL
99 SECTION MC 607 DUCTS AND AIR TRANSFER OPENINGS
100 TABLE 607.3.2.1 FIRE DAMPER RATING
106 SECTION MC 608 AIR OUTLETS AND AIR INLETS
SECTION MC 609 SERVICE OPENINGS
108 CHAPTER 7 COMBUSTION, VENTILATION, AND DILUTION AIR
SECTION MC 701 GENERAL
SECTION MC 702 INSIDE AIR
109 SECTION MC 703 OUTDOOR AIR
SECTION MC 704 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 1)
110 SECTION MC 705 COMBINED USE OF INSIDE AND OUTDOOR AIR (CONDITION 2)
SECTION MC 706 MECHANICAL COMBUSTION AIR SUPPLY
SECTION MC 707 DIRECT CONNECTION
SECTION MC 708 COMBUSTION AIR DUCTS
SECTION MC 709 OPENING OBSTRUCTIONS
111 SECTION MC 710 OPENING LOCATION AND PROTECTION
112 CHAPTER 8 CHIMNEYS AND VENTS
SECTION MC 801 GENERAL
116 EQUATION 8-1
TABLE 801.21 “F” FACTOR FOR DETERMINING CHIMNEY DISTANCES
SECTION MC 802 VENTS
117 TABLE 802.2 VENT APPLICATION
SECTION MC 803 CONNECTORS
TABLE 803.8 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
118 TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
119 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION MC 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
121 SECTION MC 805 FACTORY-BUILT CHIMNEYS
SECTION MC 806 METAL CHIMNEYS
SECTION MC 807 CHANGES IN APPLIANCE FUELS
SECTION MC 808 REDUCTION OF FLUE SIZE
SECTION MC 809 CHIMNEY SUPPORTED FROM EQUIPMENT
SECTION MC 810 TEST RUN AND SMOKE TEST
122 SECTION MC 811 EXHAUST GASES FROM INTERNAL COMBUSTION ENGINES AND TURBINES
124 CHAPTER 9 SPECIFIC APPLIANCES AND EQUIPMENT
SECTION MC 901 GENERAL
SECTION MC 902 MASONRY FIREPLACES
SECTION MC 903 FACTORY-BUILT FIREPLACES
SECTION MC 904 PELLET FUEL-BURNING APPLIANCES
SECTION MC 905 FIREPLACE STOVES AND ROOM HEATERS
125 SECTION MC 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION MC 907 INCINERATORS AND CREMATORIES
SECTION MC 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
126 SECTION MC 909 VENTED WALL FURNACES
SECTION MC 910 FLOOR FURNACES
127 SECTION MC 911 DUCT FURNACES AND HEATERS
SECTION MC 912 INFRARED RADIANT HEATERS
SECTION MC 913 CLOTHES DRYERS
SECTION MC 914 SAUNA HEATERS
128 SECTION MC 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION MC 916 POOL AND SPA HEATERS
SECTION MC 917 COOKING APPLIANCES
SECTION MC 918 FORCED-AIR WARM-AIR FURNACES
SECTION MC 919 CONVERSION BURNERS
SECTION MC 920 UNIT HEATERS
129 SECTION MC 921 VENTED ROOM HEATERS
SECTION MC 922 KEROSENE AND OIL-FIRED STOVES
SECTION MC 923 CERAMIC KILNS
SECTION MC 924 STATIONARY FUEL CELL POWER PLANTS
SECTION MC 925 MASONRY HEATERS
SECTION MC 926 GASEOUS HYDROGEN SYSTEMS
SECTION MC 927 ELECTRIC RADIANT HEATING SYSTEMS
SECTION MC 928 EVAPORATIVE COOLERS
132 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION MC 1001 GENERAL
SECTION MC 1002 WATER HEATERS
SECTION MC 1003 PRESSURE VESSELS
133 SECTION MC 1004 BOILERS
TABLE 1004.3.1 BOILER TOP CLEARANCES
134 SECTION MC 1005 BOILER CONNECTIONS
SECTION MC 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
135 SECTION MC 1007 BOILER LOW-WATER CUTOFF
SECTION MC 1008 BOILER BLOWOFF/BLOWDOWN VALVES
SECTION MC 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
136 TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
SECTION MC 1010 GAUGES
SECTION MC 1011 TESTS
137 SECTION MC 1012 MAXIMUM TEMPERATURE
138 CHAPTER 11 REFRIGERATION
SECTION MC 1101 GENERAL
SECTION MC 1102 SYSTEM REQUIREMENTS
139 SECTION MC 1103 REFRIGERATION SYSTEM CLASSIFICATION
TABLE 1103.1 REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
140 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
141 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
142 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
143 TABLE 1103.1—continued REFRIGERANT DATA AND SAFETY CLASSIFICATIONSa
SECTION MC 1104 SYSTEM APPLICATION REQUIREMENTS
145 TABLE 1104.3.1 SPECIAL QUANTITY LIMITS FOR SEALED AMMONIA/WATER ABSORPTION AND SELF-CONTAINED SYSTEMS
SECTION MC 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
146 EQUATION 11-1
EQUATION 11-2
147 SECTION MC 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
148 SECTION MC 1107 REFRIGERANT PIPING
150 SECTION MC 1108 FIELD TEST
151 SECTION MC 1109 PERIODIC TESTING
152 CHAPTER 12 HYDRONIC PIPING
SECTION MC 1201 GENERAL
SECTION MC 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4 HYDRONIC PIPE—continued
TABLE 1202.5 HYDRONIC PIPE FITTINGS
153 SECTION MC 1203 JOINTS AND CONNECTIONS
154 SECTION MC 1204 PIPE INSULATION
155 SECTION MC 1205 VALVES
SECTION MC 1206 PIPING INSTALLATION
SECTION MC 1207 TRANSFER FLUID
SECTION MC 1208 TESTS
156 SECTION MC 1209 EMBEDDED PIPING
SECTION MC 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
TABLE 1210.4 GROUND-SOURCE LOOP PIPE
TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
158 SECTION MC 1211 HIGH-PRESSURE STEAM AND HIGH TEMPERATURE HOT WATER PIPING SYSTEMS
162 CHAPTER 13 FUEL-OIL PIPING AND STORAGE
SECTION MC 1301 GENERAL
SECTION MC 1302 MATERIAL
TABLE 1302.3 FUEL-OIL PIPING
163 TABLE 1302.5 PIPE FITTINGS
SECTION MC 1303 JOINTS AND CONNECTIONS
164 SECTION MC 1304 PIPING SUPPORT
SECTION MC 1305 FUEL-OIL SYSTEM INSTALLATION
166 TABLE 1305.7(1) VENT PIPING FOR UNDERGROUND TANKS
TABLE 1305.7(2) NORMAL VENT PIPING FOR TANKS INSTALLED INSIDE BUILDINGS
172 EQUATION 13-1
173 EQUATION 13-2
174 SECTION MC 1306 OIL GAUGING
SECTION MC 1307 FUEL-OIL VALVES
175 SECTION MC 1308 TESTING
176 CHAPTER 14 SOLAR SYSTEMS
SECTION MC 1401 GENERAL
SECTION MC 1402 INSTALLATION
177 SECTION MC 1403 HEAT TRANSFER FLUIDS
SECTION MC 1404 MATERIALS
178 CHAPTER 15 REFERENCED STANDARDS
SECTION MC 1501 GENERAL
SECTION MC 1502 STANDARDS
ACCA
AHRI
AMCA
179 ANSI
ASHRAE
ASME
180 ASNT
ASSE
ASTM
182 AWS
AWWA
183 BSI
CAN/ULC
CSA
184 DOL
EN
IIAR
MSS
NAIMA
185 NBBI
NFPA
NSF
186 SMACNA
UL
188 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS
189 FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
190 APPENDIX B RESERVED
192 APPENDIX C FUEL OIL STORAGE TANK VENTING OPTIONS
SECTION MC C101 GENERAL
FIGURE C101.1(1) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK
193 FIGURE C101.1(2) PRIMARY TANK: UL 142 OR DUAL LABEL TANK DAY TANK: UL 142 OR DUAL LABEL TANK
194 FIGURE C101.1(3) PRIMARY TANK: UL 80, ASME BPVC, OR NYC ALTERNATE TANK DAY TANK: UL 142 OR DUAL LABEL TANK
196 INDEX RESERVED
198 ICC DIGITAL CODES PREMIUM
199 ICC ASSESSMENT CENTER
200 ICC LEARNING CENTER
201 ICC EVALUATION SERVICE
]]>
NY NYC PlumbingCode 2022 1stptg ?u=/product/publishers/ny/ny-nyc-plumbingcode-2022-1stptg/ Sun, 20 Oct 2024 06:12:41 +0000 New York City Plumbing Code
Published By Publication Date Number of Pages
NY 2022 189
]]>
The is a fully integrated custom code based on the 2015 International Plumbing Code. Effective date: November 7, 2022.

PDF Catalog

PDF Pages PDF Title
1 2022 NEW YORK CITY PLUMBING CODE
2 2022 NEW YORK CITY PLUMBING CODE TITLE PAGE
3 COPYRIGHT
4 DEDICATION
6 NEW YORK CITY CONSTRUCTION CODES PREFACE
8 ACKNOWLEDGEMENTS
16 TITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES
18 TITLE 28 NEW YORK CITY CONSTRUCTION CODES
20 TABLE OF CONTENTS
24 CHAPTER 1 ADMINISTRATION
SECTION PC 101 GENERAL
SECTION PC 102 APPLICABILITY
25 SECTION PC 103 DEPARTMENT OF BUILDINGS
SECTION PC 104 DUTIES AND POWERS OF THE COMMISSIONER OF BUILDINGS
SECTION PC 105 APPROVALS
SECTION PC 106 PERMITS
26 SECTION PC 107 CONSTRUCTION DOCUMENTS
29 SECTION PC 108 INSPECTIONS AND TESTING
30 SECTION PC 109 VIOLATIONS
32 CHAPTER 2 DEFINITIONS
SECTION PC 201 GENERAL
33 SECTION PC 202 GENERAL DEFINITIONS
42 CHAPTER 3 GENERAL REGULATIONS
SECTION PC 301 GENERAL
SECTION PC 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
SECTION PC 303 MATERIALS
SECTION PC 304 RODENTPROOFING
43 SECTION PC 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
SECTION PC 306 TRENCHING, EXCAVATION AND BACKFILL
44 SECTION PC 307 STRUCTURAL SAFETY
SECTION PC 308 PIPING SUPPORT
TABLE 308.5 HANGER SPACING
45 SECTION PC 309 FLOOD HAZARD RESISTANCE
SECTION PC 310 WASHROOM AND TOILET ROOM REQUIREMENTS
SECTION PC 311 TOILET FACILITIES FOR WORKERS
SECTION PC 312 TESTS AND INSPECTIONS
47 SECTION PC 313 EQUIPMENT EFFICIENCIES
SECTION PC 314 CONDENSATE DISPOSAL
48 TABLE 314.2.2 CONDENSATE DRAIN SIZING
49 SECTION PC 315 PENETRATIONS
SECTION PC 316 RESERVED
50 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION PC 401 GENERAL
SECTION PC 402 FIXTURE MATERIAL
SECTION PC 403 MINIMUM PLUMBING FACILITIES
51 TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
52 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
53 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2)
55 SECTION PC 404 ACCESSIBLE PLUMBING FACILITIES
SECTION PC 405 INSTALLATION OF FIXTURES
56 SECTION PC 406 AUTOMATIC CLOTHES WASHERS
57 SECTION PC 407 BATHTUBS
SECTION PC 408 BIDETS
SECTION PC 409 DISHWASHING MACHINES
SECTION PC 410 DRINKING FOUNTAINS
SECTION PC 411 EMERGENCY SHOWERS AND EYEWASH STATIONS
SECTION PC 412 FLOOR AND TRENCH DRAINS
SECTION PC 413 FOOD WASTE DISPOSER UNITS
58 SECTION PC 414 GARBAGE CAN WASHERS
SECTION PC 415 LAUNDRY TRAYS
SECTION PC 416 LAVATORIES
SECTION PC 417 SHOWERS
59 SECTION PC 418 SINKS
SECTION PC 419 URINALS
60 SECTION PC 420 WATER CLOSETS
SECTION PC 421 WHIRLPOOL BATHTUBS
SECTION PC 422 HEALTH CARE FIXTURES AND EQUIPMENT
61 SECTION PC 423 SPECIALTY PLUMBING FIXTURES
SECTION PC 424 FAUCETS AND OTHER FIXTURE FITTINGS
62 SECTION PC 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
SECTION PC 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION PC 427 FLOOR SINKS
SECTION PC 428 PROHIBITED WATER USES
63 SECTION PC 429 ROOFTOP GARDENS AND LANDSCAPING
64 CHAPTER 5 WATER HEATERS
SECTION PC 501 GENERAL
SECTION PC 502 INSTALLATION
65 SECTION PC 503 CONNECTIONS
SECTION PC 504 SAFETY DEVICES
66 SECTION PC 505 INSULATION
68 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION
SECTION PC 601 GENERAL
SECTION PC 602 WATER REQUIRED
69 SECTION PC 603 WATER SERVICE
SECTION PC 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
70 TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
71 TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
72 SECTION PC 605 MATERIALS, JOINTS AND CONNECTIONS
TABLE 605.4 WATER DISTRIBUTION PIPE
TABLE 605.4.1 UNDERGROUND WATER DISTRIBUTION PIPE
73 TABLE 605.5 PIPE FITTINGS
TABLE 605.7 VALVES
TABLE 605.8 MANUFACTURED PIPE NIPPLES
75 SECTION PC 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
TABLE 606.5.4 SIZE OF OVERFLOWS FOR GRAVITY AND SUCTION TANKS
76 FIGURE 606.5.4 METHODS OF CONNECTING OVERFLOW FROM GRAVITY HOUSE AND SUCTION WATER SUPPLY TANKS
77 TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION PC 607 HOT WATER SUPPLY SYSTEM
78 SECTION PC 608 PROTECTION OF POTABLE WATER SUPPLY
79 TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS
80 FIGURE 608.8.1 PICTOGRAPH—DO NOT DRINK
81 TABLE 608.8.2.2 SIZE OF PIPE IDENTIFICATION
82 TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS
84 TABLE 608.17.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES
SECTION PC 609 HEALTH CARE PLUMBING
85 SECTION PC 610 DISINFECTION OF POTABLE WATER SYSTEM
SECTION PC 611 DRINKING WATER TREATMENT UNITS
SECTION PC 612 SOLAR SYSTEMS
SECTION PC 613 TEMPERATURE CONTROL DEVICES AND VALVES
SECTION PC 614 EMERGENCY DRINKING WATER ACCESS
88 CHAPTER 7 SANITARY DRAINAGE
SECTION PC 701 GENERAL
SECTION PC 702 MATERIALS
89 TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING DRAIN PIPE
TABLE 702.4 PIPE FITTINGS
90 TABLE 702.4—continued PIPE FITTINGS
SECTION PC 703 BUILDING DRAIN
SECTION PC 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
91 FIGURE 704.6 SUDS PRESSURE ZONES
92 SECTION PC 705 JOINTS
94 TABLE 705.18 CAULKING FERRULE SPECIFICATIONS
TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS
SECTION PC 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
SECTION PC 707 PROHIBITED JOINTS AND CONNECTIONS
SECTION PC 708 CLEANOUTS
95 SECTION PC 709 FIXTURE UNITS
96 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
97 TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
SECTION PC 710 DRAINAGE SYSTEM SIZING
SECTION PC 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
SECTION PC 712 EJECTORS
98 TABLE 710.1(1) BUILDING DRAINS AND SEWERS
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa
99 TABLE 712.4.1 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
SECTION PC 713 HEALTH CARE PLUMBING
101 TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS
TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS
SECTION PC 714 COMPUTERIZED DRAINAGE DESIGN
SECTION PC 715 BACKWATER VALVES
102 SECTION PC 716 RESERVED
SECTION PC 717 RESERVED
104 CHAPTER 8 INDIRECT/SPECIAL WASTE
SECTION PC 801 GENERAL
SECTION PC 802 INDIRECT WASTES
105 SECTION PC 803 SPECIAL WASTES
TABLE 803.3.1 CHEMICAL WASTE AND VENT PIPE
TABLE 803.3.2 CHEMICAL WASTE AND VENT PIPE FITTINGS
106 SECTION PC 804 MATERIALS, JOINTS AND CONNECTIONS
108 CHAPTER 9 VENTS
SECTION PC 901 GENERAL
SECTION PC 902 MATERIALS
SECTION PC 903 VENT TERMINALS
SECTION PC 904 OUTDOOR VENT EXTENSIONS
109 SECTION PC 905 VENT CONNECTIONS AND GRADES
SECTION PC 906 VENT PIPE SIZING
110 TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
111 TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS
112 SECTION PC 907 VENTS FOR STACK OFFSETS
SECTION PC 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
SECTION PC 909 FIXTURE VENTS
TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
SECTION PC 910 INDIVIDUAL VENT
SECTION PC 911 COMMON VENT
113 TABLE 911.3 COMMON VENT SIZES
SECTION PC 912 WET VENTING
TABLE 912.3 WET VENT SIZE
SECTION PC 913 RESERVED
SECTION PC 914 CIRCUIT VENTING
114 SECTION PC 915 COMBINATION WASTE AND VENT SYSTEM
TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE
SECTION PC 916 ISLAND FIXTURE VENTING
SECTION PC 917 RESERVED
SECTION PC 918 RESERVED
SECTION PC 919 ENGINEERED VENT SYSTEMS
115 EQUATION 9-1
TABLE 919.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES
SECTION PC 920 COMPUTERIZED VENT DESIGN
116 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION PC 1001 GENERAL
SECTION PC 1002 TRAP REQUIREMENTS
117 SECTION PC 1003 INTERCEPTORS AND SEPARATORS
118 SECTION PC 1004 MATERIALS, JOINTS AND CONNECTIONS
120 CHAPTER 11 STORM DRAINAGE
SECTION PC 1101 GENERAL
121 FIGURE 1101.5.2.1(1) DETENTION VOLUME & TANK ABOVE GRADE (WITHIN BUILDING)
122 FIGURE 1101.5.2.1(2) DETENTION VOLUME ABOVE SEWER, TANK BELOW GRADE (WITHIN BUILDING)
123 FIGURE 1101.5.2.1(3) DETENTION VOLUME & TANK BELOW GRADE (WITHIN BUILDING)
124 SECTION PC 1102 MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
TABLE 1102.5 SUBSOIL DRAIN PIPE
125 TABLE 1102.7 PIPE FITTINGS
SECTION PC 1103 TRAPS
SECTION PC 1104 CONDUCTORS AND CONNECTIONS
SECTION PC 1105 ROOF DRAINS
126 SECTION PC 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
TABLE 1106.2 STORM DRAIN PIPE SIZING
TABLE 1106.3 VERTICAL LEADER SIZING
127 TABLE 1106.6 HORIZONTAL GUTTER SIZING
SECTION PC 1107 SIPHONIC ROOF DRAINAGE SYSTEMS
SECTION PC 1108 SECONDARY (EMERGENCY) ROOF DRAINS
SECTION PC 1109 COMBINED SANITARY AND STORM SYSTEM
128 SECTION PC 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
SECTION PC 1111 SUBSOIL DRAINS
SECTION PC 1112 BUILDING SUBDRAINS
SECTION PC 1113 SUMPS AND PUMPING SYSTEMS
SECTION PC 1114 PRIVATE ON-SITE STORMWATER DISPOSAL SYSTEMS
130 EQUATION 11-1
EQUATION 11-2
EQUATION 11-3
131 EQUATION 11-4
EQUATION 11-5
EQUATION 11-6
132 FIGURE 1114.4(1) GRIT CHAMBER
FIGURE 1114.4(2) DETAIL OF DRYWELL WITH SAND COLUMN
134 CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION PC 1201 GENERAL
SECTION PC 1202 MEDICAL AND NONMEDICAL GASES
SECTION PC 1203 NONMEDICAL OXYGEN SYSTEMS
SECTION PC 1204 OTHER CRYOGENIC SYSTEMS
136 CHAPTER 13 NONPOTABLE WATER SYSTEMS
SECTION PC 1301 GENERAL
FIGURE 1301.3 PICTOGRAPH—DO NOT DRINK
137 TABLE 1301.6 CONVEYANCE PIPE
139 SECTION PC 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS
140 TABLE 1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS
141 SECTION PC 1303 NONPOTABLE RAINWATER COLLECTION AND CONVEYANCE SYSTEMS
142 TABLE 1303.10.1 LOCATION OF RAINWATER STORAGE TANKS
143 SECTION PC 1304 RESERVED
144 CHAPTER 14 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
SECTION PC 1401 GENERAL
SECTION PC 1402 SYSTEM DESIGN AND SIZING
EQUATION 14-1
145 TABLE 1402.3 LOCATION OF SUBSURFACE IRRIGATION SYSTEM
SECTION PC 1403 INSTALLATION
TABLE 1403.1.1 DESIGN LOADING RATE
146 TABLE 1403.2 DISTRIBUTION PIPE
TABLE 1403.2.1 JOINTS AND FITTINGS
148 CHAPTER 15 REFERENCED STANDARDS
SECTION PC 1501 GENERAL
SECTION PC 1502 STANDARDS
AHRI
ANSI
API
149 ASCE/SEI
ASME
150 ASPE
ASSE
151 ASTM
153 AWS
AWWA
154 CISPI
CSA
155 IAPMO
ICC
ISEA
MSS
156 NFPA
NSF
PDI
UL
157 WATER SENSE
158 APPENDIX A RESERVED
160 APPENDIX B RESERVED
162 APPENDIX C STRUCTURAL SAFETY
SECTION PC C101 CUTTING, NOTCHING AND BORING
164 APPENDIX D RESERVED
166 APPENDIX E SIZING OF WATER PIPING SYSTEM
SECTION PC E101 GENERAL
SECTION PC E102 INFORMATION REQUIRED
SECTION PC E103 SELECTION OF PIPE SIZE
170 TABLE E.1
TABLE E.2
171 FIGURE E103.3(1) EXAMPLE-SIZING
172 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING)
173 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING)
174 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
175 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
176 FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa
177 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
178 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
179 TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND
180 TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
181 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
182 SECTION PC E201 RESERVED
SECTION PC E202 DETERMINATION OF PIPE VOLUMES
TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
184 INDEX RESERVED
186 ICC DIGITAL CODES PREMIUM
187 ICC ASSESSMENT CENTER
188 ICC LEARNING CENTER
189 ICC EVALUATION SERVICE
]]>
NY NYC BuildingCode 2022 1stptg ?u=/product/publishers/ny/ny-nyc-buildingcode-2022-1stptg/ Sun, 20 Oct 2024 06:12:40 +0000 New York City Building Code
Published By Publication Date Number of Pages
NY 2022 1095
]]>
This is a fully integrated custom code based on the 2015 International Building Code. Effective date: November 7, 2022.

PDF Catalog

PDF Pages PDF Title
1 2022 NEW YORK CITY BUILDING CODE
2 2022 NEW YORK CITY BUILDING CODE TITLE PAGE
3 COPYRIGHT
4 DEDICATION
6 NEW YORK CITY CONSTRUCTION CODES PREFACE
8 ACKNOWLEDGEMENTS
16 TITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES
17 TITLE 28 NEW YORK CITY CONSTRUCTION CODES
CHAPTER 7 THE NEW YORK CITY BUILDING CODE
ARTICLE 701 ENACTMENT AND UPDATE OF THE NEW YORK CITY BUILDING CODE
18 TABLE OF CONTENTS
28 CHAPTER 1 ADMINISTRATION
SECTION BC 101 GENERAL
SECTION BC 102 APPLICABILITY
29 SECTION BC 103 DEPARTMENT OF BUILDINGS
SECTION BC 104 DUTIES AND POWERS OF COMMISSIONER OF BUILDINGS
SECTION BC 105 APPROVALS
SECTION BC 106 PERMITS
30 SECTION BC 107 CONSTRUCTION DOCUMENTS
35 SECTION BC 108 TEMPORARY STRUCTURES AND USES
SECTION BC 109 FEES
SECTION BC 110 INSPECTIONS
36 SECTION BC 111 CERTIFICATE OF OCCUPANCY
SECTION BC 112 SERVICE UTILITIES
SECTION BC 113 RESERVED
SECTION BC 114 VIOLATIONS
SECTION BC 115 STOP WORK ORDER
SECTION BC 116 UNSAFE STRUCTURES AND EQUIPMENT
38 CHAPTER 2 DEFINITIONS
SECTION BC 201 GENERAL
39 SECTION BC 202 DEFINITIONS
43 EQUATION 2-1
EQUATION 2-2
EQUATION 2-3
84 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
SECTION BC 301 GENERAL
SECTION BC 302 CLASSIFICATION
SECTION BC 303 ASSEMBLY GROUP A
85 SECTION BC 304 BUSINESS GROUP B
SECTION BC 305 EDUCATIONAL GROUP E
86 SECTION BC 306 FACTORY GROUP F
87 SECTION BC 307 HIGH-HAZARD GROUP H
88 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
89 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, q
90 TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
92 SECTION BC 308 INSTITUTIONAL GROUP I
94 SECTION BC 309 MERCANTILE GROUP M
SECTION BC 310 RESIDENTIAL GROUP R
95 SECTION BC 311 STORAGE GROUP S
96 SECTION BC 312 UTILITY AND MISCELLANEOUS GROUP U
98 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION BC 401 SCOPE
SECTION BC 402 COVERED MALL AND OPEN MALL BUILDINGS
101 EQUATION 4-1
102 SECTION BC 403 HIGH-RISE BUILDINGS
103 TABLE 403.2.4 MINIMUM BOND STRENGTH
106 SECTION BC 404 ATRIUMS
107 SECTION BC 405 UNDERGROUND BUILDINGS AND SPACES
108 SECTION BC 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
110 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
114 SECTION BC 407 GROUP I-2
117 SECTION BC 408 GROUP I-3
119 SECTION BC 409 MOTION PICTURE PROJECTION ROOMS
120 SECTION BC 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
123 SECTION BC 411 SPECIAL AMUSEMENT BUILDINGS
124 SECTION BC 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.3.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
126 TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
127 TABLE 412.7 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
SECTION BC 413 COMBUSTIBLE STORAGE
SECTION BC 414 HAZARDOUS MATERIALS
128 TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
129 TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
130 TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
131 SECTION BC 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
133 TABLE 415.6.1 MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS
134 TABLE 415.6.2 DETACHED BUILDING REQUIRED
136 TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
141 SECTION BC 416 APPLICATION OF FLAMMABLE FINISHES
142 SECTION BC 417 DRYING ROOMS
SECTION BC 418 ORGANIC COATINGS
SECTION BC 419 RESERVED
SECTION BC 420 GROUPS I-1, R-1, R-2, R-3
143 SECTION BC 421 HYDROGEN FUEL GAS ROOMS
SECTION BC 422 AMBULATORY CARE FACILITIES
144 SECTION BC 423 STORM SHELTERS
SECTION BC 424 CHILDREN’S PLAY STRUCTURES
145 SECTION BC 425 HYPERBARIC FACILITIES
SECTION BC 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
SECTION BC 427 NONPRODUCTION CHEMICAL LABORATORIES
148 SECTION BC 428 USES AND OCCUPANCIES INVOLVING RADIOACTIVE MATERIALS AND RADIATION-PRODUCING EQUIPMENT
150 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS; SEPARATION OF OCCUPANCIES
SECTION BC 501 GENERAL
SECTION BC 502 DEFINITIONS
SECTION BC 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
151 SECTION BC 504 BUILDING HEIGHT AND NUMBER OF STORIES
152 TABLE 504.3a ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
153 TABLE 504.3a—continued ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
TABLE 504.4a, b ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
154 TABLE 504.4a, b—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
155 SECTION BC 505 MEZZANINES AND EQUIPMENT PLATFORMS
156 SECTION BC 506 BUILDING AREA MODIFICATIONS
TABLE 506.2a ALLOWABLE AREA FACTOR (At = NS, S1, S13D, S13R, or SM, as applicable) IN SQUARE FEET
157 TABLE 506.2a—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13D, S13R, or SM, as applicable) IN SQUARE FEET
158 TABLE 506.2a—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13D, S13R, or SM, as applicable) IN SQUARE FEET
EQUATION 5-1
159 EQUATION 5-2
EQUATION 5-3
EQUATION 5-4
160 EQUATION 5-5
SECTION BC 507 UNLIMITED AREA BUILDINGS
162 SECTION BC 508 MIXED USE AND OCCUPANCY
163 SECTION BC 509 INCIDENTAL USES
164 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION BC 510 SPECIAL PROVISIONS
165 TABLE 509c INCIDENTAL USES
168 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION BC 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION BC 602 CONSTRUCTION CLASSIFICATION
169 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
170 SECTION BC 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
172 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION BC 701 GENERAL
SECTION BC 702 DEFINITIONS
SECTION BC 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
173 SECTION BC 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
175 SECTION BC 705 EXTERIOR WALLS
176 TABLE 705.2 MINIMUM SETBACK DISTANCE OF PROJECTION
EQUATION 7-1
177 FIGURE 705.7 EQUIVALENT OPENING FACTOR
EQUATION 7-2
178 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTIONm
180 SECTION BC 706 FIRE WALLS
181 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
182 SECTION BC 707 FIRE BARRIERS
183 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
184 SECTION BC 708 FIRE PARTITIONS
185 SECTION BC 709 SMOKE BARRIERS
SECTION BC 710 SMOKE PARTITIONS
186 SECTION BC 711 HORIZONTAL ASSEMBLIES
187 SECTION BC 712 VERTICAL OPENINGS
188 SECTION BC 713 SHAFT ENCLOSURES
191 SECTION BC 714 PENETRATIONS
193 SECTION BC 715 FIRE-RESISTANT JOINT SYSTEMS
194 SECTION BC 716 OPENING PROTECTIVES
195 TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES
197 TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
199 TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
SECTION BC 717 DUCTS AND AIR TRANSFER OPENINGS
200 TABLE 717.3.2.1 FIRE DAMPER RATING
205 SECTION BC 718 CONCEALED SPACES
208 SECTION BC 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION BC 720 THERMAL- AND SOUND-INSULATING MATERIALS
209 SECTION BC 721 PRESCRIPTIVE FIRE RESISTANCE
210 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
211 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
212 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
213 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
214 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
215 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
216 TABLE 720.1(2)721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
217 TABLE 720.1(2)721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
218 TABLE 720.1(2)721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
219 TABLE 720.1(2)721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
220 TABLE 720.1(2)721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
221 TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
222 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
223 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
224 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
225 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
226 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
227 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
228 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
229 SECTION BC 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD BEARING OR NONLOAD-BEARING
EQUATION 7-3
230 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
EQUATION 7-4
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
231 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
232 TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
233 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
234 TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc(APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
235 TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
236 EQUATION 7-6
237 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
238 TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
TABLE 722.4.1(3) VALUES OF Rn0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pla
239 TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-8
EQUATION 7-9
EQUATION 7-10
EQUATION 7-11
240 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(2)—continued
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
241 FIGURE 722.5.1(3)—continued
FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARDa
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAY-APPLIED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
242 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
243 TABLE 722.5.1(2) PROPERTIES OF CONCRETE
TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
244 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
245 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
246 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
247 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
248 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
249 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa FIGURE 722.5.1(6)(c)‡
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa FIGURE 722.5.1(6)(c)‡
TABLE 722.5.1(8)—continued MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa FIGURE 722.5.1(6)(c)‡
TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa FIGURE 722.5.1(6)(a)‡
250 TABLE 722.5.1(9)—continued MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa FIGURE 722.5.1(6)(a)‡
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa FIGURE 722.5.1(6)(a)‡
TABLE 722.5.1(10)—continued MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa FIGURE 722.5.1(6)(a)‡
EQUATION 7-12
251 EQUATION 7-13
EQUATION 7-14
EQUATION 7-15
252 EQUATION 7-16
FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
253 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
254 TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
256 CHAPTER 8 INTERIOR FINISHES
SECTION BC 801 GENERAL
SECTION BC 802 DEFINITIONS
SECTION BC 803 WALL AND CEILING FINISHES
258 TABLE 803.11 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
259 SECTION BC 804 INTERIOR FLOOR FINISH
SECTION BC 805 COMBUSTIBLE FLOORING MATERIALS IN TYPES I AND II CONSTRUCTION
260 SECTION BC 806 DECORATIVE MATERIALS AND TRIM
SECTION BC 807 INSULATION
SECTION BC 808 ACOUSTICAL CEILING SYSTEMS
262 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION BC 901 GENERAL
264 SECTION BC 902 DEFINITIONS
265 SECTION BC 903 AUTOMATIC SPRINKLER SYSTEMS
267 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
270 TABLE 903.2.11.10 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
271 TABLE 903.2.11.10—continued ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
274 SECTION BC 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
276 SECTION BC 905 STANDPIPE SYSTEMS
281 SECTION BC 906 PORTABLE FIRE EXTINGUISHERS
SECTION BC 907 FIRE ALARM AND DETECTION SYSTEMS
291 TABLE 907.5.2.3.2 VISIBLE ALARMS
292 SECTION BC 908 EMERGENCY ALARM SYSTEMS
293 SECTION BC 909 SMOKE CONTROL SYSTEMS
295 EQUATION 9-1
302 SECTION BC 910 SMOKE AND HEAT REMOVAL
303 EQUATION 9-2
EQUATION 9-3
304 SECTION BC 911 FIRE COMMAND CENTER
SECTION BC 912 FIRE DEPARTMENT CONNECTIONS
305 SECTION BC 913 FIRE PUMPS
306 SECTION BC 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION BC 915 CARBON MONOXIDE DETECTION
308 SECTION BC 916 FIRE DEPARTMENT IN-BUILDING AUXILIARY RADIO COMMUNICATION SYSTEM (ARCS)
SECTION BC 917 POST-FIRE SMOKE PURGE SYSTEMS
310 SECTION BC 918 GAS DETECTION SYSTEMS
312 CHAPTER 10 MEANS OF EGRESS
SECTION BC 1001 ADMINISTRATION
SECTION BC 1002 DEFINITIONS
313 SECTION BC 1003 GENERAL MEANS OF EGRESS
314 SECTION BC 1004 OCCUPANT LOAD
315 TABLE 1004.1.3 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
316 TABLE 1004.1.3—continued MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
TABLE 1004.1.3—continued MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
317 SECTION BC 1005 MEANS OF EGRESS SIZING
318 SECTION BC 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
319 TABLE 1006.3.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
320 TABLE 1006.3.2 STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT
321 SECTION BC 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION BC 1008 MEANS OF EGRESS ILLUMINATION
323 SECTION BC 1009 ACCESSIBLE MEANS OF EGRESS
326 SECTION BC 1010 DOORS, GATES AND TURNSTILES
327 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.1.4.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
335 SECTION BC 1011 STAIRWAYS
340 SECTION BC 1012 RAMPS
341 SECTION BC 1013 EXIT SIGNS
342 SECTION BC 1014 HANDRAILS
343 SECTION BC 1015 GUARDS
345 SECTION BC 1016 EXIT ACCESS
346 SECTION BC 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
347 SECTION BC 1018 AISLES
SECTION BC 1019 EXIT ACCESS STAIRWAYS AND RAMPS
348 SECTION BC 1020 CORRIDORS
TABLE 1020.1.1 INTERIOR CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.1.2 PUBLIC CORRIDOR FIRE-RESISTANCE RATING
349 TABLE 1020.2 MINIMUM CORRIDOR WIDTH
SECTION BC 1021 EGRESS BALCONIES
350 SECTION BC 1022 EXITS
SECTION BC 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
352 SECTION BC 1024 EXIT PASSAGEWAYS
353 SECTION BC 1025 LUMINOUS EGRESS PATH MARKINGS
356 SECTION BC 1026 HORIZONTAL EXITS
357 SECTION BC 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
358 SECTION BC 1028 EXIT DISCHARGE
360 SECTION BC 1029 ASSEMBLY
362 TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
363 TABLE 1029.7 TRAVEL DISTANCE
365 TABLE 1029.12.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
369 SECTION BC 1030 EMERGENCY ESCAPE AND RESCUE
370 SECTION BC 1031 SIGNAGE
372 CHAPTER 11 ACCESSIBILITY
SECTION BC 1101 GENERAL
373 SECTION BC 1102 DEFINITIONS
SECTION BC 1103 SCOPING REQUIREMENTS
374 SECTION BC 1104 ACCESSIBLE ROUTE
376 SECTION BC 1105 ACCESSIBLE ENTRANCES
TABLE 1105.1.8 PUBLIC ENTRANCE WITH POWER-OPERATED DOORS
SECTION BC 1106 PARKING AND PASSENGER LOADING FACILITIES
377 TABLE 1106.7.3 VALET AND ATTENDED ACCESSIBLE PARKING SPACES
378 SECTION BC 1107 DWELLING UNITS AND SLEEPING UNITS
380 FIGURE 1107.2.2.7.3.1 SIDEWALL GRAB BAR LOCATION
381 FIGURE 1107.2.2.7.6 DISPENSER OUTLET LOCATION
385 TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
386 SECTION BC 1108 SPECIAL OCCUPANCIES
387 TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
388 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
389 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
SECTION BC 1109 OTHER FEATURES AND FACILITIES
395 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
396 SECTION BC 1110 RECREATIONAL FACILITIES
397 TABLE 1110.4.9.1 BOAT SLIPS
398 SECTION BC 1111 SIGNAGE
FIGURE 1111.1 DYNAMIC ACCESSIBILITY SYMBOL
400 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION BC 1201 GENERAL
SECTION BC 1202 DEFINITIONS
SECTION BC 1203 VENTILATION
401 TABLE 1203.3 INSULATION FOR CONDENSATION CONTROL
404 SECTION BC 1204 TEMPERATURE AND HUMIDITY CONTROL
405 TABLE 1204.1 MINIMUM SPACE TEMPERATURE REQUIREMENTS
SECTION BC 1205 LIGHTING
407 SECTION BC 1206 YARDS AND COURTS
408 SECTION BC 1207 SOUND TRANSMISSION
TABLE 1207.2.1 MAXIMUM SOUND PRESSURE LEVELS FOR MACHINE ROOMS ADJACENT TO DWELLING UNITS, MEASURED IN THE DWELLING UNIT
409 SECTION BC 1208 INTERIOR SPACE DIMENSIONS
410 SECTION BC 1209 ACCESS TO UNOCCUPIED SPACES
SECTION BC 1210 TOILET AND BATHROOM REQUIREMENTS
411 SECTION BC 1211 KITCHENS AND KITCHENETTES
SECTION BC 1212 RODENTPROOFING
SECTION BC 1213 REFUSE AND RECYCLABLE STORAGE
414 CHAPTER 13 ENERGY EFFICIENCY
SECTION BC 1301 GENERAL
416 CHAPTER 14 EXTERIOR WALLS
SECTION BC 1401 GENERAL
SECTION BC 1402 DEFINITIONS
SECTION BC 1403 PERFORMANCE REQUIREMENTS
418 SECTION BC 1404 MATERIALS
SECTION BC 1405 INSTALLATION OF WALL COVERINGS
419 TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
423 SECTION BC 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
424 TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
425 SECTION BC 1407 METAL COMPOSITE MATERIALS (MCM)
426 SECTION BC 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
427 SECTION BC 1409 HIGH-PRESSURE DECORATIVE EXTERIOR GRADE COMPACT LAMINATES (HPL)
SECTION BC 1410 PLASTIC COMPOSITE DECKING
428 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION BC 1501 GENERAL
SECTION BC 1502 DEFINITIONS
SECTION BC 1503 WEATHER PROTECTION
429 SECTION BC 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.1.1 CLASSIFICATION OF ASPHALT SHINGLES
430 SECTION BC 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
431 SECTION BC 1506 MATERIALS
SECTION BC 1507 REQUIREMENTS FOR ROOF COVERINGS
432 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
434 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
435 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
436 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
437 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
438 TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
439 TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
440 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
441 SECTION BC 1508 ROOF INSULATION
TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION BC 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION BC 1510 ROOFTOP STRUCTURES
443 SECTION BC 1511 REROOFING
444 SECTION BC 1512 SOLAR PHOTOVOLTAIC PANELS/MODULES AND REQUIRED SUSTAINABLE ROOFING ZONES
446 CHAPTER 16 STRUCTURAL DESIGN
SECTION BC 1601 GENERAL
SECTION BC 1602 DEFINITIONS AND NOTATIONS
447 SECTION BC 1603 CONSTRUCTION DOCUMENTS
448 SECTION BC 1604 GENERAL DESIGN REQUIREMENTS
449 TABLE 1604.3 DEFLECTION LIMITS
450 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
451 SECTION BC 1605 LOAD COMBINATIONS
452 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
453 EQUATION 16-21
EQUATION 16-22
EQUATION 16-23
EQUATION 16-24
EQUATION 16-25
EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
SECTION BC 1606 DEAD LOADS
SECTION BC 1607 LIVE LOADS
454 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, LO, AND MINIMUM CONCENTRATED LIVE LOADS
455 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, LO, AND MINIMUM CONCENTRATED LIVE LOADSg ‡
456 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, LO, AND MINIMUM CONCENTRATED LIVE LOADSg ‡
457 TABLE 1607.5 EQUIVALENT UNIFORM PARTITION LOADS
459 EQUATION 16-30
TABLE 1607.11.1 LIVE LOAD ELEMENT FACTOR, KLL
460 EQUATION 16-31
EQUATION 16-32
EQUATION 16-33
EQUATION 16-34
EQUATION 16-35
EQUATION 16-36
EQUATION 16-37
EQUATION 16-38
EQUATION 16-39
462 SECTION BC 1608 SNOW LOADS
SECTION BC 1609 WIND LOADS
463 TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
464 TABLE 1609.3 BASIC DESIGN WIND SPEED
EQUATION 16-40
465 TABLE 1609.3.2 SERVICEABILITY DESIGN WIND SPEED
466 FIGURE 1609.4.3(1) NEW YORK CITY WIND EXPOSURE: MANHATTAN SHORELINE
467 FIGURE 1609.4.3(2) NEW YORK CITY WIND EXPOSURE: BRONX SHORELINE
468 FIGURE 1609.4.3(3) NEW YORK CITY WIND EXPOSURE: BROOKLYN SHORELINE
469 FIGURE 1609.4.3(4) NEW YORK CITY WIND EXPOSURE: QUEENS SHORELINE
470 FIGURE 1609.4.3(5) NEW YORK CITY WIND EXPOSURE: STATEN ISLAND SHORELINE
471 EQUATION 16-45
472 TABLE 1609.7 NET PRESSURE COEFFICIENT, (GCPN) FOR ATTACHED CANOPIES ON BUILDINGS WITH H>60 FT
FIGURE 1609.7 SCHEMATIC OF ATTACHED CANOPY ON BUILDINGS WITH h > 60 FT
EQUATION 16-42
SECTION BC 1610 SOIL LATERAL LOADS
SECTION BC 1611 RAIN LOADS
EQUATION 16-43
473 TABLE 1610.1 LATERAL SOIL LOAD
SECTION BC 1612 FLOOD LOADS
SECTION BC 1613 EARTHQUAKE LOADS
474 EQUATION 16-44
EQUATION 16-45
TABLE 1613.3.3(1) VALUES OF SITE COEFFICIENT Fa AS A FUNCTION OF SITE CLASS AND MAPPED SPECTRAL RESPONSE ACCELERATION AT SHORT PERIODS
475 TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT Fv AS A FUNCTION OF SITE CLASS AND MAPPED SPECTRAL RESPONSE ACCELERATION AT 1-SECOND PERIOD
EQUATION 16-46
EQUATION 16-47
EQUATION 16-48
EQUATION 16-49
EQUATION 16-50
476 TABLE 1613.3.4.1 SITE CLASSIFICATION
TABLE 1613.3.5 SEISMIC DESIGN CATEGORY
477 TABLE 1613.5 DESIGN COEFFICIENT AND FACTORS FOR BASIC SEISMIC C-FORCE-RESISTING SYSTEMS
478 TABLE 1613.5—continued DESIGN COEFFICIENT AND FACTORS FOR BASIC SEISMIC C-FORCE-RESISTING SYSTEMS
479 TABLE 1613.5—continued DESIGN COEFFICIENT AND FACTORS FOR BASIC SEISMIC C-FORCE-RESISTING SYSTEMS
480 TABLE 1613.5—continued DESIGN COEFFICIENT AND FACTORS FOR BASIC SEISMIC C-FORCE-RESISTING SYSTEMS
481 SECTION BC 1614 ATMOSPHERIC ICE LOADS
SECTION BC 1615 STRUCTURAL INTEGRITY DEFINITIONS
SECTION BC 1616 STRUCTURAL INTEGRITY—PRESCRIPTIVE REQUIREMENTS
482 SECTION BC 1617 STRUCTURAL INTEGRITY—KEY ELEMENT ANALYSIS
TABLE 1617.8.3 RESPONSE RATIO AND ROTATION LIMITS
483 SECTION BC 1618 STRUCTURAL PEER REVIEW
484 SECTION 1619 TEMPORARY STRUCTURES AND TEMPORARY CONSTRUCTION INSTALLATIONS
488 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION BC 1701 GENERAL
SECTION BC 1702 DEFINITIONS
SECTION BC 1703 APPROVALS
SECTION BC 1704 RESPONSIBILITIES FOR SPECIAL INSPECTIONS AND TESTS
491 SECTION BC 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
492 TABLE 1705.2 REQUIRED SPECIAL INSPECTION OF STEEL CONSTRUCTION
493 TABLE 1705.2—continued REQUIRED SPECIAL INSPECTION OF STEEL CONSTRUCTION‡
494 TABLE 1705.2.6 REQUIRED SPECIAL INSPECTION OF COLD-FORMED STEEL CONSTRUCTION
495 TABLE 1705.2.6—continued REQUIRED SPECIAL INSPECTION OF COLD-FORMED STEEL CONSTRUCTION
TABLE 1705.2.7 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
496 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
497 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
498 TABLE 1705.4.1 LEVEL B REQUIRED SPECIAL INSPECTIONS AND TESTS OF MASONRY CONSTRUCTION
499 TABLE 1705.4.1—continued LEVEL B REQUIRED SPECIAL INSPECTIONS AND TESTS OF MASONRY CONSTRUCTION
TABLE 1705.4.3 LEVEL C REQUIRED SPECIAL INSPECTIONS AND TESTS OF MASONRY CONSTRUCTION
500 TABLE 1705.4.3—continued LEVEL C REQUIRED SPECIAL INSPECTIONS AND TESTS OF MASONRY CONSTRUCTION
502 TABLE 1705.5.6 REQUIRED SPECIAL INSPECTIONS OF TYPE IV CONSTRUCTION UTILIZING CROSS-LAMINATED TIMBER OR STRUCTURAL COMPOSITE LUMBER
TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS OF SUBSURFACE CONDITIONS
503 TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DEEP FOUNDATION ELEMENTS
504 TABLE 1705.7.1 REQUIRED SPECIAL INSPECTIONS OF DRIVEN AND VIBRATED DEEP FOUNDATION ELEMENTS
TABLE 1705.7.2 REQUIRED SPECIAL INSPECTIONS OF DRILLED DEEP FOUNDATION ELEMENTS
TABLE 1705.7.3 REQUIRED SPECIAL INSPECTIONS OF DRIVEN OR DRILLED CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
TABLE 1705.8.1 REQUIRED SPECIAL INSPECTIONS OF PRESTRESSED SOIL AND ROCK ANCHORS
505 TABLE 1705.8.1—continued REQUIRED SPECIAL INSPECTIONS OF PRESTRESSED SOIL AND ROCK ANCHORS
516 TABLE 1705.37 REQUIRED VERIFICATION AND INSPECTION OF POST-INSTALLED ANCHORS
SECTION BC 1706 DESIGN STRENGTHS OF MATERIALS
517 SECTION BC 1707 ALTERNATIVE TEST PROCEDURE
SECTION BC 1708 IN-SITU LOAD TESTS
SECTION BC 1709 PRECONSTRUCTION LOAD TESTS
518 SECTION BC 1710 TEST SAFE LOAD
SECTION BC 1711 MATERIAL AND TEST STANDARDS
520 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION BC 1801 GENERAL
SECTION BC 1802 GENERAL
SECTION BC 1803 GEOTECHNICAL INVESTIGATIONS AND MATERIAL CLASSIFICATIONS
523 TABLE 1803.3 UNIFIED SOIL CLASSIFICATION
525 SECTION BC 1804 EXCAVATION, GRADING AND FILL
526 SECTION BC 1805 DAMPPROOFING AND WATERPROOFING
527 SECTION BC 1806 ALLOWABLE LOAD-BEARING VALUES OF SOILS AND ROCK
528 TABLE 1806.1 ALLOWABLE BEARING PRESSURES
529 SECTION BC 1807 RETAINING WALLS AND OTHER RETAINING STRUCTURES
SECTION BC 1808 RESERVED
530 SECTION BC 1809 SHALLOW FOUNDATIONS
532 SECTION BC 1810 DEEP FOUNDATIONS
534 TABLE 1810.2.13 MINIMUM CONCRETE COVER FOR CAST IN PLACE AND PRECAST CONCRETE PILESa
536 TABLE 1810.4.1.3 BASIC MAXIMUM ALLOWABLE PILE LOADS
539 TABLE 1810.8 ALLOWABLE AXIAL STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTSa
541 SECTION BC 1811 DRIVEN DEEP FOUNDATIONS
542 TABLE 1811.3(a) MINIMUM DRIVING RESISTANCE AND MINIMUM HAMMER ENERGY FOR STEEL H-PILES, PIPE PILES, PRECAST AND CAST-IN-PLACE CONCRETE PILES AND COMPOSITE PILES
TABLE 1811.3(b) MINIMUM DRIVING RESISTANCE AND HAMMER ENERGY FOR TIMBER PILES
544 EQUATION 18-1
EQUATION 18-2
EQUATION 18-3
545 EQUATION 18-4
EQUATION 18-5
546 SECTION BC 1812 CAST-IN-PLACE CONCRETE PILES
547 EQUATION 18-6
551 SECTION BC 1813 COMPOSITE PILES
SECTION BC 1814 HELICAL PILES
553 SECTION BC 1815 PERMANENT PRESTRESSED ROCK AND SOIL ANCHORS
554 SECTION BC 1816 LIQUEFACTION ANALYSIS
TABLE 1816.2.1 VALUES OF MAXIMUM CONSIDERED EARTHQUAKE MEAN (MCEG) PEAK GROUND ACCELERATIONS ADJUSTED FOR SITE CLASS EFFECTS, PGAM
555 FIGURE 1816.1 LIQUEFACTION ASSESSMENT DIAGRAM
SECTION BC 1817 UNDERPINNING AND ALTERNATE METHODS OF SUPPORT OF BUILDINGS AND ADJACENT PROPERTY
560 SECTION BC 1818 GEOTECHNICAL PEER REVIEW
562 CHAPTER 19 CONCRETE
SECTION BC 1901 GENERAL
SECTION BC 1902 DEFINITIONS
SECTION BC 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
563 SECTION BC 1904 DURABILITY REQUIREMENTS
TABLE 1904.3 MINIMUM SPECIFIED COMPRESSIVE STRENGTH
564 TABLE 1904.4.2 REQUIREMENTS FOR CONCRETE EXPOSED TO DEICING CHEMICALS
SECTION BC 1905 CONCRETE QUALITY, MIXING AND PLACING
570 SECTION BC 1906 FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS
SECTION BC 1907 DETAILS OF REINFORCEMENT
572 SECTION BC 1908 MODIFICATIONS TO ACI 318
575 SECTION BC 1909 STRUCTURAL PLAIN CONCRETE
SECTION BC 1910 MINIMUM SLAB PROVISIONS
SECTION BC 1911 SHOTCRETE
576 SECTION BC 1912 STRUCTURAL INTEGRITY REQUIREMENTS
577 SECTION BC 1913 ASPHALT PAVING
580 CHAPTER 20 ALUMINUM
SECTION BC 2001 GENERAL
SECTION BC 2002 MATERIALS
SECTION BC 2003 ADDITIONAL REQUIREMENTS
582 CHAPTER 21 MASONRY
SECTION BC 2101 GENERAL
SECTION BC 2102 DEFINITIONS AND NOTATIONS
583 SECTION BC 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
584 SECTION BC 2104 CONSTRUCTION
585 SECTION BC 2105 QUALITY ASSURANCE
SECTION BC 2106 SEISMIC DESIGN
SECTION BC 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
586 SECTION BC 2108 STRENGTH DESIGN OF MASONRY
SECTION BC 2109 EMPIRICAL DESIGN OF MASONRY
TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS
587 TABLE 2109.4.3 MINIMUM THICKNESS OF MASONRY PARTITIONS
SECTION BC 2110 GLASS UNIT MASONRY
SECTION BC 2111 MASONRY FIREPLACES
TABLE 2111.1 REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYSa
588 FIGURE 2111.1 FIREPLACE AND CHIMNEY DETAILS
590 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
591 SECTION BC 2112 MASONRY HEATERS
SECTION BC 2113 MASONRY CHIMNEYS
594 EQUATION 21-2
TABLE 2113.9 “F” FACTOR FOR DETERMINING CHIMNEY DISTANCES
597 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
598 TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZESa
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION TO CHIMNEY CLEARANCE PROVISION
599 SECTION BC 2114 STRUCTURAL INTEGRITY REQUIREMENTS
600 CHAPTER 22 STEEL
SECTION BC 2201 GENERAL
SECTION BC 2202 DEFINITIONS
SECTION BC 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION BC 2204 CONNECTIONS
SECTION BC 2205 STRUCTURAL STEEL
601 SECTION BC 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION BC 2207 STEEL JOISTS
602 SECTION BC 2208 STEEL CABLE STRUCTURES
SECTION BC 2209 STEEL STORAGE RACKS
603 SECTION BC 2210 COLD-FORMED STEEL
SECTION BC 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
604 SECTION BC 2212 MINIMUM THICKNESS OF METAL
SECTION BC 2213 STRUCTURAL INTEGRITY REQUIREMENTS
606 CHAPTER 23 WOOD
SECTION BC 2301 GENERAL
SECTION BC 2302 DEFINITIONS
SECTION BC 2303 MINIMUM STANDARDS AND QUALITY
611 SECTION BC 2304 GENERAL CONSTRUCTION REQUIREMENTS
612 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
613 TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)
614 TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS
615 TABLE 2304.9.3.2.1 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKNESS
616 TABLE 2304.10.1 FASTENING SCHEDULE
617 TABLE 2304.10.1—continuedF ASTENING SCHEDULE
618 TABLE 2304.10.1—continued FASTENING SCHEDULE
619 TABLE 2304.10.1—continued FASTENING SCHEDULE
621 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
623 SECTION BC 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
624 EQUATION 23-1
TABLE 2305.2(1)en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP
EQUATION 23-2
SECTION BC 2306 ALLOWABLE STRESS DESIGN
625 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
626 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
627 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
628 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
629 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
630 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
SECTION BC 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION BC 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
631 TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
632 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b, c, d FOR EXTERIOR BEARING WALLS
633 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b, c, d FOR EXTERIOR BEARING WALLS
634 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS
635 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
636 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
637 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
638 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
639 FIGURE 2308.4.2.4 JOIST BORING AND NOTCHING LIMITS
640 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
641 FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
643 FIGURE 2308.5.8 WALL BORING AND NOTCHING LIMITS
644 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
645 TABLE 2308.6.1a WALL BRACING REQUIREMENTS
646 TABLE 2308.6.3(1) BRACING METHODS
647 TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
648 TABLE 2308.6.3(5) HARDBOARD SIDING
649 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
650 FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
651 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
652 FIGURE 2308.6.8.2(1) ROOF IN SDC D NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D BEYOND BRACED WALL LINE
653 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
655 TABLE 2308.7.1(1) CEILING- JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
656 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
657 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
658 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
659 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
660 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
661 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, Ceiling Attached to Rafters, L/Δ = 240)
662 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, Ceiling Attached to Rafters, L/Δ = 240)
663 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
664 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
665 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
666 TABLE 2308.7.2(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
667 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, Ceiling Attached to Rafters, L/Δ = 240)
668 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, Ceiling Attached to Rafters, L/Δ = 240)
669 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, Ceiling Attached to Rafters, L/Δ = 240)
670 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, Ceiling Attached to Rafters, L/Δ = 240)
671 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONS
672 TABLE 2308.7.3.1—continued RAFTER TIE CONNECTIONSg
TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS
674 TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
675 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
SECTION BC 2309 WOOD FRAME CONSTRUCTION MANUAL
676 CHAPTER 24 GLASS AND GLAZING
SECTION BC 2401 GENERAL
SECTION BC 2402 DEFINITIONS
SECTION BC 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION BC 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
677 EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
678 EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
SECTION BC 2405 SLOPED GLAZING AND SKYLIGHTS
679 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION BC 2406 SAFETY GLAZING
680 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
681 SECTION BC 2407 GLASS IN HANDRAILS AND GUARDS
682 SECTION BC 2408 GLAZING IN ATHLETIC FACILITIES
SECTION BC 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
SECTION BC 2410 MARKING OF TRANSPARENT DOORS AND FIXED ADJACENT TRANSPARENT SIDELITES
684 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION BC 2501 GENERAL
SECTION BC 2502 DEFINITIONS
SECTION BC 2503 RESERVED
SECTION BC 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION BC 2505 SHEAR WALL CONSTRUCTION
SECTION BC 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
685 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION BC 2507 LATHING AND PLASTERING
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION BC 2508 GYPSUM CONSTRUCTION
686 TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
687 SECTION BC 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION BC 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
688 SECTION BC 2511 INTERIOR PLASTER
TABLE 2511.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION BC 2512 EXTERIOR PLASTER
689 TABLE 2512.6 CEMENT PLASTERS
SECTION BC 2513 EXPOSED AGGREGATE PLASTER
SECTION BC 2514 REINFORCED GYPSUM CONCRETE
690 CHAPTER 26 PLASTIC
SECTION BC 2601 GENERAL
SECTION BC 2602 DEFINITIONS
SECTION BC 2603 FOAM PLASTIC INSULATION
694 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
695 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION BC 2604 INTERIOR FINISH AND TRIM
696 TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION BC 2605 PLASTIC VENEER
SECTION BC 2606 LIGHT-TRANSMITTING PLASTICS
698 SECTION BC 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
SECTION BC 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
699 SECTION BC 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION BC 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
700 SECTION BC 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION BC 2612 PLASTIC COMPOSITES
701 SECTION BC 2613 FIBER-REINFORCED POLYMER
SECTION BC 2614 REFLECTIVE PLASTIC CORE INSULATION
704 CHAPTER 27 ELECTRICAL
SECTION BC 2701 GENERAL
SECTION BC 2702 EMERGENCY AND STANDBY POWER SYSTEMS
708 CHAPTER 28 MECHANICAL SYSTEMS
SECTION BC 2801 GENERAL
710 CHAPTER 29 PLUMBING SYSTEMS
SECTION BC 2901 GENERAL
712 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION BC 3001 GENERAL
713 SECTION BC 3002 HOISTWAY ENCLOSURES
714 SECTION BC 3003 EMERGENCY OPERATIONS
715 SECTION BC 3004 CONVEYING SYSTEMS
716 SECTION BC 3005 MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES AND CONTROL ROOMS
SECTION BC 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
717 SECTION BC 3007 FIRE SERVICE ACCESS ELEVATOR
718 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
719 SECTION BC 3008 OCCUPANT EVACUATION ELEVATORS
721 SECTION BC 3009 SERVICE EQUIPMENT CERTIFICATES
SECTION BC 3010 ELEVATOR, AMUSEMENT AND OTHER DEVICE OPERATORS
SECTION BC 3011 ELEVATOR BEING SERVICED, REPAIRED, INSPECTED OR TESTED
722 SECTION BC 3012 ACCIDENTS
SECTION BC 3013 EXISTING INSTALLATIONS
SECTION BC 3014 INSPECTION AND TESTING
724 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION BC 3101 GENERAL
SECTION BC 3102 MEMBRANE STRUCTURES
726 SECTION BC 3103 TEMPORARY STRUCTURES
SECTION BC 3104 PEDESTRIAN WALKWAYS AND TUNNELS
728 SECTION BC 3105 AWNINGS, CANOPIES AND SUN CONTROL DEVICES
SECTION BC 3106 MARQUEES
SECTION BC 3107 SIGNS
SECTION BC 3108 RADIO, TELEVISION, AND TELECOMMUNICATIONS TOWERS AND ANTENNAS
729 SECTION BC 3109 SWIMMING POOLS, SWIMMING POOL ENCLOSURES, AND SAFETY DEVICES
732 SECTION BC 3110 AUTOMATIC VEHICULAR GATES
SECTION BC 3111 SIDEWALK CAFÉS
733 SECTION BC 3112 FENCES
SECTION BC 3113 PHOTOVOLTAIC PANELS AND MODULES
SECTION BC 3114 LARGE WIND TURBINES
734 SECTION BC 3115 SMALL WIND TURBINES
736 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION BC 3201 GENERAL
SECTION BC 3202 ENCROACHMENTS
742 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION OR DEMOLITION
SECTION BC 3301 GENERAL
744 FIGURE 3301.9.1.4(1) FENCE PROJECT INFORMATION PANEL TEXT DETAIL
745 FIGURE 3301.9.1.4(2) FENCE PROJECT INFORMATION PANEL LAYOUT
FIGURE 3301.9.1.4(3) FENCE PROJECT INFORMATION PANEL LAYOUT FOR SMALL LOTS
746 FIGURE 3301.9.2.1 SIDEWALK SHED PARAPET INFORMATION PANEL LAYOUT
747 FIGURE 3301.9.2.2 PANEL POSTING ELEVATION DIAGRAM
752 SECTION BC 3302 DEFINITIONS
754 SECTION BC 3303 SAFEGUARDS AND MAINTENANCE OF SITE
766 SECTION BC 3304 SOIL AND FOUNDATION WORK
768 TABLE 3304.4.1 MINIMUM SIZES OF TIMBER BRACING AND TIMBER SHEET PILING FOR TRENCHES NOT EXCEEDING 10 FEET (3048 MM) IN DEPTH AND 15 FEET (4572 MM) IN WIDTH
769 TABLE 3304.4.2 MAXIMUM ALLOWABLE SLOPES AND STEPS
771 SECTION BC 3305 MATERIAL PLACEMENT AND INSTALLATION
773 TABLE 3305.3.2.3 MINIMUM LATERAL PRESSURES TO BE ASSUMED FOR FRESH CONCRETE WEIGHING 150 POUNDS PER CUBIC FOOT
779 SECTION BC 3306 DEMOLITION
786 SECTION BC 3307 PROTECTION OF PEDESTRIANS
795 SECTION BC 3308 UNENCLOSED PERIMETER PROTECTION
801 SECTION BC 3309 PROTECTION OF ADJOINING PROPERTY
805 SECTION BC 3310 REQUIREMENTS FOR THE CONSTRUCTION OR DEMOLITION OF MAJOR BUILDINGS
809 SECTION BC 3311 EXPLOSIVE POWERED AND PROJECTILE TOOLS
810 SECTION BC 3312 EXPLOSIVES AND BLASTING
SECTION BC 3313 FLAMMABLE AND COMBUSTIBLE MIXTURES, COMPRESSED GASES, AND OTHER HAZARDOUS MATERIALS
SECTION BC 3314 SCAFFOLDS
817 TABLE 3314.4.4.12 MINIMUM DISTANCES FROM POWER LINES
819 TABLE 3314.5.2 MAXIMUM PERMISSIBLE SPANS FOR 2-INCH PLANK USED ON SCAFFOLDS
825 TABLE 3314.12.1(1) MINIMUM SIZE AND MAXIMUM SPACING OF MEMBERS OF SINGLE WOOD POLE LIGHT DUTY SCAFFOLDS
826 TABLE 3314.12.1(2) MINIMUM SIZE AND MAXIMUM SPACING OF MEMBERS OF SINGLE WOOD POLE MEDIUM DUTY SCAFFOLDS
827 TABLE 3314.12.1(3) MINIMUM SIZE AND MAXIMUM SPACING OF MEMBERS OF SINGLE WOOD POLE HEAVY DUTY SCAFFOLDS
828 TABLE 3314.12.1(4) MINIMUM SIZE AND MAXIMUM SPACING OF MEMBERS OF INDEPENDENT WOOD POLE LIGHT DUTY SCAFFOLDS
829 TABLE 3314.12.1(5) MINIMUM SIZE AND MAXIMUM SPACING OF MEMBERS OF INDEPENDENT WOOD POLE MEDIUM DUTY SCAFFOLDS
830 TABLE 3314.12.1(6) MINIMUM SIZE AND MAXIMUM SPACING OF MEMBERS OF INDEPENDENT WOOD POLE HEAVY DUTY SCAFFOLDS
TABLE 3314.12.3 SIZE AND NUMBER OF NAILS REQUIRED FOR SCAFFOLD CONSTRUCTION
833 SECTION BC 3315 STRUCTURAL RAMPS, RUNWAYS, AND PLATFORMS
834 SECTION BC 3316 HOISTING EQUIPMENT AND MATERIAL HANDLING EQUIPMENT
839 SECTION BC 3317 MATERIAL HOISTS AND BUCKET HOISTS
SECTION BC 3318 PERSONNEL HOISTS
SECTION BC 3319 CRANES AND DERRICKS
844 TABLE 3319.13 WIND MEASUREMENT REQUIREMENTS FOR CRANES AND DERRICKS
845 SECTION BC 3320 ADDITIONAL REQUIREMENTS FOR CERTAIN MATERIAL HANDLING EQUIPMENT
846 SECTION BC 3321 CONSTRUCTION SITE SAFETY TRAINING
848 CHAPTER 34 RESERVED
850 CHAPTER 35 REFERENCED STANDARDS
SECTION BC 3501 GENERAL
SECTION BC 3502 STANDARDS
AA
AAMA
AASHTO
851 ACI
AISC
AISI
852 AMCA
ANSI
853 APA
API
APSP
854 AREMA
ASABE
ASCE/SEI
855 ASME
ASTM
862 AWC
AWCI
863 AWPA
AWS
AWWA
BHMA
CEN
864 CGSB
CPA
CPSC
CSA
865 CSSB
DASMA
DOC
DOJ
866 DOL
DOT
DOTn
FEMA
867 FM
GA
HPVA
HUD
868 ICC
IEC
ISO
869 ITU
NAAMM
NCMA
NFPA
871 PCI
PTI
RCSC
RMI
872 SBCA
SDI
SJI
SPRI
873 TIA
TMS
TPI
UL
875 ULC
USC
WCLIB
WDMA
876 APPENDIX A RESERVED
878 APPENDIX B RESERVED
880 APPENDIX C RESERVED
882 APPENDIX D FIRE DISTRICTS
SECTION BC D101 GENERAL
SECTION BC D102 BUILDING RESTRICTIONS
SECTION BC D103 CHANGES TO BUILDINGS
SECTION BC D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION BC D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
883 SECTION BC D106 FIRE DISTRICT MAPS FOR THE BOROUGHS OF STATEN ISLAND (RICHMOND COUNTY) AND QUEENS
884 FIGURE D106.1(1) FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
885 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
886 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
887 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
888 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
889 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
890 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
891 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
892 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
893 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
894 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
895 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
896 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
897 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
898 FIGURE D106.1(1)—continued FIRE DISTRICT MAPS BOROUGH OF STATEN ISLAND (RICHMOND COUNTY)
899 FIGURE D106.1(2) FIRE DISTRICT MAPS BOROUGH OF QUEENS
900 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
901 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
902 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
903 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
904 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
905 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
906 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
907 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
908 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
909 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
910 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
911 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
912 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
913 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
914 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
915 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
916 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
917 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
918 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
919 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
920 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
921 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
922 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
923 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
924 FIGURE D106.1(2)—continued FIRE DISTRICT MAPS BOROUGH OF QUEENS
926 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION BC E101 GENERAL
SECTION BC E102 DEFINITIONS
SECTION BC E103 ACCESSIBLE ROUTE
SECTION BC E104 SPECIAL OCCUPANCIES
TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
927 SECTION BC E105 OTHER FEATURES AND FACILITIES
SECTION BC E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
928 SECTION BC E107 SIGNAGE
SECTION BC E108 RESERVED
SECTION BC E109 TRANSPORTATION FACILITIES AND STATIONS
929 SECTION BC E110 RESERVED
SECTION BC E111 REFERENCED STANDARDS
932 APPENDIX F RODENTPROOFING
SECTION BC F101 GENERAL
SECTION BC F102 PROTECTION
934 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION BC G101 PURPOSE AND OBJECTIVES
SECTION BC G102 APPLICABILITY
937 SECTION BC G103 ADMINISTRATION
938 SECTION BC G104 PERMITS
940 SECTION BC G105 VARIANCES
941 SECTION BC G106 CERTIFICATES OF OCCUPANCY
SECTION BC G107 PERIODIC, PROGRESS AND SPECIAL INSPECTION REQUIREMENTS
942 SECTION BC G201 DEFINITIONS
944 SECTION BC G301 CONSTRUCTION STANDARDS
SECTION BC G302 SUBDIVISIONS
SECTION BC G303 SITE IMPROVEMENT
945 SECTION BC G304 POST-FIRM CONSTRUCTION, HORIZONTAL ENLARGEMENTS AND SUBSTANTIAL IMPROVEMENTS
950 SECTION BC G305 MANUFACTURED HOMES
SECTION BC G306 RECREATIONAL VEHICLES
SECTION BC G307 TANKS
951 SECTION BC G308 OTHER BUILDING WORK
952 SECTION BC G309 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION BC G310 UTILITY AND MISCELLANEOUS GROUP U
SECTION BC G311 HAZARDOUS SUBSTANCES
953 SECTION BC G312 RETROACTIVE REQUIREMENTS
SECTION BC G401 REFERENCED STANDARDS
954 SECTION BC G402 STANDARDS
SECTION BC G501 MODIFICATIONS TO REFERENCED STANDARDS
955 TABLE 1-1 FLOOD DESIGN CLASS OF BUILDINGS AND STRUCTURES
956 TABLE 2-1 MINIMUM ELEVATION OF THE TOP OF LOWEST FLOOR FLOOD HAZARD AREAS OTHER THAN COASTAL HIGH-HAZARD AREASa, COASTAL A-ZONESa
TABLE 4-1 MINIMUM ELEVATION OF BOTTOM OF LOWEST SUPPORTING HORIZONTAL STRUCTURAL MEMBER OF LOWEST FLOOR COASTAL HIGH-HAZARD AREAS AND COASTAL A-ZONES
TABLE 5-1 MINIMUM ELEVATION BELOW WHICH FLOOD-DAMAGE-RESISTANT MATERIALS SHALL BE USED
TABLE 6-1 MINIMUM ELEVATION OF FLOOD PROOFING FLOOD HAZARD AREAS OTHER THAN COASTAL HIGH-HAZARD AREASa
960 TABLE 7-1 MINIMUM ELEVATION OF ATTENDANT UTILITIES AND EQUIPMENT
961 SECTION BC G601 RESERVED
SECTION BC G701 RESERVED
SECTION BC G801 RESERVED
SECTION BC G901 RESERVED
SECTION BC G1001 RESERVED
SECTION BC G1101 RESERVED
962 APPENDIX H OUTDOOR SIGNS
SECTION BC H101 GENERAL
SECTION BC H102 DEFINITIONS
SECTION BC H103 LOCATION
SECTION BC H104 IDENTIFICATION
SECTION BC H105 DESIGN AND CONSTRUCTION
963 SECTION BC H106 ELECTRICAL
SECTION BC H107 MATERIAL LIMITATIONS
964 SECTION BC H108 ANIMATED DEVICES
SECTION BC H109 GROUND SIGNS
SECTION BC H110 ROOF SIGNS
SECTION BC H111 WALL SIGNS
SECTION BC H112 PROJECTING SIGNS
965 TABLE H112.6 THICKNESS OF PROJECTING SIGNS
SECTION BC H113 MARQUEE SIGNS
SECTION BC H114 FLEXIBLE FABRIC SIGNS
967 SECTION BC H115 PORTABLE SIGNS
SECTION BC H116 TEMPORARY SIGNS
SECTION BC H117 REFERENCED STANDARDS
968 APPENDIX I RESERVED
970 APPENDIX J RESERVED
972 APPENDIX K MODIFIED INDUSTRY STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS
CHAPTER K1 MODIFICATIONS TO ASME A17.1-2013, SAFETY CODE FOR ELEVATORS AND ESCALATORS
PART 1 GENERAL
SECTION 1.1 SCOPE
SECTION 1.2 PURPOSE AND EXCEPTIONS
SECTION 1.3 DEFINITIONS
973 PART 2 ELECTRIC ELEVATORS
SECTION 2.1 CONSTRUCTION OF HOISTWAYS AND HOISTWAY ENCLOSURES
SECTION 2.2 PITS
SECTION 2.5 HORIZONTAL CAR AND COUNTER WEIGHT CLEARANCES
974 SECTION 2.7 MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS
FIGURE Q-2
975 SECTION 2.8 EQUIPMENT IN HOISTWAYS, MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS
SECTION 2.11 PROTECTION OF HOISTWAY OPENINGS
976 SECTION 2.12 HOISTWAY DOOR LOCKING DEVICES AND ELECTRIC CONTACTS, AND HOISTWAY ACCESS SWITCHES
977 SECTION 2.13 POWER OPERATION OF HOISTWAY DOORS AND CAR DOORS
SECTION 2.14 CAR ENCLOSURES, CAR DOORS AND GATES, AND CAR ILLUMINATION
979 SECTION 2.15 CAR FRAMES AND PLATFORMS
SECTION 2.16 CAPACITY AND LOADING
980 SECTION 2.18 SPEED GOVERNORS
SECTION 2.20 SUSPENSION MEANS AND THEIR CONNECTIONS
SECTION 2.21 COUNTERWEIGHTS
SECTION 2.22 BUFFERS AND BUMPERS
981 SECTION 2.24 DRIVING MACHINES AND SHEAVES
SECTION 2.25 TERMINAL STOPPING DEVICES
SECTION 2.26 OPERATING DEVICES AND CONTROL EQUIPMENT
982 SECTION 2.27 EMERGENCY OPERATION AND SIGNALING DEVICES
986 FIGURE 2.27.3.1.6(h) VISUAL SIGNAL
989 FIGURE 2.27.3.3.7 PANEL LAYOUT
995 SECTION 2.28 LAYOUT DRAWINGS
SECTION 2.29 IDENTIFICATION
996 PART 3 HYDRAULIC ELEVATORS
SECTION 3.7 MACHINERY SPACES, MACHINE ROOMS, CONTROL SPACES, AND CONTROL ROOMS
SECTION 3.16 CAPACITY AND LOADING
SECTION 3.26 OPERATING DEVICES AND CONTROL EQUIPMENT
PART 4 ELEVATORS WITH OTHER TYPES OF DRIVING MACHINES
SECTION 4.3 HAND ELEVATORS
PART 5 SPECIAL APPLICATION ELEVATORS
SECTION 5.2 LIMITED-USE/LIMITED-APPLICATION ELEVATORS
997 SECTION 5.3 PRIVATE RESIDENCE ELEVATORS
999 SECTION 5.4 PRIVATE RESIDENCE INCLINED ELEVATORS
SECTION 5.5 POWER SIDEWALK ELEVATORS
SECTION 5.12 OUTSIDE EMERGENCY ELEVATORS
PART 6 ESCALATORS AND MOVING WALKS
SECTION 6.1 ESCALATORS
1001 SECTION 6.2 MOVING WALKS
1003 PART 7 DUMBWAITERS AND MATERIAL LIFTS
SECTION 7.1 POWER AND HAND DUMBWAITERS WITHOUT AUTOMATIC TRANSFER DEVICES
SECTION 7.4 MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES
SECTION 7.5 ELECTRIC MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES
SECTION 7.6 HYDRAULIC MATERIAL LIFTS WITHOUT AUTOMATIC TRANSFER DEVICES
SECTION 7.7 AUTOMATIC TRANSFER DEVICES
SECTION 7.9 ELECTRIC MATERIAL LIFTS WITH AUTOMATIC TRANSFER DEVICES
SECTION 7.10 HYDRAULIC MATERIAL LIFTS WITH AUTOMATIC TRANSFER DEVICES
SECTION 7.11 MATERIAL LIFTS WITH OBSCURED TRANSFER DEVICES
1004 PART 8 GENERAL REQUIREMENTS
SECTION 8.1 SECURITY
SECTION 8.5 ESCALATOR AND MOVING WALK SAFETY REQUIREMENT FOR SEISMIC RISK ZONE 2 OR GREATER
SECTION 8.5 ESCALATOR AND MOVING WALK SEISMIC REQUIREMENTS
1005 FIGURE 8.5.1 BALUSTRADE HANDRAIL FORCE
1007 SECTION 8.6 MAINTENANCE, REPAIR, REPLACEMENT, AND TESTING
TABLE 8.5.5 COMPONENT-BASED ALLOWABLE DESIGN STRESSES
1009 SECTION 8.7 ALTERATIONS‡
1011 SECTION 8.8 WELDING
SECTION 8.10 ACCEPTANCE INSPECTIONS AND TESTS
SECTION 8.11 PERIODIC INSPECTIONS AND WITNESSING OF TESTS
1015 TABLE N1 REQUIRED INSPECTION AND TEST INTERVALS IN “MONTHS
1016 CHAPTER K2 MODIFICATIONS TO ASME B20.1/2015, SAFETY STANDARD FOR CONVEYORS AND RELATED EQUIPMENT
4 DEFINITIONS
6 SPECIFIC SAFETY STANDARDS
SECTION 6.1 BELT CONVEYORS: FIXED IN PLACE
SECTION 6.2 GUARDING OF BUCKET CONVEYORS
SECTION 6.3 SAFETY CONSIDERATIONS FOR CHAIN CONVEYORS
SECTION 6.4 EN MASSE CONVEYORS
SECTION 6.5 FLIGHT AND APRON CONVEYORS: BULK MATERIAL
SECTION 6.6 INCLINED RECIPROCATING CONVEYORS
SECTION 6.7 LIVE ROLLER CONVEYORS: BELT OR CHAIN DRIVEN
SECTION 6.8 MOBILE CONVEYORS
SECTION 6.9 SAFETY CONSIDERATIONS FOR PORTABLE CONVEYORS, EXTENDABLE BELT CONVEYORS, AND CAR UNLOADERS
SECTION 6.10 SAFETY CONSIDERATIONS FOR PUSHER BAR CONVEYORS
SECTION 6.11 ROLLER AND WHEEL CONVEYORS
SECTION 6.12 SAFETY CONSIDERATIONS FOR SCREW CONVEYORS
SECTION 6.13 SAFETY CONSIDERATIONS FOR SHUTTLE CONVEYERS, BELT TRIPPERS, AND TRANSFER CARS
SECTION 6.14 SKIP HOISTS: BULK MATERIAL
SECTION 6.15 SLAT CONVEYORS AND ROLLER SLAT CONVEYORS
SECTION 6.16 SUSPENDED VERTICAL TRAY CONVEYORS
1017 SECTION 6.17 TOW CONVEYORS
SECTION 6.17 TOW CONVEYORS (SHOPPING CAR CONVEYORS)
SECTION 6.18 TROLLEY CONVEYORS AND POWER AND FREE CONVEYORS
SECTION 6.19 VERTICAL ARTICULATED CONVEYORS
SECTION 6.20 VERTICAL CHAIN-OPPOSED SHELF TYPE CONVEYORS
SECTION 6.21 VERTICAL RECIPROCATING CONVEYORS
1018 SECTION 6.22 MATERIAL ENCAPSULTING CONVEYORS
NON-MANDATORY APPENDIX I SPECIFICATIONS FOR DESIGN, INSTALLATION COMMISSIONING, AND PERIODIC INSPECTION OF VERTICAL RECIPROCATING CONVEYORS
CHAPTER K3 MODIFICATIONS TO ASME A17.3-2015, SAFETY CODE FOR EXISTING ELEVATORS AND ESCALATORS
PART I INTRODUCTION
SECTION 1.1 SCOPE
SECTION 1.5 ALTERATIONS, MAINTENANCE, AND INSPECTIONS AND TESTS
PART II HOISTWAYS AND RELATED CONSTRUCTION FORELECTRIC ELEVATORS
SECTION 2.1 HOISTWAYS
SECTION 2.2 MACHINE ROOMS AND MACHINERY SPACES
1019 SECTION 2.4 CLEARANCES AND RUNBYS
SECTION 2.5 PROTECTION OF SPACES BELOW HOISTWAYS
SECTION 2.6 HOISTWAY ENTRANCES
1020 SECTION 2.7 HOISTWAY-DOOR LOCKING DEVICES, PARKING DEVICES, AND ACCESS
SECTION 2.8 POWER OPERATION OF DOORS AND GATES
PART III MACHINERY AND EQUIPMENT FOR ELECTRIC ELEVATORS
SECTION 3.3 CAR FRAMES AND PLATFORMS
SECTION 3.4 CAR ENCLOSURES
1021 SECTION 3.5 SAFETIES
SECTION 3.6 SPEED GOVERNORS
SECTION 3.8 DRIVING MACHINES AND SHEAVES
1022 SECTION 3.9 TERMINAL STOPPING DEVICES
SECTION 3.10 OPERATING DEVICES AND CONTROL EQUIPMENT
1024 SECTION 3.11 EMERGENCY OPERATION AND SIGNALING DEVICES
SECTION 3.12 SUSPENSION MEANS AND THEIR CONNECTIONS
PART IV HYDRAULIC ELEVATORS
SECTION 4.2 MECHANICAL EQUIPMENT
SECTION 4.3 DRIVING MACHINES
1025 SECTION 4.5 TANKS
SECTION 4.7 OPERATING DEVICES AND CONTROL EQUIPMENT
SECTION 4.8 ADDITIONAL REQUIREMENTS FOR COUNTERWEIGHTED HYDRAULIC ELEVATORS
SECTION 4.9 ADDITIONAL REQUIREMENTS FOR ROPED HYDRAULIC ELEVATORS
PART V ESCALATORS
SECTION 5.1 CONSTRUCTION
1026 SECTION 5.3 OPERATING AND SAFETY DEVICES
PART VI DUMBWAITERS
PART VII HAND ELEVATORS
SECTION 7.0 EXISTING HAND POWERED FREIGHT ELEVATORS
SECTION 7.1 HOISTWAY, HOISTWAY ENCLOSURES, AND RELATED CONSTRUCTION
1027 SECTION 7.2 MACHINERY AND EQUIPMENT
PART VIII SIDEWALK ELEVATORS
SECTION 8.1 HOISTWAY, HOISTWAY ENCLOSURES, AND MACHINE ROOMS
SECTION 8.2 MACHINERY AND EQUIPMENT
PART IX MOVING WALKS
SECTION 9.2 PROTECTION OF SUPPORTS AND MACHINE SPACES AGAINST FIRE
1028 SECTION 9.3 CONSTRUCTION REQUIREMENTS
SECTION 9.6 OPERATING AND SAFETY DEVICES
PART X PRIVATE RESIDENCE ELEVATORS
SCOPE
1029 SECTION 10.1 HOISTWAY, HOISTWAY ENCLOSURES, AND RELATED CONSTRUCTION
SECTION 10.2 CARS
SECTION 10.3 COUNTERWEIGHTS
SECTION 10.4 SAFTETIES AND GOVERNORS
SECTION 10.5 CAR AND COUNTER WEIGHT GUIDE RAILS AND FASTENINGS
SECTION 10.6 CAR AND COUNTER WEIGHT BUFFERS
SECTION 10.7 DRIVING MACHINES, SHEAVES, AND THEIR SUPPORTS
SECTION 10.8 TERMINAL STOPPING DEVICES
SECTION 10.9 OPERATING DEVICES AND CONTROL EQUIPMENT
SECTION 10.10 EMERGENCY SIGNAL DEVICES
SECTION 10.11 LIMITATION OF LOAD, SPEED, AND RISE
SECTION 10.12 MARKING PLATES
SECTION 10.13 SUSPENSION MEANS
1030 APPENDIX L RESERVED
1032 APPENDIX M SUPPLEMENTARY REQUIREMENTS FOR ONE- AND TWO-FAMILY DWELLINGS
SECTION BC M101 GENERAL
SECTION BC M102 DEFINITIONS
SECTION BC M103 FIRE WALL SEPARATION
1033 FIGURE M103(1) PARTY WALL VERTICAL SECTION
1034 FIGURE M103(2) PARTY WALL PLAN SECTION
1036 APPENDIX N ASSISTIVE LISTENING SYSTEMS PERFORMANCE STANDARDS
SECTION BC N101 GENERAL
SECTION BC N102 INDUCTION LOOP SYSTEM
SECTION BC N103 INFRA-RED SYSTEM
SECTION BC N104 FM SYSTEM
1038 APPENDIX O RESERVED
1040 APPENDIX P RESERVED
1042 APPENDIX Q MODIFIED NATIONAL STANDARDS FOR AUTOMATIC SPRINKLER, STANDPIPE, FIRE PUMP, FIRE ALARM, AND SMOKE CONTROL SYSTEMS
SECTION BC Q101 SCOPE
SECTION BC Q102 INSTALLATION OF SPRINKLER SYSTEMS
1044 TABLE 8.16.2.4.2 SECTIONAL OR FLOOR VALVE SIZE MINIMUM SIZE OF DRAIN CONNECTION
1049 SECTION BC Q103 INSTALLATION OF SPRINKLER SYSTEMS IN ONE- AND TWO-FAMILY DWELLINGS AND MANUFACTURED HOMES
1050 ANNEXES
SECTION BC Q104 INSTALLATION OF SPRINKLER SYSTEMS IN RESIDENTIAL OCCUPANCIES
1051 ANNEXES
SECTION BC Q105 INSTALLATION OF STANDPIPE AND HOSE SYSTEMS
1061 ANNEXES
SECTION BC Q106 INSTALLATION OF STATIONARY FIRE PUMPS
1064 ANNEXES
SECTION BC Q107 INSTALLATION OF FIRE ALARMS
1070 AUXILIARY RADIO COMMUNICATIONS
1071 ANNEXES
1072 SECTION BC Q108 INSTALLATION OF SMOKE CONTROL SYSTEMS
1073 ANNEXES
1074 APPENDIX R ACOUSTICAL TILE AND LAY-IN PANEL CEILING SUSPENSION SYSTEMS
SECTION BC R101 GENERAL
SECTION BC R102 MODIFICATIONS TO ASTM C 635 – STANDARD SPECIFICATION FOR THE MANUFACTURE, PERFORMANCE, AND TESTING OF METAL SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY-IN PANEL CEILINGS
FIGURE 1A INDIRECT HUNG SUSPENSION SYSTEM
FIGURE 1B INDIRECT HUNG SUSPENSION SYSTEM
1075 FIGURE 1C FURRING BAR SUSPENSION SYSTEM
SECTION BC R103 MODIFICATIONS TO ASTM C 636 – STANDARD PRACTICE FOR INSTALLATION OF METAL CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY-IN PANELS
1076 FIGURE 1A HANGER CONNECTION DETAILS FOR CONSTRUCTION GROUPS I AND II
1077 FIGURE 1B HANGER CONNECTION DETAILS FOR CONSTRUCTION GROUPS I AND II
1080 APPENDIX S SUPPLEMENTARY FIGURES FOR LUMINOUS EGRESS PATH MARKINGS
SECTION BC S101 GENERAL
FIGURE S101.1(1) DOOR-MOUNTING OPTIONS FOR PHOTOLUMINESCENT DOOR SIGNS
1081 FIGURE S101.1(2) PHOTOLUMINESCENT MARKING AT HORIZONTAL LEADING EDGE OF STEP
FIGURE S101.1(3) PHOTOLUMINESCENT MARKING AT HORIZONTAL LEADING EDGE OF LANDING
1082 FIGURE S101.1(4) PHOTOLUMINESCENT MARKINGS ON HANDRAILS
1083 FIGURE S101.1(5) FLOOR-MOUNTING OPTION FOR PHOTOLUMINESCENT PERIMETER DEMARCATION LINES
1084 FIGURE S101.1(6) OBSTACLE MOUNTING OPTIONS PHOTOLUMINESCENT PERIMETER DEMARCATION LINES
1085 FIGURE S101.1(7) WALL-MOUNTING OPTION FOR PHOTOLUMINESCENT PERIMETER DEMARCATION LINES
1086 FIGURE S101.1(8) WALL-MOUNTING OPTION FOR PHOTOLUMINESCENT PERIMETER DEMARCATION LINES THAT ARE NOT PROVIDED WITH DOOR FRAME MARKING
FIGURE S101.1(9) DIRECTIONAL SIGNAGE
FIGURE S101.1(10) NO-EXIT SIGNAGE
1087 FIGURE S101.1(11) PHOTOLUMINESCENT MARKING OF INTERMEDIATE EXIT DOOR WITH PUSH BAR
FIGURE S101.1(12) PHOTOLUMINESCENT MARKING OF FINAL EXIT DOOR WITH DOOR HANDLE
1088 FIGURE S101.1(13) PHOTOLUMINESCENT FINAL EXIT DOOR SIGNS
FIGURE S101.1(14) POSITIVE AND NEGATIVE OPTIONS FOR PHOTOLUMINESCENT DIRECTIONAL SIGNS
FIGURE S101.1(15) POSITIVE AND NEGATIVE OPTIONS FOR PHOTOLUMINESCENT DOOR-MOUNTED DOOR SIGNS
1090 INDEX RESERVED
1092 ICC DIGITAL CODES PREMIUM
1093 ICC ASSESSMENT CENTER
1094 ICC LEARNING CENTER
1095 ICC EVALUATION SERVICE
]]>
NY NYC GeneralAdministrativeProvisions 2022 1stptg ?u=/product/publishers/ny/ny-nyc-generaladministrativeprovisions-2022-1stptg/ Sun, 20 Oct 2024 06:12:39 +0000 New York City General Administrative Provisions for Construction Codes
Published By Publication Date Number of Pages
NY 2022
]]>
Contains general administrative provisions applicable to all 2022 New York City Construction Codes, including chapters on Administration, Enforcement, Maintenance of Buildings, Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, and Miscellaneous Provisions. Effective date: November 7, 2022.

PDF Catalog

PDF Pages PDF Title
1 2022 NEW YORK CITY GENERAL ADMINISTRATIVE PROVISIONS FOR CONSTRUCTION CODES
2 2022 NEW YORK CITY GENERAL ADMINISTRATIVE PROVISIONS FOR CONSTRUCTION CODES TITLE PAGE
3 COPYRIGHT
4 DEDICATION
6 NEW YORK CITY CONSTRUCTION CODES PREFACE
8 ACKNOWLEDGEMENTS
16 TITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES
18 TABLE OF CONTENTS
30 CHAPTER 1 ADMINISTRATION
ARTICLE 101 GENERAL
101.1 TITLE
101.2 INTENT
101.3 CODES
101.4 EFFECTIVE DATE
32 101.5 DEFINITIONS
38 ARTICLE 102 APPLICABILITY
102.1 GENERAL
102.2 OTHER LAWS
102.3 SEPARABILITY
102.4 EXISTING BUILDINGS
102.5 RESERVED
102.6 APPENDICES
102.7 REFERENCES IN OTHER LAWS
ARTICLE 103 DUTIES AND POWERS OF COMMISSIONER OF BUILDINGS
103.1 JURISDICTION
39 103.2 INTERPRETATION
103.3 VARIATIONS
103.4 APPEALS
103.5 SEAL; JUDICIAL NOTICE
40 103.6 PROOFS, AFFIDAVITS AND OATHS
103.7 COOPERATION OF OTHER DEPARTMENTS
103.8 MATTERS NOT PROVIDED FOR
103.9 ADDITIONAL TESTS
103.10 SUPPORTING DOCUMENTATION FOR MATERIALS
103.11 APPLICATIONS AND PERMITS
103.12 IDENTIFICATION
103.13 RIGHT OF ENTRY
103.14 DEPARTMENT RECORDS
103.15 INSURANCE
41 103.16 INSPECTIONS OF EXISTING BUILDINGS, STRUCTURES, SIGNS, SERVICE EQUIPMENT AND CONSTRUCTION MACHINERY AND EQUIPMENT
103.17 CERTAIN OUTSIDE WORK, EMPLOYMENT AND FINANCIAL INTERESTS OF DEPARTMENT EMPLOYEES PROHIBITED
103.18 INVESTIGATION OF COMPLAINTS
103.19 ADDITION, MODIFICATION, AND DELETION OF REFERENCED STANDARDS
103.20 EXISTING RULES CONTINUED
103.21 INCIDENT LISTS
42 103.22 OUTREACH ON SECURITY GRILLE VISIBILITY REQUIREMENTS
103.23 MANUAL ON FLOOD CONSTRUCTION AND PROTECTION STANDARDS
103.24 ELECTRONIC SUBMISSIONS
103.25 HOTEL DEVELOPMENT PLANS
103.26 REPORTING TO THE FEDERAL OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
103.27 DISCLOSURE OF BUILDING OCCUPANCY STATUS FOR BUILDINGS SUBJECT TO PERMIT
103.28 SITE SAFETY TRAINING (SST) TASK FORCE
43 103.29 REPORTING REGARDING IMPLEMENTATION OF SECTION 3321 OF THE NEW YORK CITY BUILDING CODE
44 103.30 REAL TIME ENFORCEMENT UNIT
103.31 REPORT ON SITE SAFETY MANAGER AND COORDINATOR CERTIFICATIONS
45 103.32 EDUCATION AND OUTREACH REGARDING SINGLE-OCCUPANT TOILET ROOM REQUIREMENTS
103.33 OFFICE OF ALTERNATIVE ENERGY
46 103.34 ELECTRONIC MAIL ADDRESS
103.35 ELECTRONIC MAIL NOTICE OF CONSTRUCTION PROJECT UPDATES
103.36 BIRD FRIENDLY DESIGN AND CONSTRUCTION REQUIREMENTS
ARTICLE 104 CONSTRUCTION DOCUMENTS
104.1 GENERAL
104.2 APPLICATION FOR APPROVAL OF CONSTRUCTION DOCUMENTS
50 104.3 AMENDED CONSTRUCTION DOCUMENTS
104.4 PLACE OF FILING
104.5 FEES
104.6 APPLICANT
51 104.7 SUBMITTAL OF CONSTRUCTION DOCUMENTS
52 TABLE 104.7.6.1
TABLE 104.7.6.2a
TABLE 104.7.6.3a
TABLE 104.7.6.4a
TABLE 104.7.6.5a
54 104.8 APPLICATIONS
104.9 COASTAL ZONES AND WATER-SENSITIVE INLAND ZONES
55 104.10 NOTIFICATION TO THE NEW YORK CITY TRANSIT AUTHORITY, THE METROPOLTAN TRANSPORTATION AUTHORITY AND THE PORT AUTHORITY OF NEW YORK AND NEW JERSEY
104.11 CONSTRUCTION DOCUMENTS FOR SITES THAT ARE COVERED DEVELOPMENT PROJECTS AS DEFINED IN SECTION 24-541 OF THE ADMINISTRATIVE CODE
56 104.12 RETENTION OF CONSTRUCTION AND SUBMITTAL DOCUMENTS
104.13 CONSTRUCTION DOCUMENTS FOR EXTENSION, ALTERATION OR RELOCATION OF AN EXISTING CHIMNEY OR VENT
ARTICLE 105 PERMITS
105.1 GENERAL
58 105.2 CLASSIFICATION OF WORK PERMITS
59 105.3 SEPARATE PERMITS REQUIRED
105.4 WORK EXEMPT FROM PERMIT
61 105.5 APPLICATION FOR PERMIT
105.6 FEES
105.7 TIME LIMITATION OF APPLICATIONS
105.8 VALIDITY OF PERMIT
62 105.9 EXPIRATION
105.10 SUSPENSION OR REVOCATION OF PERMIT
105.11 POSTING OF PERMIT
105.12 CONDITIONS OF PERMIT
64 ARTICLE 106 ASBESTOS
106.1 ASBESTOS CERTIFICATION REQUIRED
106.2 CONSTRUCTION AND MAINTENANCE OF ASBESTOS CONTAINMENT STRUCTURES AND OTHER TEMPORARY STRUCTURES OR WORK REQUIRED FOR ASBESTOS ABATEMENT ACTIVITIES
106.3 PERMIT EXEMPTION
106.4 DEFINITIONS
ARTICLE 107 ALTERATION OR DEMOLITION OF SINGLE ROOM OCCUPANCY MULTIPLE DWELLINGS
107.1 GENERAL
107.2 DEFINITIONS
65 107.3 COVERED CATEGORIES OF WORK
107.4 REQUIRED SUBMITTAL DOCUMENTS
107.5 FILING PROCESS
107.6 TIME PERIOD FOR ACCEPTANCE OR REJECTION
107.7 DENIAL OF CERTIFICATION
107.8 REQUEST FOR STOP-WORK OR RESCISSION
66 107.9 EFFECT OF DENIAL OR RESCISSION
ARTICLE 108 PAVEMENT PLAN
108.1 GENERAL
108.2 PAVEMENT PLAN REQUIRED
108.3 IMPROVEMENT OF STREETS
ARTICLE 109 FIRE PROTECTION PLAN
109.1 FIRE PROTECTION PLAN REQUIRED FOR COVERED BUILDINGS
109.2 COVERED BUILDINGS
67 109.3 SCOPE
ARTICLE 110 SITE SAFETY PLAN
110.1 SITE SAFETY PLAN
110.2 PHASED SITE SAFETY PLANS
68 ARTICLE 111 TEMPORARY STRUCTURES AND USES
111.1 GENERAL
111.2 CONFORMANCE
111.3 TERMINATION OF APPROVAL
111.4 APPLICATION PROCESSING
111.5 FEES
111.6 PLACE OF ASSEMBLY
ARTICLE 112 FEES
112.1 PAYMENT OF FEES
112.2 SCHEDULE OF PERMIT FEES
69 TABLE 28-112.2
70 TABLE 28-112.2—continued
71 TABLE 28-112.2—continued
72 TABLE 28-112.2—continued
73 TABLE 28-112.2—continued
74 TABLE 28-112.2—continued
75 TABLE 28-112.2—continued
112.3 BUILDING PERMIT VALUATIONS
112.4 WORK COMMENCING BEFORE PERMIT ISSUANCE
112.5 RELATED FEES
112.6 REFUNDS AND REBATES
76 112.7 INSPECTION AND REPORT FILING FEES
112.8 SPECIAL FEES
77 TABLE 28-112.7.1
78 TABLE 28-112.7.1—continued
TABLE 28-112.7.2
TABLE 28-112.7.3
TABLE 28-112.7.4
79 TABLE 28-112.8
80 TABLE 28-112.8—continued
81 112.9 LIEN ON PREMISES FOR UNPAID FEE OR OTHER CHARGE
112.10 WAIVER OF APPLICATION, PERMIT AND INSPECTION FEES FOR CERTAIN WORK ARISING OUT OF THE STORM THAT OCCURED ON OCTOBER 29 AND 30, 2012
82 112.11 WAIVER OF APPLICATION, PERMIT AND INSPECTION FEES FOR WORK FUNDED UNDER THE “BUILD IT BACK” PROGRAM
112.12 REDUCTION IN FEES OR PENALTIES FOR SPONSORING SITE SAFETY TRAINING
112.13 PERMIT FILING FEES FOR ONE-, TWO- OR THREE-FAMILY DWELLINGS DAMAGED BY A FIRE
ARTICLE 113 MATERIALS
113.1 GENERAL
113.2 USE OF MATERIALS
83 113.3 APPROVAL PROCEDURE
113.4 LABELING
84 113.5 VOLATILE ORGANIC COMPOUNDS EMISSIONS IN CARPET AND CARPET CUSHION
ARTICLE 114 APPROVED AGENCIES
114.1 GENERAL
114.2 WRITTEN EVALUATION BY APPROVED AGENCY
114.3 RECORDS
114.4 RE-AUTHORIZATION OF APPROVED AGENCIES
114.5 DISQUALIFICATION
ARTICLE 115 SPECIAL INSPECTION AGENCIES AND SPECIAL INSPECTORS
115.1 GENERAL
115.2 DISQUALIFICATION
115.3 RECORDS
ARTICLE 116 INSPECTIONS AND SIGN-OFF OF COMPLETED WORK
116.1 GENERAL
85 116.2 TYPES OF INSPECTIONS
86 116.3 INSPECTION REQUESTS
116.4 SIGN-OFF OF COMPLETED WORK
87 116.5 PAYMENT OF OUTSTANDING PENALTIES
116.6 FABRICATOR APPROVAL
116.7 POST-CONSTRUCTION STORMWATER MANAGEMENT FACILITIES
ARTICLE 117 PLACES OF ASSEMBLY
117.1 PLACE OF ASSEMBLY CERTIFICATE OF OPERATION
88 117.2 TEMPORARY PLACE OF ASSEMBLY CERTIFICATE OF OPERATION
117.3 DURATION OF CERTIFICATE
117.4 SECURITY GUARDS
117.5 OUTDOOR PLACES OF ASSEMBLY
ARTICLE 118 CERTIFICATES OF OCCUPANCY
118.1 GENERAL PROVISIONS
118.2 NEW BUILDINGS OR OPEN LOTS
118.3 COMPLETED BUILDINGS OR OPEN LOTS
90 118.4 APPLICATIONS FOR CERTIFICATES OF OCCUPANCY
118.5 REVIEW OF APPLICATIONS FOR CERTIFICATIONS OF OCCUPANCY
118.6 ISSUANCE OF CERTIFICATE OF OCCUPANCY
91 118.7 PAVEMENT PLAN
118.8 SANITARY/STORM WATER DRAINAGE
118.9 FIRE PROTECTION PLAN
118.10 ELECTRICAL WORK
118.11 CERTIFICATES OF COMPLIANCE
118.12 PLACE OF ASSEMBLY CERTIFICATE OF OPERATION
118.13 CERTIFICATES OF OCCUPANY FOR AIR-INFLATED STRUCTURES, AIR-SUPPORTED STRUCTURES, AND TENTS
118.14 PAYMENT OF OUTSTANDING FEE AND PENALTIES
118.15 TEMPORARY CERTIFICATES OF OCCUPANCY
92 118.16 AMENDED CERTIFICATE OF OCCUPANCY
118.17 REVOCATION OF CERTIFICATES OF OCCUPANCY
118.18 RECORD OF CERTIFICATES
118.19 POSTING OF CERTIFICATES OF OCCUPANCY
118.20 PARTIAL CERTIFICATE OF OCCUPANCY
118.21 LIVE LOADS POSTED
93 118.22 POST-CONSTRUCTION STORMWATER MANAGEMENT FACILITIES
118.23 EXTENSION, ALTERATION OR RELOCATION OF CHIMNEYS AND VENTS
ARTICLE 119 SERVICE UTILITIES
119.1 CONNECTION OF SERVICE UTILITIES
119.2 TEMPORARY CONNECTION
119.3 AUTHORITY TO DISCONNECT UTILITY SERVICE
119.4 NOTIFICATION OF GAS SHUT-OFF OR NON-RESTORATION AFTER INSPECTION
ARTICLE 120 TENANT PROTECTION PLAN
120.1 TENANT PROTECTION PLAN
95 120.2 PHASED TENANT PROTECTION PLANS
120.3 CONTRACTOR STATEMENT
96 CHAPTER 2 ENFORCEMENT
ARTICLE 201 GENERAL
201.1 UNLAWFUL ACTS
201.2 CLASSIFICATION OF VIOLATIONS
97 201.3 METHODS OF ENFORCEMENT
201.4 AGGRAVATING AND MITIGATING FACTORS
ARTICLE 202 CIVIL PENALTIES
202.1 CIVIL PENALTIES
99 202.2 CONTINUING VIOLATIONS
202.3 INCREASED CIVIL PENALTIES FOR CONSTRUCTION SITES WITH EXCESSSIVE VIOLATIONS
202.4 MAXIMUM CIVIL PENALTY FOR IMMEDIATELY HAZARDOUS VIOLATION OF CHAPTER 33 OF THE NEW YORK CITY BUILDING CODE THAT RESULTS IN DEATH OR SERIOUS PHYSICAL INJURY
100 ARTICLE 203 CRIMINAL PENALTIES
203.1 CRIMINAL FINES AND IMPRISONMENT
203.2 CONTINUING VIOLATIONS
101 ARTICLE 204 ENVIRONMENTAL CONTROL BOARD
204.1 GENERAL
102 204.2 ORDER TO CERTIFY CORRECTION
204.3 FAILURE OF PROOF
204.4 FAILURE TO CERTIFY THE CORRECTION OF A VIOLATION
103 204.5 FALSE STATEMENTS IN CERTIFICATION OF CORRECTION
204.6 ENFORCEMENT OF ENVIRONMENTAL CONTROL BOARD JUDGMENTS AS A TAX LIEN
104 ARTICLE 205 CIVIL JUDICIAL PROCEEDINGS
205.1 CIVIL JUDICIAL ENFORCEMENT
105 ARTICLE 206 CRIMINAL JUDICIAL PROCEEDINGS
206.1 CRIMINAL JUDICIAL ENFORCEMENT
ARTICLE 207 PEREMPTORY ORDERS
207.1 CONTENTS AND SERVICE
207.2 STOP WORK ORDERS
106 207.3 PUBLIC NUISANCE
207.4 VACATE ORDER
107 207.5 CEASE USE ORDERS FOR SERVICE EQUIPMENT
ARTICLE 208 COMMISSIONER’S REQUEST FOR CORRECTIVE ACTION
208.1 COMMISSIONER’S REQUEST FOR CORRECTIVE ACTION
208.2 ISSUING REQUESTS FOR CORRECTIVE ACTION TO ONE- AND TWO-FAMILY HOMES
208.3 OTHER REMEDIES NOT PRECLUDED
108 ARTICLE 209 COMMISSIONER’S ORDER TO CORRECT UNLAWFUL USE OR CONDITION
209.1 GENERAL
209.2 CONTENTS AND SERVICE OF ORDER
ARTICLE 210 ILLEGAL CONVERSIONS
210.1 ILLEGAL RESIDENTIAL CONVERSIONS
210.2 ILLEGAL INDUSTRIAL OR MANUFACTURING CONVERSIONS
210.3 ILLEGAL CONVERSIONS OF DWELLING UNITS FROM PERMANENT RESIDENCES
109 210.4 UNLAWFUL ADVERTISEMENT FOR CERTAIN OCCUPANCIES
ARTICLE 211 FALSE STATEMENTS
211.1 FALSE STATEMENTS IN CERTIFICATES, FORMS, WRITTEN STATEMENTS, APPLICATIONS, REPORTS, OR CERTIFICATES OF CORRECTION
211.2 FALSELY IMPERSONATING A DEPARTMENT OFFICER, INSPECTOR OR EMPLOYEE
110 211.3 IDENTIFYING UNLAWFUL STATEMENTS
ARTICLE 212 ABATEMENT OF PUBLIC NUISANCE CAUSED BY CERTAIN ILLEGAL OCCUPANCIES
212.1 ABATEMENT OF PUBLIC NUISANCES CAUSED BY ILLEGAL COMMERCIAL OR MANUFACTURING OCCUPANCY IN RESIDENCE DISTRICTS AND CERTAIN OTHER ZONING DISTRICTS
212.2 ORDER OF CLOSURE
212.3 NOTICE OF HEARING
212.4 SERVICE OF NOTICE OF HEARING
111 212.5 CONDUCT OF HEARING BY OFFICE OF ADMINISTRATIVE TRIALS AND HEARINGS
212.6 LACK OF KNOWLEDGE NOT A DEFENSE
212.7 CLOSURE NOT AN ACT OF POSSESSION
212.8 POSTING OF ORDER OF CLOSURE
212.9 ENFORCEMENT OF ORDER OF CLOSURE
212.10 RESCISSION OF ORDER OF CLOSURE
212.11 VIOLATION OF CLOSURE ORDER
ARTICLE 213 PENALTY FOR WORK WITHOUT A PERMIT
213.1 DEPARTMENT PENALTY FOR WORK WITHOUT A PERMIT
112 213.2 WAIVER
213.3 PAYMENT OF PENALTY REQUIRED BEFORE ISSUANCE
213.4 PROCEDURE
213.5 WATCH LIST OF CONTRACTORS PERFORMING WORK WITHOUT REQUIRED PERMIT
213.6 ENHANCED PENALTIES FOR OTHER VIOLATIONS
213.7 INSPECTION FEES
ARTICLE 214 ORDER TO SEAL, SECURE AND CLOSE
214.1 ORDER TO SEAL, SECURE AND CLOSE
113 214.2 ACCESS TO SEALED PREMISES
214.3 ADDITIONAL PENALTIES FOR HARM OR INJURY FROM VIOLATION OF ORDER TO SEAL, SECURE AND CLOSE
114 ARTICLE 215 EMERGENCY POWERS OF THE COMMISSIONER
215.1 EMERGENCY WORK
215.2 STOPPING WORK AND SECURING STRUCTURES
215.3 VACATING STRUCTURES
215.4 VIOLATIONS OF PROTECTIVE MEASURES DURING CONSTRUCTION OR DEMOLITION
215.5 INVESTIGATION OF ACCIDENTS OR OTHER EMERGENCY CONDITIONS
115 215.6 CLOSING STREETS TEMPORARILY
215.7 RECOVERY OF BODIES FROM WRECKED STRUCTURES
215.8 NON-COMPLIANCE WITH ORDERS; EXECUTION OF WORK BY DEPARTMENT
ARTICLE 216 UNSAFE BUILDINGS
216.1 CONDITIONS CONSTITUTING AN UNSAFE BUILDING OR STRUCTURE
216.2 RECORD AND NOTICE OF UNSAFE BUILDING, STRUCTURE OR PREMISES
216.3 NOTICE OF SURVEY AND SUMMONS AND ORDER
216.4 METHOD OF SERVICE
216.5 OWNER ABATEMENT OF UNSAFE OR DANGEROUS CONDITIONS
216.6 SURVEY
116 216.7 COURT PROCEEDING
216.8 EXECUTION OF PRECEPT
117 216.9 RETURN OF PRECEPT AND REIMBURSEMENT OF CITY
216.10 JUDGMENT LIEN
216.11 TAX LIEN
ARTICLE 217 BUILDINGS AND STRUCTURES THAT ARE POTENTIALLY COMPROMISED
217.1 BUILDINGS AND STRUCTURES THAT ARE POTENTIALLY STRUCTURALLY COMPROMISED
118 ARTICLE 218 SAFETY COMPLIANCE OFFICER
218.1 DEFINITION
218.2 SAFETY COMPLIANCE OFFICER
218.3 APPOINTMENT OF A SAFETY COMPLIANCE OFFICER
218.4 QUALIFICATIONS
218.5 COMPLIANCE MONITORING
218.6 COST OF A SAFETY COMPLIANCE OFFICER
218.7 THE SCO SHALL DOCUMENT WITH PHOTOGRAPHS OR OTHER MEANS ANY VIOLATION OF THE CODE
119 218.8 RECORDS
ARTICLE 219 FAILURE TO CERTIFY CORRECTION OF CERTAIN IMMEDIATELY HAZARDOUS VIOLATIONS
219.1 DEPARTMENT PENALTY FOR FAILURE TO CERTIFY CORRECTION
219.2 RE-INSPECTION
219.3 FALSE CERTIFICATIONS OF CORRECTION
219.4 NOTICE TO THE DEPARTMENT OF HOUSING PRESERVATION AND DEVELOPMENT FOR CERTAIN ELEVATOR-RELATED VIOLATIONS
120 219.5 DEFINITION
219.6 OTHER REMEDIES NOT PRECLUDED
122 CHAPTER 3 MAINTENANCE OF BUILDINGS
ARTICLE 301 GENERAL
301.1 OWNER’S RESPONSIBILITIES
301.2 FILING OF REPORTS IN WRITING OR ELECTRONICALLY
ARTICLE 302 MAINTENANCE OF EXTERIOR WALLS
302.1 GENERAL
302.2 INSPECTION REQUIREMENTS
302.3 IMMEDIATE NOTICE OF UNSAFE CONDITION
302.4 REPORT OF CRITICAL EXAMINATION
302.5 REPAIR OF EXTERIOR WALLS, UNSAFE CONDITION
123 302.6 SAFE CONDITION WITH A REPAIR AND MAINTENANCE PROGRAM
ARTICLE 303 PERIODIC BOILER INSPECTIONS
303.1 GENERAL
303.2 ANNUAL INSPECTIONS
303.3 QUALIFICATIONS OF BOILER INSPECTORS
303.4 STAGGERED INSPECTION CYCLES
303.5 REPAIR OF DEFECTS
303.6 REPORTING AN UNSAFE OR HAZARDOUS CONDITION
303.7 OWNER’S ANNUAL BOILER INSPECTION REPORT
303.8 SCOPE OF INSPECTION
124 303.9 REMOVAL OR DISCONTINUANCE NOTICE
303.10 ADDITIONAL INSPECTIONS
303.11 FEES
ARTICLE 304 ELEVATORS AND CONVEYING SYSTEMS
304.1 GENERAL
304.2 ELEVATORS, ESCALATORS, MOVING WALKWAYS, MATERIAL LIFTS, MAN LIFTS AND DUMBWAITERS
304.3 PLATFORM LIFTS, STAIRWAY CHAIR LIFTS AND VERTICAL RECIPROCATING CONVEYORS (VRC’s)
304.4 AMUSEMENT DEVICES
304.5 FREQUENCY OF INSPECTION AND TESTING
304.6 INSPECTION AND TESTING PROCESS
125 304.7 REQUIRED CONTRACT
126 304.8 FEES
304.9 ADDITIONAL INSPECTIONS
304.10 OCCUPANT NOTIFICATION FOR ELEVATOR WORK
ARTICLE 305 RETAINING WALLS, PARTITION FENCES AND OTHER SITE STRUCTURES
305.1 RETAINING WALLS, PARTITION FENCES AND OTHER SITE STRUCTURES
305.2 RETAINING WALLS REQUIRED
305.3 SPECIAL AGREEMENT
305.4 MAINTENANCE, INSPECTION AN D REPAIR OF RETAINING WALLS
127 305.5 REMOVAL OF RETAINING STRUCTURES
ARTICLE 306 PARTY WALLS
306.1 RESPONSIBILITY FOR PARTY WALLS
128 306.2 SAFEGUARDS DURING CONSTRUCTION OR DEMOLITION
ARTICLE 307 WORKPLACE EXITS
307.1 OBSTRUCTION OF WORKPLACE EXITS PROHIBITED
307.2 UNANNOUNCED INSPECTIONS OF WORKPLACES BY FIRE DEPARTMENT
307.3 RETALIATION
ARTICLE 308 ENERGY AUDITS AND RETRO-COMMISSIONING OF BASE BUILDING SYSTEMS
308.1 DEFINITIONS
130 308.2 ENERGY AUDITS REQUIRED
131 308.3 RETRO-COMMISSIONING REQUIRED
132 308.4 ENERGY EFFICIENCY REPORT REQUIRED
133 308.5 CONTENT OF ENERGY EFFICIENCY REPORT
308.6 NOTIFICATION BY THE DEPARTMENT OF FINANCE
308.7 RULES
ARTICLE 309 BENCHMARKING ENERGY AND WATER USE AND DISCLOSURE OF ENERGY EFFICIENCY SCORES AND GRADES
309.1 GENERAL
309.2 DEFINITIONS
134 309.3 BENCHMARKING REQUIRED FOR CITY BUILDINGS
309.4 BENCHMARKING REQUIRED FOR COVERED BUILDINGS OTHER THAN CITY BUILDINGS
135 309.5 DIRECT UPLOAD
309.6 SUSPENSION
309.7 NOTIFICATION AND TRANSMISSION OF INFORMATION
309.8 DISCLOSURE
309.9 REPORT
309.10 RULES
309.11 BENCHMARKING ASSISTANCE
136 309.12 ENERGY FFICIENCY SCORES AND ENERGY EFFICIENCY GRADES
309.13 OUTREACH TO BUILDING OWNERS REGARDING MAKING ENERGY EFFICIENCY IMPROVEMENTS
ARTICLE 310 REQUIRED UPGRADE OF LIGHTING SYSTEMS
310.1 GENERAL
310.2 DEFINITIONS
137 310.3 UPGRADE OF LIGHTING SYSTEM OF COVERED BUILDINGS REQUIRED
ARTICLE 311 INSTALLATION OF ELECTRICAL SUB-METERS IN TENANT SPACES
311.1 GENERAL
311.2 DEFINITIONS
311.3 SUB-METERS REQUIRED FOR COVERED TENANT SPACES
311.4 MONTHLY STATEMENTS
138 311.5 REPORTS
ARTICLE 312 CARBON MONOXIDE AND SMOKE ALARMS
312.1 GENERAL
312.2 PERIODIC REPLACEMENT OF CARBON MONOXIDE ALARMS
312.3 AUDIBLE NOTIFICATION OF EXPIRATION OF USEFUL LIFE OF CARBON MONOXIDE ALARMS
312.4 PERIODIC REPLACEMENT OF SMOKE ALARMS
312.5 AUDIBLE NOTIFICATION OF EXPIRATION OF USEFUL LIFE OF SMOKE ALARMS
312.6 LOCATION OF SMOKE ALARMS AND SMOKE DETECTORS
ARTICLE 313 ACCESSIBILITY
313.1 RETROACTIVE REQUIREMENT FOR DIRECTIONAL SIGNAGE AT BUILDING ENTRANCES
313.2 RETROACTIVE REQUIREMENT FOR ACCESSIBLE BUILDING ENTRANCES
313.3 RETROACTIVE REQUIREMENT FOR SIGNAGE AND SAFETY REQUIREMENTS FOR PORTABLE RAMPS AT INACCESSIBLE BUILDING ENTRANCES WHERE SUCH RAMPS ARE PERMISSIBLE
139 ARTICLE 314 RESERVED
ARTICLE 315 RETROACTIVE REQUIREMENTS
315.1 GENERAL
315.2 FIRE PROTECTION SYSTEMS
315.3 SUSTAINABILITY
315.4 ELEVATOR SAFETY
140 315.5 FUEL GAS SYSTEMS
315.6 ACCESSIBILITY
315.7 BUILDING SECURITY
315.8 RESILIENCY
141 315.9 SINGLE-OCCUPANT TOILET ROOMS
315.10 SELF-CLOSING DOORS
315.11 BUILDINGS THAT ARE EQUIPPED WITH A FIRE ALARM SYSTEM AND THAT CONTAIN GROUP A-1, A-2, A-3, GROUP B OR GROUP M OCCUPANCIES
ARTICLE 316 INSULATION OF CONCEALED PIPES EXPOSED DURING ALTERATION OR REPAIR
316.1 REQUIRED INSULATION OF CERTAIN CONCEALED PIPING EXPOSED DURING ALTERATION OR REPAIR
ARTICLE 317 COOLING TOWERS
317.1 GENERAL
317.2 DEFINITIONS
317.3 REGISTRATION
142 317.4 INSPECTING, CLEANING, DISINFECTING AND TESTING
317.5 ANNUAL CERTIFICATION
317.6 FEES
317.7 ENFORCEMENT
ARTICLE 318 PERIODIC INSPECTION OF GAS PIPING SYSTEMS
318.1 GENERAL
318.2 FREQUENCY OF INSPECTION
318.3 INSPECTION PROCESS
144 318.4 FEES
318.5 ENFORCEMENT
ARTICLE 319 MAINTENANCE AND REMOVAL OF SMALL WIND TURBINES
319.1 MAINTENANCE
319.2 REMOVAL
ARTICLE 320 BUILDING ENERGY AND EMISSIONS LIMITS
320.1 DEFINITIONS
145 320.2 ADVISORY BOARD
146 320.3 BUILDING EMISSIONS LIMITS
150 320.4 ASSISTANCE
320.5 OUTREACH AND EDUCATION
320.6 PENALTIES
151 320.7 ADJUSTMENT TO APPLICABLE ANNUAL BUILDING EMISSIONS LIMIT
320.8 ADJUSTMENT TO APPLICABLE ANNUAL BUILDING EMISSIONS LIMIT FOR CALENDAR YEARS 2024-2029
152 320.9 ADJUSTMENT TO APPLICABLE ANNUAL BUILDING EMISSIONS LIMIT FOR NOT-FOR-PROFIT HOSPITALS AND HEALTHCARE FACILTIES
320.10 FEE SCHEDULE
320.11 CARBON TRADING STUDY
ARTICLE 321 ENERGY CONSERVATION MEASURE REQUIREMENTS FOR CERTAIN BUILDINGS
321.1 DEFINITIONS
153 321.2 REQUIRED ENERGY CONSERVATION MEASURES FOR CERTAIN BUILDINGS
321.3 REPORTS
ARTICLE 322 MAINTENANCE AND REMOVAL OF LARGE WIND TURBINES
322.1 MAINTENANCE
322.2 REMOVAL
322.3 LOCKING BEFORE HURRICANE OR STRONG WIND CONDITIONS
322.4 LIGHTING
154 ARTICLE 323 PERIODIC INSPECTION OF PARKING STRUCTURES
323.1 GENERAL
323.2 DEFINITIONS
323.3 CONDITION ASSESSMENT
323.4 ANNUAL PARKING STRUCTURE OBSERVATION
323.5 REPORT OF CONDITION ASSESSMENT
323.6 FEES
323.7 IMMEDIATE NOTICE OF UNSAFE CONDITION
155 323.8 REPAIR OF PARKING STRUCTURE, UNSAFE CONDITION
323.9 SAFE WITH REPAIR AND/OR ENGINEERING MONITORING
ARTICLE 324 PERIODIC INSPECTIONS OF DRY FLOODPROOFING
324.1 GENERAL
324.2 ANNUAL INSPECTION OF COVERED DRY FLOODPROOFING SYSTEM
324.3 TRIENNIAL FULL-SCALE DEPLOYMENT INSPECTION
156 ARTICLE 325 ANNUAL INSPECTIONS TO PREVENT CONTAMINATION OF MECHANICAL SYSTEMS
325.1 GENERAL
325.2 ANNUAL INSPECTION OF COVERED BUILDINGS
158 CHAPTER 4 LICENSING AND REGISTRATION OF BUSINESSES, TRADES AND OCCUPATIONS ENGAGED IN BUILDING WORK
ARTICLE 401 GENERAL
401.1 APPLICATION
401.2 GENERAL REQUIREMENTS FOR ALL LICENSES
401.3 DEFINITIONS
160 401.4 REQUIREMENT OF LICENSE
401.5 APPLICATION AND CONDITIONS
401.6 QUALIFICATIONS OF APPLICANT
401.7 EXAMINATION OF APPLICANT
401.8 INVESTIGATION OF APPLICANT
401.9 INSURANCE
161 401.10 ISSUANCE OF LICENSE AND SEAL, WHERE APPLICABLE, OR CERTIFICATE OF COMPETENCE
401.11 TERM OF LICENSE
401.12 RENEWAL OF LICENSE OR CERTIFICATE OF COMPETENCE
401.13 LATE RENEWAL
401.14 CONTINUING EDUCATION
162 401.15 SCHEDULE OF FEES
§28-401.15 SCHEDULE OF FEES‡
163 §28-401.15 SCHEDULE OF FEES—continued
401.16 RESTRICTIONS ON USE
401.17 USE ON BEHALF OF A BUSINESS
401.18 NEW YORK CITY LOCATION REQUIRED
164 401.19 SUSPENSION OR REVOCATION OF LICENSE OR CERTIFICATE OF COMPETENCE
165 401.20 COOPERATION REQUIRED
401.21 JUDICIAL REVIEW OF DETERMINATIONS
401.22 DEACTIVATION OF LICENSE
ARTICLE 402 SITE SAFETY MANAGER CERTIFICATE
402.1 CERTIFICATE REQUIRED
166 402.2 QUALIFICATIONS
402.3 FITNESS TO PERFORM WORK
167 ARTICLE 403 SITE SAFETY COORDINATOR CERTIFICATE
403.1 CERTIFICATE REQUIRED
403.2 QUALIFICATIONS
403.3 FITNESS TO PERFORM WORK
ARTICLE 404 RIGGER LICENSE
404.1 RIGGER LICENSE REQUIRED
168 404.2 CLASSIFICATION
404.3 QUALIFICATIONS
169 404.4 ADDITIONAL REQUIREMENTS
ARTICLE 405 HOISTING MACHINE OPERATOR LICENSE
405.1 HOISTING MACHINE OPERATOR LICENSE REQUIRED
405.2 CLASSIFICATION
170 405.3 EXPERIENCE QUALIFICATIONS
405.4 FITNESS TO PERFORM WORK
405.5 INSURANCE EXEMPTION
405.6 CERTIFICATION REQUIRED
ARTICLE 406 CONCRETE TESTING LABORATORY LICENSE
406.1 CONCRETE TESTING LABORATORY LICENSE REQUIRED
406.2 QUALIFICATIONS
171 406.3 ADDITIONAL REQUIREMENTS
406.4 NO EXAMINATION REQUIRED
ARTICLE 407 WELDER LICENSE
407.1 WELDER LICENSE REQUIRED
407.2 QUALIFICATIONS
407.3 FITNESS TO PERFORM WORK
407.4 INSURANCE EXEMPTION
ARTICLE 408 MASTER PLUMBER LICENSE
408.1 MASTER PLUMBER LICENSE REQUIRED
408.2 SEAL
408.3 ADDITIONAL QUALIFICATIONS
172 408.4 CERTIFICATE OF COMPETENCE, LICENSE AND SEAL
408.5 SURRENDER OF LICENSE OR SEAL
408.6 MASTER PLUMBER BUSINESS REQUIRED
173 408.7 FITNESS TO PERFORM WORK
ARTICLE 409 JOURNEYMAN PLUMBER REGISTRATION
409.1 JOURNEYMAN PLUMBER REGISTRATION QUALIFICATIONS
174 409.2 EXPERIENCE
409.3 REGISTRATION NEED NOT BE RENEWED
409.4 REGISTRATION CARD
ARTICLE 410 MASTER FIRE SUPPRESSION PIPING CONTRACTOR LICENSE
410.1 MASTER FIRE SUPPRESSION PIPING CONTRACTOR LICENSE REQUIRED
410.2 SEAL
410.3 CLASSIFICATION
410.4 ADDITIONAL QUALIFICATIONS
175 410.5 CERTIFICATE OF COMPETENCE, AND LICENSE AND SEAL
176 410.6 SURRENDER OF LICENSE AND SEAL
410.7 MASTER FIRE SUPPRESSION PIPING CONTRACTOR BUSINESS REQUIRED
177 410.8 FITNESS TO PERFORM WORK
ARTICLE 411 JOURNEYMAN FIRE SUPPRESSION PIPING INSTALLER REGISTRATION
411.1 JOURNEYMAN FIRE SUPPRESSION PIPING INSTALLER REGISTRATION QUALIFICATIONS
411.2 EXPERIENCE
411.3 REGISTRATION NEED NOT BE RENEWED
411.4 REGISTRATION CARD
ARTICLE 412 OIL-BURNING EQUIPMENT INSTALLER LICENSE
412.1 OIL-BURNING EQUIPMENT INSTALLER LICENSE REQUIRED
412.2 USE
412.3 QUALIFICATIONS
178 412.4 FITNESS TO PERFORM WORK
412.5 OIL-BURNING EQUIPMENT INSTALLER PLACE OF BUSINESS
412.6 SEAL
ARTICLE 413 HIGH-PRESSURE BOILER OPERATING ENGINEER LICENSE
413.1 HIGH-PRESSURE BOILER OPERATING ENGINEER LICENSE REQUIRED
413.2 QUALIFICATIONS
179 413.3 FITNESS TO PERFORM WORK
ARTICLE 414 RESERVED
ARTICLE 415 SIGN HANGER LICENSE
415.1 SIGN HANGER LICENSE REQUIRED
415.2 EXEMPTIONS
415.3 CLASSIFICATION
415.4 ADDITIONAL QUALIFICATIONS
415.5 ADDITIONAL REQUIREMENTS
415.6 FITNESS TO PERFORM WORK
180 ARTICLE 416 FILING REPRESENTATIVE REGISTRATION
416.1 FILING REPRESENTATIVE REGISTRATION
416.2 EXEMPTIONS
416.3 RULES
ARTICLE 417 RESERVED
ARTICLE 418 GENERAL CONTRACTOR REGISTRATION
418.1 REQUIREMENT OF REGISTRATION
418.2 UNLAWFUL USE OF GENERAL CONTRACTOR TITLE
418.3 APPLICATION REQUIREMENTS
181 418.4 WARRANTIES
418.5 DUTIES AND RESPONSIBILITIES
ARTICLE 419 SEIZURE AND FORFEITURE
419.1 GENERAL
419.2 DEFINITIONS
419.3 SEIZURE PROCEDURE
182 419.4 ABANDONED PROPERTY
419.5 COMBINED HEARINGS
419.6 SEPARATE HEARINGS
419.7 FORFEITURE PROCEDURE
183 ARTICLE 420 REQUIREMENT OF SAFETY REGISTRATION NUMBER
420.1 REQUIREMENT OF APPLICATION FOR SAFETY REGISTRATION NUMBER
420.2 APPLICATION REQUIREMENTS
420.3 DUTIES AND RESPONSIBILITIES
184 420.4 SUBMJISSION OF PLAN TO REDUCE RATE OF IMMEDIATELY HAZARDOUS VIOLATIONS
420.5 SUBMISSION OF A REPORT TO THE CITY COUNCIL
420.6 EXPIRATION OF SAFETY REGISTRATION NUMBER
420.7 UNLAWFUL USE OF SAFETY REGISTRATION NUMBER
ARTICLE 421 ELEVATOR AGENCY DIRECTOR LICENSE
421.1 ELEVATOR AGENCY DIRECTOR LICENSE REQUIRED
421.2 QUALIFICATIONS
421.3 RESTRICTION
421.4 PLACE OF BUSINESS
ARTICLE 422 ELEVATOR AGENCY INSPECTOR LICENSE
422.1 ELEVATOR AGENCY INSPECTOR LICENSE REQUIRED
422.2 QUALIFICATIONS
185 422.3 RESTRICTION
ARTICLE 423 QUALIFICATION FOR GAS WORK
423.1 QUALIFICATION REQUIRED
423.2 APPLICATIONS FOR GAS WORK QUALIFICATION
423.3 APPLICATIONS FOR LIMITED GAS WORK QUALIFICATION
423.4 EXPIRATION
ARTICLE 424 LIFT DIRECTOR REGISTRATION
424.1 LIFT DIRECTOR REQUIRED
186 424.2 REGISTRATION REQUIRED
424.3 QUALIFICATIONS
ARTICLE 425 ELEVATOR AGENCY TECHNICIAN LICENSE
425.1 ELEVATOR AGENCY TECHNICIAN LICENSE REQUIRED
425.2 RESTRICTED ELEVATOR AGENCY TECHNICIAN LICENSE
425.3 QUALIFICATIONS
187 425.4 EXEMPTIONS
425.5 TERM OF LICENSE
ARTICLE 426 ELEVATOR AGENCY HELPER
426.1 QUALIFICATIONS
ARTICLE 427 PERMITS
427.1 APPLICATIONS AND PERMITS
427.2 LICENSING AND PERMITTING EXEMPTIONS
427.3 LICENSE RENEWAL
427.4 RENEWAL FEES
427.5 RECORDKEEPING
188 ARTICLE 428 CONSTRUCTION SUPERINTENDENT LICENSE
428.1 LICENSE REQUIRED
428.2 QUALIFICATIONS
428.3 PREVIOUS REGISTRANTS
428.4 FITNESS TO PERFORM WORK
190 CHAPTER 5 MISCELLANEOUS PROVISIONS
ARTICLE 501 MAINTENANCE PERMIT FOR OUTDOOR SIGNS
501.1 PERMIT REQUIRED
501.2 APPLICATION
501.3 PERMIT EXPIRATION
501.4 CIVIL PENALTIES
501.5 CONSTRUCTION
501.6 EXEMPTION
191 ARTICLE 502 OUTDOOR ADVERTISING COMPANIES
502.1 DEFINITIONS
502.2 REGISTRATION OF OUTDOOR ADVERTISING COMPANIES
502.3 REVOCATION OR SUSPENSION OF REGISTRATION
192 502.4 REPORTING REQUIREMENT
502.5 DISPLAY OF NAME OF REGISTRATION NUMBER OF OUTDOOR ADVERTISING COMPANY
502.6 CRIMINAL AND CIVIL PENALTIES
193 502.7 SIGNS UNDER CONTROL OF UNREGISTERED OUTDOOR ADVERTISING COMPANY ARE PUBLIC NUISANCE
502.8 FRANCHISE OR CONCESSION DISQUALIFICATION
502.9 INVESTIGATIONS
ARTICLE 503 NUISANCE ABATEMENT FOR ILLEGAL SIGNS
503.1 GENERAL
503.2 NOTICE
194 503.3 HEARING
503.4 POSTING OF ORDER
503.5 ENFORCEMENT OF ORDER
503.6 RESCISSION OF ORDER
503.7 COSTS
503.8 LIEN
503.9 STORAGE AND DISPOSAL
503.10 DEFINITIONS
503.11 REVIEW OF ORDER
ARTICLE 504 BICYCLE ACCESS TO BUILDINGS
504.1 BICYCLE ACCESS TO CERTAIN OFFICE BUILDINGS
196 504.2 CONSTRUCTION
504.3 FOLDABLE BICYCLE ACCESS
504.4 EMERGENCIES
504.5 BICYCLE ACCESS TO RESIDENTIAL BUILDINGS
504.6 FOLDABLE BICYCLES ON PASSENGER ELEVATORS IN RESIDENTIAL BUILDINGS
197 ARTICLE 505 CERTIFICATION OF NO HARASSMENT PILOT PROGRAM
505.1 GENERAL
505.2 DEFINITIONS
505.3 COVERED CATEGORIES OF WORK
505.4 REQUIRED SUBMITTAL DOCUMENTS
198 505.5 PROCESS
505.6 TIME PERIOD FOR APPROVAL OR REJECTION OF CONSTRUCTION DOCUMENTS
505.7 CERTIFICATE OF OCCUPANCY
505.8 REQUEST FOR STOP-WORK OR RESCISSION
ARTICLE 506 EMISSION PROFILE OF BUILDINGS
506.1 PROHIBITED EMISSIONS IN NEW BUILDINGS
200 ICC DIGITAL CODES PREMIUM
201 ICC ASSESSMENT CENTER
202 ICC LEARNING CENTER
203 ICC EVALUATION SERVICE
]]>
NY NYC FuelGasCode 2022 1stptg ?u=/product/publishers/ny/ny-nyc-fuelgascode-2022-1stptg/ Sun, 20 Oct 2024 06:12:39 +0000 New York City Fuel Gas Code
Published By Publication Date Number of Pages
NY 2022
]]>
The is a fully integrated custom code based on the 2015 International Fuel Gas Code. Effective date: November 7, 2022.

PDF Catalog

PDF Pages PDF Title
1 2022 NEW YORK CITY FUEL GAS CODE
2 2022 NEW YORK CITY FUEL GAS CODE TITLE PAGE
3 COPYRIGHT
4 DEDICATION
6 NEW YORK CITY CONSTRUCTION CODES PREFACE
8 ACKNOWLEDGEMENTS
16 TITLE 28 OF THE NEW YORK CITY ADMINISTRATIVE CODE INCLUDING THE NEW YORK CITY CONSTRUCTION CODES
18 TITLE 28 NEW YORK CITY CONSTRUCTION CODES
20 TABLE OF CONTENTS
22 CHAPTER 1 ADMINISTRATION
SECTION FGC 101 GENERAL
SECTION FGC 102 APPLICABILITY
23 SECTION FGC 103 DEPARTMENT OF BUILDINGS
SECTION FGC 104 DUTIES AND POWERS OF THE COMMISSIONER OF BUILDINGS
24 SECTION FGC 105 APPROVALS
SECTION FGC 106 PERMITS
SECTION FGC 107 CONSTRUCTION DOCUMENTS
25 SECTION FGC 108 INSPECTIONS AND TESTING
26 SECTION FGC 109 VIOLATIONS
28 CHAPTER 2 DEFINITIONS
SECTION FGC 201 GENERAL
29 SECTION FGC 202 GENERAL DEFINITIONS
38 CHAPTER 3 GENERAL REGULATIONS
SECTION FGC 301 GENERAL
39 SECTION FGC 302 STRUCTURAL SAFETY
40 SECTION FGC 303 APPLIANCE LOCATION
41 TABLE 303.3.1.7 PTAC AND PTHP VENT TERMINATION CLEARANCE TO AIR OPENINGS
SECTION FGC 304 COMBUSTION, VENTILATION AND DILUTION AIR
42 EQUATION 3-1
EQUATION 3-2
FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING
43 FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC
FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS
44 FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS
45 SECTION FGC 305 INSTALLATION
46 SECTION FGC 306 ACCESS AND SERVICE SPACE
48 SECTION FGC 307 CONDENSATE DISPOSAL
SECTION FGC 308 CLEARANCE REDUCTION
49 TABLE 308.2a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
50 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
51 FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
52 SECTION FGC 309 ELECTRICAL
SECTION FGC 310 ELECTRICAL BONDING
54 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION FGC 401 GENERAL
SECTION FGC 402 PIPE SIZING
55 EQUATION 4-1
EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AT STANDARD CONDITIONS
56 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
57 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
58 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
59 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
60 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
61 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
62 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
63 SECTION FGC 403 PIPING MATERIALS
64 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
SECTION FGC 404 PIPING SYSTEM INSTALLATION
68 SECTION FGC 405 PIPING BENDS AND CHANGES IN DIRECTION
SECTION FGC 406 INSPECTION, TESTING AND PURGING
71 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
72 SECTION FGC 407 PIPING SUPPORT
SECTION FGC 408 DRIPS AND SLOPED PIPING
FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
SECTION FGC 409 SHUTOFF VALVES
73 TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
SECTION FGC 410 FLOW CONTROLS
74 SECTION FGC 411 APPLIANCE AND MANUFACTURED HOME CONNECTIONS
75 SECTION FGC 412 LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
SECTION FGC 413 COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
76 SECTION FGC 414 RESERVED
SECTION FGC 415 PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION FGC 416 OVERPRESSURE PROTECTION DEVICES
78 CHAPTER 5 CHIMNEYS AND VENTS
SECTION FGC 501 GENERAL
81 SECTION FGC 502 VENTS
82 SECTION FGC 503 VENTING OF APPLIANCES
83 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
85 EQUATION 5-1
FIGURE 503.5.4 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT APPLIANCES
87 EQUATION 5-2
88 FIGURE 503.6.4 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
91 TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
92 FIGURE 503.10.4.1 OPPOSING OPENINGS IN CHIMNEY
TABLE 503.10.5a CLEARANCES FOR CONNECTORS
94 SECTION FGC 504 SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
95 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
96 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
97 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
98 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
99 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
100 TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
101 TABLE 504.2(3) MASONRY CHIMNEY
102 TABLE 504.2(3)—continued MASONRY CHIMNEY
103 TABLE 504.2(4) MASONRY CHIMNEY
104 TABLE 504.2(4)—continued MASONRY CHIMNEY
105 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
106 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
108 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
109 TABLE 504.3(1)—continued TYPE B DOUBLE-WALL VENT
110 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
111 TABLE 504.3(3) MASONRY CHIMNEY
112 TABLE 504.3(4) MASONRY CHIMNEY
113 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
114 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b)—continued EXTERIOR MASONRY CHIMNEY
115 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b)—continued EXTERIOR MASONRY CHIMNEY
116 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
117 FIGURE 504.3.4 USE OF A MANIFOLD COMMON VENT CONNECTOR
118 SECTION FGC 505 DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION FGC 506 FACTORY-BUILT CHIMNEYS
119 SECTION FGC 507 CHANGES IN APPLIANCE FUELS
SECTION FGC 508 EXHAUST GASES FROM INTERNAL COMBUSTION ENGINES AND TURBINES
120 CHAPTER 6 SPECIFIC APPLIANCES
SECTION FGC 601 GENERAL
SECTION FGC 602 DECORATIVE GAS-FIRED APPLIANCES FOR INSTALLLATION IN FIREPLACES
SECTION FGC 603 LOG LIGHTERS
SECTION FGC 604 VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION FGC 605 VENTED GAS FIREPLACE HEATERS
SECTION FGC 606 RESERVED
SECTION FGC 607 COMMERCIAL-INDUSTRIAL INCINERATORS AND CREMATORIES
121 SECTION FGC 608 VENTED WALL FURNACES
SECTION FGC 609 FLOOR FURNACES
122 SECTION FGC 610 DUCT FURNACES
SECTION FGC 611 NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION FGC 612 RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
123 SECTION FGC 613 CLOTHES DRYERS
SECTION FGC 614 CLOTHES DRYER EXHAUST
SECTION FGC 615 SAUNA HEATERS
124 SECTION FGC 616 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION FGC 617 POOL AND SPA HEATERS
SECTION FGC 618 FORCED-AIR WARM-AIR FURNACES
125 SECTION FGC 619 CONVERSION BURNERS
SECTION FGC 620 UNIT HEATERS
SECTION FGC 621 UNVENTED ROOM HEATERS
SECTION FGC 622 VENTED ROOM HEATERS
SECTION FGC 623 COOKING APPLIANCES
126 SECTION FGC 624 WATER HEATERS
SECTION FGC 625 REFRIGERATORS
127 SECTION FGC 626 GAS-FIRED TOILETS
SECTION FGC 627 AIR CONDITIONING APPLIANCES
SECTION FGC 628 ILLUMINATING APPLIANCES
128 SECTION FGC 629 CERAMIC KILNS
SECTION FGC 630 INFRARED RADIANT HEATERS
SECTION FGC 631 BOILERS
SECTION FGC 632 EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION FGC 633 STATIONARY FUEL CELL POWER SYSTEMS
SECTION FGC 634 CHIMNEY DAMPER OPENING AREA
SECTION FGC 635 GASEOUS HYDROGEN SYSTEMS
129 TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION FGC 636 OUTDOOR DECORATIVE APPLIANCES
130 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION FGC 701 GENERAL
SECTION FGC 702 RESERVED
SECTION FGC 703 GENERAL REQUIREMENTS
SECTION FGC 704 RESERVED
SECTION FGC 705 RESERVED
SECTION FGC 706 LOCATION OF GASEOUS HYDROGEN SYSTEMS
132 CHAPTER 8 REFERENCED STANDARDS
SECTION FGC 801 GENERAL
SECTION FGC 802 STANDARDS
ANSI
133 ASME
ASNT
134 ASTM
CAN/ULC
CSA
MSS
135 NFPA
UL
136 APPENDIX A RESERVED
138 APPENDIX B RESERVED
140 APPENDIX C RESERVED
142 APPENDIX D RESERVED
144 APPENDIX E METERS AND GAS SERVICE PIPING
E.1 GENERAL
E.2 GAS REGULATOR AND GAS REGULATOR VENT OUTLETS
E.3 GAS METER LOCATION
145 E.4 GAS METER ROOM VENTILATION
E.5 GAS SERVICE PIPING CONNECTIONS
146 E.6 OUTSIDE GAS CUT-OFF
148 APPENDIX F RESERVED
150 APPENDIX G HIGH PRESSURE NATURAL GAS INSTALLATIONS
G.1 GENERAL
G.2 CONSTRUCTION REQUIREMENTS
G.3 HIGH HAZARD
151 G.4 GAS METER ROOM
G.5 PIPING REQUIREMENTS
G.6 SPECIAL INSPECTION REQUIRED
G.7 CLEANING AND PURGING PROCEDURES
152 INDEX RESERVED
154 ICC DIGITAL CODES PREMIUM
155 ICC ASSESSMENT CENTER
156 ICC LEARNING CENTER
157 ICC EVALUATION SERVICE
]]>
NY NYC InclusiveDesignGuidelines 2ndEdition 2015 ?u=/product/publishers/ny/ny-nyc-inclusivedesignguidelines-2ndedition-2015/ Sat, 19 Oct 2024 13:26:49 +0000 Inclusive Design Guidelines: New York City 2nd Edition
Published By Publication Date Number of Pages
NY 2015 391
]]>
The Inclusive Design Guidelines, New York City, Second Edition confirms that it is a living document and that Inclusive Design is dynamic. The premise of the book holds true: “The IDG is voluntary technical guidance helping designers produce multisensory enhanced environments that accommodate a wide range of physical and mental abilities for people of all ages.” Adoption of the ICC A117.1 standard has proven to be correct because of its relevant content, structure, numbering system and harmonization with the New York City Building Code, the 2010 ADA Standards, and other legal requirements. Expansion and refinements of this edition comprise 25% new content; 15% updates, and two hundred forty (240) additional figures.

PDF Catalog

PDF Pages PDF Title
1 INCLUSIVE DESIGN GUIDELINES – NEW YORK CITY SECOND EDITION
2 INCLUSIVE DESIGN GUIDELINES – NEW YORK CITY SECOND EDITION TITLE PAGE
3 COPYRIGHT
6 THE CITY OF NEW YORK OFFICE OF THE MAYOR NEW YORK, NY 10007 GREETINGS
8 THE CITY OF NEW YORK OFFICE OF THE MAYOR NEW YORK, NY 10007 DEAR FRIENDS
THE CITY OF NEW YORK OFFICE OF MAYOR CONTACT LIST
10 ACKNOWLEDGEMENTS
12 FOREWORD
14 PREFACE
16 CONTENTS
20 LIST OF FIGURES
30 CHAPTER 1: APPLICATION AND ADMINISTRATION
100 INTRODUCTION
32 101 PURPOSE
102 HUMAN FACTOR PROVISIONS
103 COMPLIANCE ALTERNATIVES
104 CONVENTIONS
FIGURE 104.2 GRAPHIC CONVENTION FOR FIGURES
33 FIGURE 104.7 MARGINAL MARKINGS
105 REFERENCED STANDARDS AND RESOURCES
35 106 DEFINITIONS
40 CHAPTER 2: SCOPING
200 INTRODUCTION
42 201 GENERAL
202 DWELLING AND SLEEPING UNITS
203 ADMINISTRATION/DISCLAIMER
44 CHAPTER 3: BUILDING BLOCKS
300 INTRODUCTION
46 301 GENERAL
302 FLOOR SURFACES
FIGURE 302.2.2 EXAMPLES OF MATERIAL TRANSITIONS
47 FIGURE 302.4 JOINTS
49 FIGURE 302.8 SURFACE DISTORTION
FIGURE 302.9 EDGES
50 FIGURE 302.10 VISUAL CONTRAST
303 CHNAGES IN LEVEL
FIGURE 303.2 VERTICAL CHANGES IN LEVEL
51 FIGURE 303.3 BEVELED CHANGES IN LEVEL
FIGURE 303.7 MULTIPLE CHANGES IN LEVEL
304 TURNING SPACE
53 FIGURE 304.3.1 TIER I TURNING SPACE
FIGURE 304.3.2 TIER II TURNING SPACE
FIGURE 304.3.3 TIER III TURNING SPACE
305 CLEAR FLOOR SPACE
54 FIGURE 305.3.1 TIER I CLEAR FLOOR SPACE
FIGURE 305.3.2 TIER II CLEAR FLOOR SPACE
55 FIGURE 305.3.3 TIER III CLEAR FLOOR SPACE
FIGURE 305.7.1.1 TIER I PARALLEL APPROACH
FIGURE 305.7.1.2 TIER II PARALLEL APPROACH
56 FIGURE 305.7.1.3 TIER III PARALLEL APPROACH
FIGURE 305.7.2.1 TIER I FORWARD APPROACH
FIGURE 305.7.2.2 TIER II FORWARD APPROACH
57 FIGURE 305.7.2.3 TIER III FORWARD APPROACH
306 KNEE AND TOE CLEARANCES
58 FIGURE 306.2.1 TIER 1 ADULT TOE CLEARANCE
59 FIGURE 306.2.2 TIER II CHILDREN’S TOE CLEARANCE
60 FIGURE 306.3.1.1 TIER I ADULT KNEE CLEARANCE
FIGURE 306.3.2 TIER II CHILDREN’S KNEE CLEARANCE
61 FIGURE 306.3.3 TIER III INSTITUTIONAL KNEE CLEARANCE
307 PROTRUDING OBJECTS
62 FIGURE 307.2 LIMITS OF PROTRUDING OBJECTS
63 FIGURE 307.3 POST-MOUNTED PROTRUDING OBJECTS
FIGURE 307.4 REDUCED VERTICAL CLEARANCE
64 308 REACH RANGES
FIGURE 308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 308.2.2 OBSTRUCTED HIGH FORWARD REACH
65 FIGURE 308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 308.3.2 OBSTRUCTED HIGH SIDE REACH
66 TABLE 308.4 CHILDREN’S REACH RANGES
FIGURE 308.5 SUPPLEMENTAL ADULT STANDING REACH RANGE
309 OPERABLE PARTS
67 FIGURE 309.3.1 COMFORT SEATED REACH ZONE
FIGURE 309.3.2 STANDING COMFORT REACH ZONE
FIGURE 309.3.3 STANDING/SEATED COMFORT ZONES OVERLAP
70 310 EYE LEVELS
71 FIGURE 310.1 ADULT STANDING
FIGURE 310.2 ADULT SITTING
FIGURE 310.3 CHILD STANDING & PEOPLE OF SHORT STATURE STANDING
FIGURE 310.4 CHILD SITTING & PEOPLE OF SHORT STATURE STANDING
72 FIGURE 310.5 ADULT SITTING IN MOBILITY DEVICE
FIGURE 310.6 CHILD SITTING IN MOBILITY DEVICE
FIGURE 310.7.1 TIER I ADULT HORIZONTAL EYE POSITION FOR A FORWARD APPROACH
FIGURE 310.7.2 TIER II CHILDREN’S HORIZONTAL EYE POSITION FOR A FORWARD APPROACH
73 FIGURE 310.7.3 TIER III INSTITUTIONAL HORIZONTAL EYE POSITION FOR A FORWARD APPROACH
FIGURE 310.8 HORIZONTAL EYE POSITION FOR A PARALLEL APPROACH
311 LIGHTING
74 CHAPTER 4: ROUTES
400 INTRODUCTION
76 401 GENERAL
402 ROUTES
78 FIGURE 402.4.3.1 EXERCISE STATION EXAMPLE LEG PRESS
FIGURE 402.4.4 ROUTE SLOPE AFFECTING REST AREA
80 FIGURE 402.4.10 EMBEDDED LED LIGHTING / SENSORS
81 403 WALKING SURFACES
82 FIGURE 403.3 WALKING SURFACE SLOPE
FIGURE 403.5.1.1 TIER I PRIMARY ROUTE CLEAR WIDTH
83 FIGURE 403.5.1.1.1 TIER I SECONDARY AND TERTIARY ROUTE CLEAR WIDTH
FIGURE 403.5.1.2 TIER II PRIMARY ROUTE CLEAR WIDTH
FIGURE 403.5.1.2.1 TIER II SECONDARY AND TERTIARY ROUTE CLEAR WIDTH
84 FIGURE 403.5.1.3 TIER III PRIMARY ROUTE CLEAR WIDTH
FIGURE 403.5.1.3.1 TIER III SECONDARY AND TERTIARY ROUTES CLEAR WIDTH
85 FIGURE 403.5.2.1 TIER I CLEAR WIDTH AT 180 DEGREE TURN
FIGURE 403.5.2.1.1 TIER I CLEAR WIDTH AT 90 DEGREE TURN
86 FIGURE 403.5.2.2 TIER II CLEAR WIDTH AT 180 DEGREE TURN
FIGURE 403.5.2.2.1 TIER II CLEAR WIDTH AT 90 DEGREE TURN
87 FIGURE 403.5.2.3 TIER III CLEAR WIDTH AT 180 DEGREE TURN
FIGURE 403.5.2.3.1 TIER III CLEAR WIDTH AT 90 DEGREE TURN
88 FIGURE 403.5.3 PASSING SPACES FOR SECONDARY AND TERTIARY ROUTES
FIGURE 403.5.4.1 TIER I CORRIDOR DEAD END
FIGURE 403.5.4.2 TIER II CORRIDOR DEAD END
89 FIGURE 403.5.4.3 TIER III CORRIDOR DEAD END
90 FIGURE 403.11.1 ANGLE OF INCLINATION OF MOVING WALKWAYS
404 DOORS, DOORWAYS AND GATES
91 FIGURE 404.2.1 DOUBLE-LEAF DOORS, DOORWAYS AND GATES
92 FIGURE 404.2.2 CLEAR WIDTH OF DOORWAYS
FIGURE 404.2.2.1.1 SWING CLEAR OFFSET HINGE
93 FIGURE 404.2.3 MANEUVERING CLEARANCES AT DOORWAYS
94 FIGURE 404.2.5 TWO DOORS IN A SERIES
FIGURE 404.2.6 DOOR HARDWARE
97 FIGURE 404.3.5.1 WALL SWITCH CONTROL LOCATION
405 RAMPS
98 FIGURE 405.7.3 RAMP ENTRY LANDINGS
99 FIGURE 405.7.4 CHANGE IN DIRECTION
FIGURE 405.7.4.1 INTERMEDIATE LANDINGS
100 FIGURE 405.7.4.2 REST AREA
FIGURE 405.7.5 DOORWAY LANDING
101 FIGURE 405.9.1 EXTENDED FLOOR SURFACE
FIGURE 405.9.2 RAMP EDGE PROTECTION
104 FIGURE 405.16 CONVERTIBLE WALKWAYS
105 FIGURE 405.18 SLOPED WALK / BLEACHER SEATING EXAMPLE
106 406 CURB RAMPS
107 FIGURE 406.2 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
108 FIGURE 406.3 SIDES OF CURB RAMPS
109 FIGURE 406.9 SIDEWALK EXTENSION EXAMPLE
110 FIGURE 406.10 DIAGONAL CURB RAMPS
111 FIGURE 406.11 ISLANDS
112 FIGURE 406.12 RAISED MARKED CROSSING
114 FIGURE 406.15 ACCESSIBLE PEDESTRIAN SIGNAL (APS) PUSH BUTTON UNIT EXAMPLE
116 FIGURE 406.16.4 EMBEDDED LED LIGHTING / SENSORS EXAMPLE
118 407 ELEVATORS
119 FIGURE 407.2 ELEVATOR LANDING CLEAR FLOOR SPACE
FIGURE 407.2.1.1 HEIGHT OF ELEVATOR CALL BUTTONS
120 FIGURE 407.2.1.7 DESTINATION-ORIENTED ELEVATOR CONTROL BUTTONS
122 FIGURE 407.2.2.2 ELEVATOR VISIBLE SIGNALS
124 FIGURE 407.4.1 INSIDE DIMENSION OF ELEVATOR CARS
FIGURE 407.4.6.1 LOCATION
125 FIGURE 407.4.6.2 ELEVATOR CAR CONTROL BUTTONS
127 FIGURE 407.4.7.1.3 CONTROL BUTTON IDENTIFICATION
129 408 LIMITED-USE / LIMITED-APPLICATION ELEVATORS (LULA)
130 FIGURE 408.4.1 INSIDE DIMENSIONS OF LIMTED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CARS
409 PRIVATE RESIDENCE ELEVATORS
131 FIGURE 409.4.6.3 LOCATION OF CONTROLS IN PRIVATE RESIDENCE ELEVATORS
132 410 PLATFORM LIFTS
133 FIGURE 410.1.1.2 ALIGNED CLOSETS FOR VERTICAL PLATFORM LIFT CONVERSION
134 FIGURE 410.1.2 INCLINED PLATFORM LIFT
135 FIGURE 410.2.1 PLATFORM LIFT DOORS AND GATES
137 411 PORTABLE PLATFORM LIFTS
412 MOVING WALKWAYS
138 FIGURE 412 MOVING WALKWAY
140 CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS
500 INTRODUCTION
142 501 GENERAL
502 PARKING SPACES AND FACILITIES
FIGURE 502.1 INCLUSIVE PARKING SPACE
143 FIGURE 502.1.3 INTERNATIONAL SYMBOL UPDATED
147 FIGURE 502.3.4 FLOOR, WALL/CEILING STORAGE
FIGURE 502.3.5 STANDARD BICYCLE SPACE DIMENSIONS
148 FIGURE 502.3.6.1 SCOOTER SPACE DIMENSIONS
FIGURE 502.3.6.2 TRICYCLE SPACE DIMENSIONS
FIGURE 502.3.6.3 HANDCYCLE SPACE DIMENSIONS
FIGURE 502.3.6.4 TANDEM BICYCLE SPACE DIMENSIONS
150 503 PASSENGER LOADING ZONES
151 FIGURE 503 PASSENGER LOADING ZONE
152 504 STAIRWAYS
153 FIGURE 504.2 TREAD DEPTH AND RISER HEIGHTS
154 FIGURE 504.5 TREAD AND RISER PROFILES
156 505 HANDRAILS
157 FIGURE 505.4 DUAL HANDRAIL HEIGHTS
158 FIGURE 505.5 HANDRAIL CLEARANCE
159 FIGURE 505.7 HANDRAIL CROSS SECTIONS
160 FIGURE 505.10.1 TOP AND BOTTOM HANDRAIL EXTENSIONS AT RAMPS
FIGURE 505.10.2 TOP HANDRAIL EXTENSIONS AT STAIR
FIGURE 505.10.3 BOTTOM HANDRAIL EXTENSIONS AT STAIR
161 506 WINDOWS
164 CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES
600 INTRODUCTION
166 601 GENERAL
602 DRINKING FOUNTAINS
167 FIGURE 602.2.3 CLEAR FLOOR SPACE CHILDREN SEATED FORWARD APPROACH
168 FIGURE 602.8 BOTTLE FILLERS
FIGURE 602.9 COMBINED UNITS
FIGURE 602.9.1 EXAMPLE OF PORTABLE MULTIPLE DRINKING FOUNTAIN UNIT
169 603 TOILET AND BATHING ROOMS
170 FIGURE 603.1.3.1 EXAMPLE OF DOORLES ENTRY
171 FIGURE 603.1.4.1 MANUALLY OPERATED ENTRY DOOR CONTAMINATION REDUCTION
173 604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 604.2.1 ADULT WATER CLOSET LOCATION
174 FIGURE 604.2.2 AMBULATORY WATER CLOSET
FIGURE 604.2.3 CHILDREN’S WATER CLOSET
175 FIGURE 604.3 CLEARANCE FOR WATER CLOSET IN ADULT AND SINGLE OCCUPANT RESTROOM/BATHROOM
176 FIGURE 604.4.1 ADULT WATER CLOSET SEAT HEIGHT
177 FIGURE 604.4.2 CHILD WATER CLOSET SEAT HEIGHTS
FIGURE 604.4.3 PEOPLE OF SHORT STATURE WATER CLOSET SEAT HEIGHT
178 FIGURE 604.5.3 SUPPLEMENTAL SWING-UP GRAB BAR
180 FIGURE 604.8 ADULT COMPARTMENT
181 FIGURE 604.8.3 SELF CLOSING DOOR
182 FIGURE 604.9 ADULT AMBULATORY COMPARTMENT
184 FIGURE 604.10 SUPPLEMENTAL CHILDREN’S AND PEOPLE OF SHORT STATURE INCLUSIVE COMPARTMENT
187 605 URINALS
FIGURE 605.5 URINAL PRIVACY PARTITION
188 606 LAVATORIES AND SINKS
189 FIGURE 606.3 HEIGHT OF LAVATORIES AND SINKS
190 607 BATHTUBS
FIGURE 607.1.2 CLEARANCE FOR BATHTUBS
191 FIGURE 607.1.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
192 FIGURE 607.1.4.2 GRAB BARS FOR BATHTUBS WITHOUT PERMANENT SEATS
FIGURE 607.1.5 LOCATION OF BATHTUB CONTROLS
193 FIGURE 607.1.9 BATHTUB WALK-THROUGH CUT-OUT DOOR
FIGURE 607.1.14 RECESSED STORAGE NICHE
194 FIGURE 607.2.2 TRANSFER WALK-IN BATHTUB COMPARTMENT SIZE AND CLEARANCE
FIGURE 607.2.4 GRAB BARS & CONTROL LOCATION
196 608 SHOWERS, MULTIPURPOSE BATHING COMPARTMENTS AND WET ROOMS
FIGURE 608.1.2.1 TRANSFER-TYPE SHOWER COMPARTMENT SIZE & CLEARANCE
FIGURE 608.1.2.2 STANDARD ROLL-IN-TYPE SHOWER COMPARTMENTS SIZE & CLEARANCE
197 FIGURE 608.1.2.3 ALTERNATE ROLL-IN-TYPE SHOWER COMPARTMENT SIZE & CLEARANCE
FIGURE 608.1.3.1 GRAB BARS IN TRANSFER-TYPE SHOWERS
198 FIGURE 608.1.3.2 GRAB BARS IN STANDARD ROLL-IN-TYPE SHOWERS
FIGURE 608.1.3.3 GRAB BARS IN ALTERNATE ROLL-IN-TYPE SHOWERS
FIGURE 608.1.4.1 TRANSFER-TYPE SHOWER CONTROL AND HANDSHOWER LOCATION
199 FIGURE 608.1.4.2 STANDARD ROLL-IN SHOWER CONTROL AND HANDSHOWER LOCATION
FIGURE 608.1.4.3 ALTERNATE ROLL-IN TYPE SHOWER CONTROL AND HANDSHOWER LOCATION
201 FIGURE 608.2.2 MULTIPURPOSE BATHING COMPARTMENT SIZE AND CLEARANCE
205 FIGURE 608.2.2.4 MULTIPURPOSE BATHING COMPARTMENT EXAMPLE VARIATIONS
FIGURE 608.2.5 CONTROLS AND HAND SHOWER LOCATIONS
207 FIGURE 608.3.2 WET ROOM SHOWER AREA SIZE AND CLEARANCE
208 FIGURE 608.3.4 CONTROL AND HAND SHOWER LOCATION
209 609 GRAB BARS
FIGURE 609.2 GRAB BAR CROSS SECTIONS
210 FIGURE 609.3 SPACING OF GRAB BARS
610 SHOWER SEATS
211 FIGURE 610.4 SHOWER SEAT CLEARANCES
611 WASHINGTON MACHINES AND CLOTHES DRYERS
212 FIGURE 611.2 CLEAR FLOOR SPACE
FIGURE 611.4 HEIGHT OF LAUNDRY EQUIPMENT
FIGURE 611.5 SLOPED FRONT FACE
213 612 SAUNAS AND STEAM ROOMS
FIGURE 612.1.2 STANDARD SAUNA UNIT SIZE & CLEARANCE
215 FIGURE 612.2.2.1 TRANSFER SAUNA AND STEAM COMPARTMENT SIZE & CLEARANCE
216 FIGURE 612.2.4 CONTROLS AND HAND-HELD SHOWER LOCATIONS IN TRANSFER TYPE COMPARTMENTS
218 CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES
700 INTRODUCTION
220 701 GENERAL
702 ALARMS
FIGURE 702.2.1 HELP BUTTON EXAMPLE
221 FIGURE 702.2.4 UPPER BUTTON LOCATION
FIGURE 702.2.5 LOWER BUTTON LOCATION
703 SIGNS
222 TABLE 703.2.4 CHARACTER HEIGHT
224 FIGURE 703.3.5 CHARACTER HEIGHT
225 FIGURE 703.3.10 HEIGHT OF TACTILE CHARACTERS ABOVE FLOOR OR GROUND
226 FIGURE 703.3.11 LOCATION OF TACTILE SIGNAGE AT DOORS
228 FIGURE 703.4.1 BRAILLE ALPHABET
229 FIGURE 703.4.3 DIMENSIONS
FIGURE 703.4.4 POSITION OF BRAILLE
230 TABLE 703.4.3 BRAILLE DIMENSIONS
231 FIGURE 703.4.5.8 BRAILLE SENTENCE EXAMPLE
FIGURE 703.5.2 PICTOGRAM FIELD
232 FIGURE 703.5.5 PICTOGRAM EXAMPLES
FIGURE 703.5.6 PICTOGRAM SEQUENCE EXAMPLE (TAKING MEDICATION)
233 FIGURE 703.6.3.1 ACTIVE SYMBOL OF ACCESSIBILITY
FIGURE 703.6.3.2 INTERNATIONAL TTY SYMBOL
FIGURE 703.6.3.3 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
234 FIGURE 703.6.3.4 VOLUME-CONTROLLED TELEPHONE
FIGURE 703.6.3.5 AUDIO DESCRIPTION
FIGURE 703.6.3.6 BRAILLE SYMBOL
235 FIGURE 703.6.3.7 CLOSED CAPTIONING (CC)
FIGURE 703.6.3.8 SIGN LANGUAGE INTERPRETATION
FIGURE 703.6.3.8.1 COMMUNICATION ACCESS REALTIME TRANSLATION (C.A.R.T.)
236 FIGURE 703.6.3.8 AMERICAN SIGN LANGUAGE ALPHABET
237 FIGURE 703.6.3.9 LARGE PRINT (18 PT. OR LARGER)
FIGURE 703.6.3.10 (OTHER THEN PRINT OR BRAILLE) FOR INDIVIDUALS WHO ARE BLIND OR HAVE LOW VISION
FIGURE 703.6.3.11 OPEN CAPTIONING (OC)
FIGURE 703.6.3.12 THE INFORMATION SYMBOL
238 FIGURE 703.6.3.13 STAR OF LIFE
FIGURE 703.6.3.14 ELEVATOR MAIN FLOOR
FIGURE 703.6.3.15 ALARM
239 TABLE 703.7.4 LOW RESOLUTION VMS CHARACTER HEIGHT
TABLE 703.7.5 PIXEL COUNT FOR LOW RESOLUTION VMS SIGNAGE
240 FIGURE 703.7.5 LOW RESOLUTION VMS CHARACTERS
241 704 TELEPHONES
242 FIGURE 704.2.1.1 PARALLEL APPROACH
FIGURE 704.2.1.2 FORWARD APPROACH
244 705 DETECTABLE WARNINGS AND SURFACES
FIGURE 705.5 TRUNCATED DOME SIZE AND SPACING
245 FIGURE 705.6 RAISED RIBBING DETECTABLE SURFACE SIZE AND SPACING
FIGURE 705.6.4 WAYFINDING
706 ASSISTIVE LISTENING SYSTEMS
247 707 INFORMATION TRANSACTION MACHINES
248 FIGURE 707.5 NUMERIC KEY LAYOUT
FIGURE 707.5.1 KEY SIZE
TABLE 707.6.1 TACTILE SYMBOLS
249 708 TWO-WAY COMMUNICATION SYSTEMS
251 FIGURE 708.7 INFORMATION/NAVIGATION/ALERT REFERENCE POINT SYSTEM
FIGURE 708.7.1.2 ACTIVATOR
253 FIGURE 708.8.1 LINKNYC TERMINAL
254 709 SIGNAGE SYSTEM
257 710 PUBLIC INFORMATION DISPLAY TYPES
FIGURE 710.4 MULTISENSORY INFORMATION/EMERGENCY KIOSKS
258 711 DIRECTORIES
259 712 ROOM IDENTIFICATION SYSTEM
713 EMERGENCY SIGNAGE SYSTEM(S)
261 714 WAYFINDING
267 FIGURE 714.18.2 MOBILE APP NAVIGATION
268 FIGURE 714.18.3 VIRTUAL KIOSK
FIGURE 714.18.4 EXAMPLE OF TACTILE MAP
270 FIGURE 714.19.2.1 TACTILE PATH
FIGURE 714.19.2.2 TACTILE ADDRESSES
271 FIGURE 714.19.2.3 IMPLEMENTATION
FIGURE 714.19.3.1 TEXTURED INDICATOR
FIGURE 714.19.3.2 TOP GUIDING EDGE
272 FIGURE 714.19.3.3 BOTTOM GUIDING EDGE
FIGURE 714.19.3.4 SCAFFOLDING
FIGURE 714.19.3.5 SPEAKER/MICROPHONE DEVICE
273 FIGURE 714.19.3.6 ELEVATED PLATFORMS
274 FIGURE 714.20.1 SURFACE GUIDEWAY
275 FIGURE 714.20.2 EMBEDDED GUIDEWAY
FIGURE 714.20.3 SAW CUT GUIDEWAY
276 FIGURE 714.20.4 JUNCTION
278 CHAPTER 8: SELECTED SPACES
800 INTRODUCTION
280 801 GENERAL
802 ASSEMBLY AREAS
281 FIGURE 802.3 WIDTH OF AN INCLUSIVE SPACE IN ASSEMBLY AREAS
FIGURE 802.4 DEPTH OF AN INCLUSIVE SPACE IN ASSEMBLY AREAS
282 FIGURE 802.6.1 ADJUSTABLE HEIGHT INCLUSIVE SPACE
283 FIGURE 802.6.1.1 PORTABLE ADJUSTABLE HEIGHT UNIT
284 FIGURE 802.6.1.1.1 ADJUSTABLE HEIGHT MULTIPLE SEATING PLATFORMS
289 FIGURE 802.9.1.1 INCLUSIVE SPACE ELEVATION
290 TABLE 802.9.2.2 INCLUSIVE SPACE LOCATION ELEVATION OVER STANDING SPECTATORS
TABLE 802.10 INCLUSIVE SPACE DISPERSION
291 803 DRESSING, FITTING, AND LOCKER ROOMS
292 804 KITCHENS AND KITCHENETTES
293 FIGURE 804.2.1 PASS-THROUGH KITCHEN CLEARANCE
FIGURE 804.2.2 U-SHAPED KITCHEN CLEARANCE
295 805 TRANSPORTATION FACILITIES
296 FIGURE 805.3 NYC BUS SHELTER (DOT)10
297 806 HOLDING CELLS AND HOUSING CELLS
298 807 COURTHOUSES
300 808 WAITING AREAS
809 SERVICE AREAS
302 810 DINING AREAS
811 OFFICES
305 FIGURE 811.10.1 TYPE “A” TEMPORARY WORKSPACE EXAMPLE
306 FIGURE 811.10.2 TYPE “B” TEMPORARY WORKSPACE EXAMPLE
812 MEETING ROOMS
308 CHAPTER 9: FURNISHINGS AND EQUIPMENT
900 INTRODUCTION
310 901 GENERAL
902 DINING SURFACES ADN WORK SURFACES
FIGURE 902.3 ADULT DINING AND WORK SURFACES HEIGHT AND WIDTH
312 FIGURE 902.4 HEIGHT OF COUNTERTOP AND TABLETOP SURFACES FOR CHILDREN’S USE, AGES 5 TO 12
FIGURE 902.5 YOUNG CHILDREN’S COUNTERTOP AND TABLETOP SURFACES FOR AGES 5 AND YOUNGER
313 903 SEATING
FIGURE 903 TYPICAL TRANSFER BENCH
314 FIGURE 903.3 ADULT BENCH
318 TABLE 903.9 COMPARISON OF CODE REQUIREMENTS WITH IDG BENCH RECOMMENDATIONS
321 FIGURE 903.23 UNIVERSAL KINETIC FURNITURE EXAMPLE
322 904 SALES AND SERVICE COUNTERS
FIGURE 904.4.2 HEIGHT OF CHECKOUT COUNTERS
905 PRODUCT AND STORAGE FACILITIES
323 906 TRASH AND RECYCLING RECEPTACLES
324 FIGURE 906.4 RECEPTACLE WITH AUTOMATIC OPERATION
907 TYPICAL REFUSE DISPOSAL/STORAGE ROOM
325 FIGURE 907 TYPICAL REFUSE DISPOSAL/STORAGE ROOM
326 908 ALTERNATE REFUSE DISPOSAL/STORAGE ROOM
327 FIGURE 908 ALTERNATE REFUSE DISPOSAL/STORAGE ROOM
328 909 CHARGING STATIONS
910 GAMING MACHINES AND TABLES
330 CHAPTER 10: DWELLING AND SLEEPING UNITS
1000 INTRODUCTION
332 1001 GENERAL
1002 ENTRANCE(S)
FIGURE 1002 ENTRANCE
333 1003 ROUTE
335 FIGURE 1003.6.3 INCLINED HALLWAYS
1004 WALKING SURFACES
336 1005 DOORS AND DOORWAYS
FIGURE 1005 DOORS AND DOORWAYS
1006 RAMPS
1007 ELEVATORS
337 1008 PLATFORMS LIFTS
FIGURE 1008.1.2 ALIGNED CLOSET PLATFORM LIFT CONVERSION
338 1009 OPERABLE PARTS
1010 LAUNDRY AREAS
339 1011 TOILET AND BATHING FACILITIES
340 FIGURE 1011.4.1 HORIZONTAL GRAB BAR REINFORCEMENT LOCATION
341 FIGURE 1011.4.1.1 VERTICAL GRAB BAR REINFORCEMENT LOCATION
FIGURE 1011.4.3 ALTERNATE GRAB BAR EXAMPLE CONFIGURATIONS
345 FIGURE 1011.9 MULTIPURPOSE BATHING COMPARTMENT
349 1012 KITCHENS
FIGURE 1012.1.1 GALLEY KITCHEN CLEARANCE
350 FIGURE 1012.1.2 U-SHAPED KITCHEN CLEARANCE
354 FIGURE 1012.5.1.2 EXAMPLE OF ADAPTABLE LOWER CABINETS
356 FIGURE 1012.6.1.1 ANTI-TIPPING DEVICE (BRACKET)
359 1013 BEDROOMS
360 FIGURE 1013.1.2.2 ADJUSTABLE HEIGHT BEDS
1014 LIVING ROOMS
1015 DINING ROOMS
1016 DENS/MULTIPURPOSE ROOMS
1017 HOME OFFICES
361 1018 BASEMENTS, ATTICS, AND UTILITY ROOMS
1019 INTERIOR BALCONIES AND LOFTS
1020 GARAGE
1021 EXTERIOR BALCONIES AND TERRACES
1022 LANDSCAPE ELEMENTS
363 1023 WINDOWS
364 1024 GENERAL STORAGE AND CLOSETS
1025 COMMUNICATION FEATURES
365 FIGURE 1025.5.2.4 PEEPHOLE HEIGHTS
366 1026 SAFETY SYSTEMS
367 1027 LIGHTING
1028 HVAC
1029 SOUNDPROOFING
1030 AUTOMATIC REMOTE MONITORING
368 1031 VISITABILITY
372 INDEX
]]>
NY NYC IDGSportsandRecreation 2019.pdf ?u=/product/publishers/ny/ny-nyc-idgsportsandrecreation-2019-pdf/ Sat, 19 Oct 2024 13:26:43 +0000 Inclusive Design Guidelines Sports & Recreation New York City
Published By Publication Date Number of Pages
NY 2019 75
]]>
2020 City of Los Angeles amendment pages for integration with the 2019 California Building Code

PDF Catalog

PDF Pages PDF Title
1 INCLUSIVE DESIGN GUIDELINES SPORTS & RECREATION NEW YORK CITY
2 INCLUSIVE DESIGN GUIDELINES SPORTS & RECREATION NEW YORK CITY TITLE PAGE
3 COPYRIGHT
4 THE CITY OF NEW YORK OFFICE OF THE MAYOR
8 FOREWORD
10 CONTENTS
12 LIST OF FIGURES
14 CHAPTER 1: APPLICATION AND ADMINISTRATION
105.3 RESOURCES
106 DEFINITIONS
20 CHAPTER 2: SCOPING
201 GENERAL
203 ADMINISTRATION/DISCLAIMERS
203.1 LIMITATION OF LIABILITY
22 CHAPTER 11: SPORTS AND RECREATIONAL FACILITIES
1100 INTRODUCTION
23 1101 GENERAL
1102 AMUSEMENT RIDES
24 FIGURE 1102.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES
26 1103 RECREATIONAL BOATING FACILITIES
27 FIGURE 1103.3.1(A) BOAT SLIP CLEARANCE
FIGURE 1103.3.1(B) (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
28 FIGURE 1103.3.1(C) (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS
FIGURE 1103.3.2(A) BOARDING PIER CLEARANCE
29 FIGURE 1103.3.2(B) (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
FIGURE 1103.3.2(C) (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS
FIGURE 1103.4 ADAPTIVE BOAT LAUNCH
30 FIGURE 1103.4.1 LOADING BENCH
FIGURE 1103.4.2 ROLL CAGE
1104 EXERCISE MACHINES AND EQUIPMENT
FIGURE 1104.1 WHEELCHAIR WITH CAMBERED WHEELS
31 1105 FISHING PIERS AND PLATFORMS
FIGURE 1105.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
32 1106 GOLF FACILITIES
FIGURE 1106.5 EXAMPLE OF AN ACCESSIBLE GOLF CART
33 1107 MINIATURE GOLF FACILITIES
FIGURE 1107.3.2 GOLF CLUB REACH RANGE AREA
1108 PLAY AREAS
35 TABLE 1108.3.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
38 FIGURE 1108.4.2.1 TRANSFER PLATFORMS
FIGURE 1108.4.2.2 TRANSFER STEPS
40 1109 SWIMMING POOLS, WADING POOLS, HOT TUBS, AND SPAS
FIGURE 1109.2.2 POOL LIFT SEAT LOCATION
41 FIGURE 1109.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 1109.2.4 POOL LIFT SEAT HEIGHT
FIGURE 1109.2.8 POOL LIFT SUBMERGED DEPTH
42 FIGURE 1109.3.2 SLOPED ENTRY SUBMERGED DEPTH
FIGURE 1109.3.3 HANDRAILS FOR SLOPED ENTRY
43 FIGURE 1109.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 1109.4.2 TRANSFER WALL HEIGHT
FIGURE 1109.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
44 FIGURE 1109.4.5 GRAB BARS FOR TRANSFER WALLS
45 FIGURE 1109.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 1109.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM
46 FIGURE 1109.5.4 TRANSFER STEPS
FIGURE 1109.5.6 SIZE OF TRANSFER STEPS
FIGURE 1109.5.7 GRAB BARS
47 1110 SHOOTING FACILITIES WITH FIRING POSITIONS
1111 ICE RINKS
FIGURE 1111.3 TEAM BENCHES
48 1112 ADAPTIVE SPORTS
1112.1 ARCHERY
FIGURE 1112.1.3.1 OUTDOOR ARCHERY FIELD
49 FIGURE 1112.1.3.2 INDOOR ARCHERY FIELD
1112.2 BEEP BALL
FIGURE 1112.2.2 BEEP BALL FIELD
50 FIGURE 1112.2.3 (A) BEEP BALL BASE
FIGURE 1112.2.3(B) BEEP BALL BALL
1112.3 BOCCE
FIGURE 1112.3.2 BOCCE COURT
FIGURE 1112.3.3 BOCCE BALL RAMP
51 1112.4 BOWLING
FIGURE 1112.4.3(A) BOWLING BALL RAMP
FIGURE 1112.4.3(B) BOWLING BALL WITH RETRACTABLE HANDLE
111.2.5 CYCLING
52 FIGURE 1112.5.2 CYCLING TRACK
1112.6. EQUESTRIAN
53 FIGURE 1112.6.3 EQUESTRIAN MOUNTING PLATFORM
54 1112.7 FENCING
1112.8. GOAL BALL
FIGURE 1112.8.2 GOAL BALL FIELD
FIGURE 1112.8.3 GOAL BALL BALL
55 1112.9 JUDO
FIGURE 1112.9.2 JUDO FIELD OF PLAY
1112.10 RUGBY
FIGURE 1112.10.2 RUGBY FIELD
56 1112.11 ACCESSIBLE ROUTES
FIGURE 1112.11.2 SITTING VOLLEYBALL COURT
1112.12 SKIING
57 FIGURE 1112.12.3.1(A) MONO-SKI
FIGURE 1112.12.3.1(B) BI-SKI
58 FIGURE 1112.12.3.2 FOUR-TRACK SKI
FIGURE 1112.12.3.3 THREE-TRACK SKI
FIGURE 1112.12.3.4 TWO-TRACK SKI
59 1112.13 SLED HOCKEY
60 FIGURE 1112.13.2 SLED HOCKEY RINK
61 FIGURE 1112.13.4 PENALTY BOXES
1112.14 TABLE TENNIS
1112.15 TRACK AND FIELD
62 1112.16 WHEELCHAIR BASKETBALL
1112.17 WHEELCHAIR CURLING
63 FIGURE 1112.17.2 WHEELCHAIR CURLING PLAYING FIELD
1112.18 WHEELCHAIR FOOTBALL
64 FIGURE 1112.18.2 WHEELCHAIR FOOTBALL FIELD
65 1112.19 WHEELCHAIR LACROSSE
66 FIGURE 1112.19.2 WHEELCHAIR LACROSSE FIELD
67 1112.20 WHEELCHAIR SOFTBALL
68 FIGURE 1112.20.2 WHEELCHAIR SOFTBALL FIELD
69 FIGURE 1112.20.3(A) BATTERS FRAME, PLAN REVIEW
FIGURE 1112.20.3(B) BATTERS FRAME, ELEVATION VIEW
FIGURE 1112.20.3(C) BATTERS FRAME, PERSPECTIVE VIEW
70 1112.21 WHEELCHAIR TENNIS
72 INDEX
]]>
NY StateEnergyCode 2020 ?u=/product/publishers/ny/ny-stateenergycode-2020/ Sat, 19 Oct 2024 12:57:16 +0000 Energy Conservation Construction Code of New York State
Published By Publication Date Number of Pages
NY 2020 173
]]>
This is a fully integrated custom code based on the 2018 International Energy Conservation Code.

PDF Catalog

PDF Pages PDF Title
1 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE
2 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE TITLE PAGE
3 COPYRIGHT
4 ACKNOWLEDGMENTS
6 PREFACE
8 EFFECTIVE USE OF THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE
12 TABLE OF CONTENTS
14 ECCCNYS—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
16 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
[NY] SECTION C101 SCOPE AND GENERAL REQUIREMENTS
17 [NY] SECTION C102 APPLICABILITY
18 [NY] SECTION C103 INTERPRETATIONS OF ENERGY CODE REQUIREMENTS
19 [NY] SECTION C104 ALTERNATIVE MATERIALS, DESIGNS, METHODS OF CONSTRUCTION AND INSULATING SYSTEMS
SECTION C105 CONSTRUCTION DOCUMENTS
20 [NY] SECTION C106 INSPECTIONS
22 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
30 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
[NY] TABLE C301.1 NEW YORK STATE CLIMATE ZONES BY COUNTY
[NY] TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
31 TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
32 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
33 EQUATION 4-1
EQUATION 4-2
34 [NY] TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD
35 [NY] TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHOD
36 TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
37 EQUATION 4-3
38 TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa
[NY] TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
EQUATION 4-4
39 EQUATION 4-5
41 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
42 SECTION C403 BUILDING MECHANICAL SYSTEMS
43 EQUATION 4-6
EQUATION 4-7
TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY
TABLE C403.3.4 BOILER TURNDOWN
44 TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
45 TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
46 TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
47 TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
48 TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
49 TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
50 TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
51 TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS
52 TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
53 TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT
55 [NY] TABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS
56 [NY] TABLE C403.5(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
[NY] TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
57 TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
60 [NY] TABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
[NY] TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year)
61 TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
62 TABLE C403.8.1(1) FAN POWER LIMITATION
63 TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
64 TABLE C403.8.5.1 COOLING SYSTEMS
66 TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
67 TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
68 TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
69 EQUATION 4-8
70 TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)a,
SECTION C404 SERVICE WATER HEATING (MANDATORY)
72 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
73 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
74 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
76 EQUATION 4-9
78 FIGURE C405.2.3.2 SIDELIT ZONE
FIGURE C405.2.3.3(1) TOPLIT ZONE
79 EQUATION 4-10
FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
80 EQUATION 4-11
81 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
82 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
83 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
84 SECTION C406 ADDITIONAL EFFICIENCY PACKAGES
85 TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
86 TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
87 TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b
88 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
89 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C407 TOTAL BUILDING PERFORMANCE
91 SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
92 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
93 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
94 TABLE C407.5.1(2) HVAC SYSTEMS MAP
95 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
96 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
99 FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST
100 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
101 SECTION C503 ALTERATIONS
102 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
104 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
105 AMCA
ANSI
APSP
ASHRAE
106 ASME
ASTM
107 CRRC
CSA
CTI
DASMA
DOE
108 ICC
IEEE
IES
109 ISO
NEMA
NFPA
NFRC
SMACNA
UL
110 US-FTC
WDMA
112 APPENDIX CA SOLAR-READY ZONE—COMMERCIAL
SECTION CA101 SCOPE
SECTION CA102 GENERAL DEFINITION
SECTION CA103 SOLAR-READY ZONE
114 INDEX
124 ECCCNYS—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
126 CHAPTER 1 [RE] SCOPE AND ADMINISTRATION
[NY] SECTION R101 SCOPE AND GENERAL REQUIREMENTS
127 [NY] SECTION R102 APPLICABILITY
128 [NY] SECTION R103 INTERPRETATIONS OF ENERGY CODE REQUIREMENTS
[NY] SECTION R104 ALTERNATIVE MATERIALS, DESIGNS, METHODS OF CONSTRUCTION AND INSULATING SYSTEMS
129 [NY] SECTION R105 CONSTRUCTION DOCUMENTS
[NY] SECTION R106 INSPECTIONS
132 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
136 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
[NY] TABLE R301.1 NEW YORK STATE CLIMATE ZONES BY COUNTY
[NY] TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
137 TABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
138 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
139 [NY] TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
[NY] TABLE R402.1.4 EQUIVALENT U-FACTORSa
140 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES
143 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
144 SECTION R403 SYSTEMS
146 TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACYa
147 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
148 [NY] TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
149 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
150 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
152 SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
EQUATION 4-1
[NY] TABLE R406.4 MAXIMUM ENERGY RATING INDEX
154 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
SECTION R502 ADDITIONS
155 SECTION R503 ALTERATIONS
SECTION R504 REPAIRS
156 SECTION R505 CHANGE OF OCCUPANCY OR USE
158 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
APSP
ASHRAE
159 ASTM
BOMA
CSA
DASMA
HVI
160 ICC
IEEE
NFPA
161 NFRC
RESNET
UL
US-FTC
WDMA
162 APPENDIX RA SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
SECTION RA101 SCOPE
SECTION RA102 GENERAL DEFINITION
SECTION RA103 SOLAR-READY ZONE
164 INDEX
170 HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR ENERGY CODE
171 ICC EVALUATION SERVICE
172 ICC DIGITAL CODES LIBRARY
173 ICC ASSESSMENT CENTER
]]>