{"id":212013,"date":"2024-10-19T13:43:08","date_gmt":"2024-10-19T13:43:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/fl-floridatestprotocols-2020\/"},"modified":"2024-10-25T06:31:58","modified_gmt":"2024-10-25T06:31:58","slug":"fl-floridatestprotocols-2020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/fl\/fl-floridatestprotocols-2020\/","title":{"rendered":"FL FloridaTestProtocols 2020"},"content":{"rendered":"
The 7th Edition (2020) update to the Florida Building Code:Test Protocols for High Velocity Hurricane Zone updates the 6th Edition 2017 Florida Building Code: Test Protocols for High Velocity Hurricane Zone. Adopted state. Effective Date: December 31, 2020.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | FLORIDA BUILDING CODE – TEST PROTOCOLS FOR HIGH-VELOCITY HURRICANE ZONES SEVENTH EDITION (2020) <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | FLORIDA BUILDING CODE – TEST PROTOCOLS FOR HIGH-VELOCITY HURRICANE ZONES SEVENTH EDITION (2020) TITLE PAGE <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | PREFACE <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 109 <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 109-A DETAIL DRAWINGS DETAIL 1 <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | DETAIL 2 DETAIL 3 <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | DETAIL 4 DETAIL 5 <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | DETAIL 6 DETAIL 7 <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | DETAIL 8 DETAIL 9 <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | DETAIL 10 DETAIL 11 <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 111-20 STANDARD REQUIREMENTS FOR ATTACHMENT OF PERIMETER WOODBLOCKING AND METAL FLASHING TABLE 1 MARGINS OF SAFETY FOR LABORATORY WITHDRAWAL RESISTANCE TESTING <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | TABLE 2 HOOK STRIP\/CONTINUOUS CLEAT THICKNESS REQUIREMENTS FOR EDGE METAL AND COPINGS FACE DIMENSIONS <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | FIGURE 1 DETAIL OF \u201cBUTT-JOINT\u201d METHOD FOR ADJACENT DRIP EDGE\/GRAVEL STOP SECTIONS <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | FIGURE 2 EXAMPLE OF RAISED EDGE AT GRAVEL STOP PERIMETER FLASHING <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | FIGURE 3 EXAMPLE OF A PERIMETER FLASHING FOR CONFIGURATIONS INCLUDING A CONTINUOUS CLEAT FIGURE 4 USE OF HEAVY EXTRUDED GRAVEL STOP WITH HORIZONTAL FLANGE OF LESSER THICKNESS <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | FIGURE 5 EXAMPLE OF REGLET MOUNTED COUNTER-FLASHING <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | FIGURE 6 EXAMPLE OF STUCCO COUNTER-FLASHING <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | FIGURE 7 TYPICAL SILL FLASHING CONFIGURATIONS <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | FIGURE 8 METAL BASE FLASHING CONNECTION WITH VERTICAL WALL <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | FIGURE 9 EXAMPLE OF ADHERED MEMBRANE ROOF SYSTEM ASSEMBLY TERMINATION <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 113 STANDARD REQUIREMENTS FOR JOB SITE MIXING OF ROOF TILE MORTAR <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALT SHINGLE INSTALLATION <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | DETAIL A <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | DETAIL B <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | DETAIL C <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 117-20 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND\/OR BASE SHEETS TO SUBSTRATES <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | FIGURE 5 USE OF STEEL SHEET TO ENSURE SUPPORT OF INSULATION PANEL GAGES <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | TABLE 1 SQUARE FEET PER FASTENER FOR COMMON ANCHOR\/BASE SHEET ATTACHMENT PATTERNS <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | TABLE 2 TYPICAL FASTENER VALUES FOR ARCHITECTURAL APPEARANCE APPLICATIONS TABLE 3 TYPICAL \u2018DYNAMIC PULL THROUGH VALUES\u2019 FOR ARCHITECTURAL APPEARANCE APPLICATIONS <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | FIGURE 1 FASTENER PLACEMENT FOR 2 FOOT BY 4 FOOT BOARDS <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | FIGURE 2 FASTENER PLACEMENT FOR 4 FOOT BY 4 FOOT BOARDS <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | FIGURE 3 FASTENER PLACEMENT FOR 4 FOOT BY 4 FOOT BOARDS <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | FIGURE 4 FASTENER PLACEMENT FOR 4 FOOT BY 8 FOOT BOARDS <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 118-20 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | PART I\u2014GENERAL PART II \u2014MATERIALS <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | PART III\u2014EXECUTION DRAWING 1 TYPICAL 30\/90 HOT MOP <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | DRAWING 2 DRIP EDGE INSTALLATION <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | DRAWING 3 TYPICAL VALLEY INSTALLATION DRAWING 4 VALLEY METAL STRIPPED IN <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | DRAWING 5 WALL FLASHING DETAIL DRAWING 6 WALL FLASHING DETAIL (WALL FLASHING OVER CAP SHEET) <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | DRAWING 7 WALL FLASHING DETAIL (WALL FLASHING OVER CAP SHEET) DRAWING 8 LEAD STACK DETAIL (OVER THE CAP SHEET) <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | DRAWING 9 LEAD STACK DETAIL (OVER THE BASE SHEET) <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | DRAWING 10 EAVE TILE DETAIL (NAIL-ON EPDM EAVE ENCLOSURE) <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | DRAWING 11 EAVE TILE DETAIL (NAIL-ON METAL ENCLOSURE) DRAWING 12 EAVE TILE DETAIL (NAIL-ON ANTIPONDING METAL) <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | DRAWING 13 RIDGE BLOCKING DETAIL <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 119-20 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Horizontal Battens Only \n(Preformed Metals With Edge Returns) <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | PART I\u2014GENERAL PART II\u2014MATERIALS <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | PART III\u2014EXECUTION DRAWING 1 TYPICAL 30\/90 HOT MOP <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | DRAWING 2 DRIP EDGE INSTALLATION <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | DRAWING 3 PERFORMED CLOSED VALLEY (NAIL-ON SYSTEM) DRAWING 4 VALLEY METAL DETAIL (NAIL-ON SYSTEM) DRAWING 5 NAIL-ON VALLEY SYSTEM VALLEY METAL OVER TILE <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | DRAWING 6 WALL FLASHING DETAIL (NAIL-ON SYSTEM) <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | DRAWING 7 PLUMBING STACKS (NAIL-ON SYSTEMS) DRAWING 8 PLUMBING STACKS FLASHING (NAIL-ON SYSTEMS) DRAWING 9 EAVE TILE DETAIL (NAIL-ON EPDM EAVE ENCLOSURE) <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | DRAWING 10 EAVE TILE DETAIL (NAIL-ON METAL EAVE ENCLOSURE) DRAWING 11 EAVE TILE DETAIL (NAIL-ON ANTIPONDING ENCLOSURE) <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | DRAWING 12 HIP RIDGE TILE NAILING DETAIL <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 120-20 MORTAR AND ADHESIVE SET TILE APPLICATION <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | PART I\u2014GENERAL PART II\u2014MATERIALS <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | PART III\u2014EXECUTION <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | DRAWING 1 TYPICAL 30\/90 HOT MAP DRAWING 2 DRIP EDGE INSTALLATION <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | DRAWING 3 TYPICAL VALLEY INSTALLATION DRAWING 4 VALLEY METAL STRIPPED IN <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | DRAWING 5 WALL FLASHING DETAIL (COUNTER FLASHING WITH CAULKED BEAD) DRAWING 6 WALL FLASHING DETAIL (STUCCO STOP DETAIL) <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | DRAWING 7 WALL FLASHING DETAIL (WALL FLASHING OVER CAP SHEET) <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | DRAWING 8 LEAD STACK DETAIL (OVER THE CAPSHEET) DRAWING 9 LEAD STACK DETAIL (OVER THE BASE SHEET) <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | DRAWING 10 EAVE TILE DETAIL EPDM EAVE CLOSURE DRAWING 11 EAVE TILE DETAIL (METAL EAVE ENCLOSURE) DRAWING 12 EAVE TILE DETAIL ANTIPONDING METAL <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | DRAWING 13 MORTAR (ADHESIVE) SET TILE DRAWING 14 BARREL TILE INSTALLATION <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | DRAWING 15 RIDGE BLOCKING DETAIL DETAIL 1 <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | DETAIL 2 DETAIL 3 DETAIL 4 DETAIL 5 <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 127-20 PROCEDURE FOR DETERMINING THE MOMENT OF RESISTANCE AND MINIMUM CHARACTERISTIC RESISTANCE LOAD TO INSTALL A TILE SYSTEM ON A BUILDING OF A SPECIFIED ROOF SLOPE AND HEIGHT USING ALLOWABLE STRESS DESIGN (ASD) IN ACCORDANCE WITH ASCE 7 <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | TABLE 1 \u2014 GABLE ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – \u2265 2:12 to \u2264 4:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cC\u201d TABLE 2 \u2014 GABLE ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 4:12 to \u2264 6:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cC\u201d <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | TABLE 3 \u2014 GABLE ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 6:12 to \u2264 12:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cC\u201d TABLE 4 \u2014 GABLE ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – \u2265 2:12 to \u2264 4:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cD\u201d <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | TABLE 5 \u2014 GABLE ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 4:12 to \u2264 6:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cD\u201d TABLE 6 \u2014 GABLE ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 6:12 to \u2264 12:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cD\u201d <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | TABLE 7 \u2014 HIP ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – \u2265 2:12 to \u2264 4:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cC\u201d TABLE 8 \u2014 HIP ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 4:12 to \u2264 6:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cC\u201d <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | TABLE 9 \u2014 HIP ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 6:12 to \u2264 12:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cC\u201d TABLE 10 \u2014 HIP ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – \u2265 2:12 to \u2264 4:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cD\u201d <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | TABLE 11 \u2014 HIP ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 4:12 to \u2264 6:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cD\u201d TABLE 12 \u2014 HIP ROOFS MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – > 6:12 to \u2264 12:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cD\u201d <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | TABLE 13 WHERE TO OBTAIN INFORMATION <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 128-20 STANDARD PROCEDURE FOR DETERMINING APPLICABLE WIND ALLOWABLE STRESS DESIGN PRESSURES FOR LOW SLOPE ROOF IN ACCORDANCE WITH ASCE 7 TABLE 1 \u2014 MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – \u2264 11\/2:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cC\u201d <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | TABLE 2 \u2014 MINIMUM ASD DESIGN WIND UPLIFT PRESSURES IN PSF FOR ROOF SLOPE – \u2264 11\/2:12 RISK CATEGORY II EXPOSURE CATEGORY \u201cD\u201d <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 130-20 INSTALLATION CRITERIA FOR ROOF SHINGLES AND SHAKES APPLICATION TABLE 1 MAXIMUM EXPOSURE TO WEATHER FOR WOOD SHINGLES AND SHAKES IN INCHES <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | DETAIL A DETAIL B <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | DETAIL C DETAIL D <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURE FOR INSTALLATION OF METAL ROOF SYSTEMS FIGURE 1 EXAMPLE OF PANEL CLEAT <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | FIGURE 2 TYPICAL EAVE TERMINATION DETAIL WITH CLOSURE STRIP <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | FIGURE 3 TYPICAL PROFILES OF RAKE WALL FLASHINGS FIGURE 4 TYPICAL RAKE PROFILES <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | FIGURE 6 TYPICAL CURB FLASHING <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | FIGURE 7A PENETRATION FLASHING FIGURE 7B PENETRATION FLASHING FIGURE 8 ELASTOMERIC FLASHING <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | FIGURE 9 RECOMMENDED STANDING SEAM VALLEY <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | FIGURE 10 RIBBED PANEL VALLEY FIGURE 11 SEALED LOW SLOPE VALLEY LAP <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | FIGURE 12 TRANSITION WITH KNEE BENDS FIGURE 13 TRANSITION FLASHINGS AT HEADWALL CONDITION <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 137 STANDARD REQUIREMENTS FOR MECHANICAL ATTACHMENT OF SINGLE-PLY ROOF COVERINGS TO VARIOUS SUBSTRATES <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | TABLE 1 <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | TABLE 2 MECHANICALLY FASTENED INSULATION FOR BUILDINGS 40 FEET OR LESS IN HEIGHT <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 100-95 TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | FIGURE 1 WIND DRIVEN RAIN TEST FRAME FIGURE 2 WIND DRIVEN RAIN WIND TUNNEL <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 100(A)-95 TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE AND\/OR INCREASED WINDSPEED RESISTANCE OF SOFFIT VENTILATION STRIP AND CONTINUOUS OR INTERMITTENT VENTILATION SYSTEM INSTALLED AT THE RIDGE AREA <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | TABLE 1 WINDSPEED AND WATER SPRAY INTERVALS FOR WIND DRIVEN RAIN RESISTANCE TESTING <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | TABLE 2 WINDSPEED INTERVALS FOR INCREASED WIND RESISTANCE TESTING OF STATIC VENTS, TURBINES1 OR POWERED VENTS <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | TABLE 3 INCREASED WINDSPEED VS. INSTALLATION HEIGHT <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | FIGURE 1A WIND DRIVEN RAIN TEST FRAME, FRONT VIEW FIGURE 1B WIND DRIVEN RAIN TEST FRAME, SIDE VIEW <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | FIGURE 2 WIND DRIVEN RAIN WIND TUNNEL <\/td>\n<\/tr>\n | ||||||
156<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 101-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MORTAR OR ADHESIVE SET TILE SYSTEMS <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | FIGURE 1 STATIC UPLIFT APPARATUS <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 102-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, RIGID ROOF SYSTEMS [For Mechanically Attached, Rigid Roof Systems Accompanied by a Clip, Refer to TAS 102(A)] <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | FIGURE 1 STATIC UPLIFT TEST APPARATUS <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 102(A)-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, CLIPPED, RIGID, ROOF SYSTEMS (For Methods of Mechanical Attachment Excluding Clips, Refer to TAS 102) <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | FIGURE 1 STATIC UPLIFT TEST APPARATUS <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 103-20 TEST PROCEDURE FOR SELF-ADHERED UNDERLAYMENTS FOR USE IN TILE ROOF SYSTEMS <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | TABLE 1 MINIMUM BREAKING STRENGTH VALUES TABLE 2 MINIMUM ELONGATION VALUES (%) <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | TABLE 24.1 TABLE 24.2 <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | FIGURE 1 <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 104-20 TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN TILE ROOF SYSTEMS <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | TABLE 1 MINIMUM BREAKING STRENGTH VALUES (%) TABLE 2 MINIMUM ELONGATION VALUES (%) <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | TABLE 20.1 TABLE 20.2 <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | FIGURE 1 FIGURE 2 <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 105-20 TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | TABLE 1 VALUES FOR T-ESTIMATOR AT 95% PROBABILITY <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | TESTING APPLICATION STANDARD (TAS) 105-20 APPENDIX A FIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORT <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET <\/td>\n<\/tr>\n | ||||||
218<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 106 STANDARD PROCEDURE FOR FIELD VERIFICATION OF THE BONDING OF MORTAR OR ADHESIVE SET TILE SYSTEMS AND MECHANICALLY ATTACHED, RIGID, DISCONTINUOUS ROOF SYSTEMS <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 107-20 TEST PROCEDURE FOR WIND RESISTANCE TESTING OF NON-RIGID, DISCONTINUOUS ROOF SYSTEM ASSEMBLIES (Modified from ASTM D3161) <\/td>\n<\/tr>\n | ||||||
224<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 108-95 TEST PROCEDURE FOR WIND TUNNEL TESTING OF AIR PERMEABLE, RIGID, DISCONTINUOUS ROOF SYSTEMS <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | FIGURE 1 WIND TUNNEL TEST APPARATUS FIGURE 2 WIND TUNNEL TEST APPARATUS (SIDE VIEW) <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 110-2000 TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS AND OTHER ROOFING COMPONENTS TABLE 2(A) TABLE 2(B) <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | TABLE 3 TABLE 4 <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | TABLE 5 TABLE 6 TABLE 7 <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | TABLE 8 TABLE 9 <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | TABLE 10 TABLE 11(A) <\/td>\n<\/tr>\n | ||||||
237<\/td>\n | TABLE 11(B) <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | TABLE 14 TABLE 15 <\/td>\n<\/tr>\n | ||||||
239<\/td>\n | TABLE 17 <\/td>\n<\/tr>\n | ||||||
240<\/td>\n | ASTM <\/td>\n<\/tr>\n | ||||||
242<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 111(A)-95 TEST PROCEDURE FOR ROOF EDGE TERMINATION PERFORMANCE <\/td>\n<\/tr>\n | ||||||
244<\/td>\n | FIGURE 1 MEMBRANE TERMINATION PERFORMANCE TEST CONFIGURATION OPTION TERMINATION FIGURE 2 MEMBRANE TERMINATION PERFORMANCE TEST CONFIGURATION OPTION <\/td>\n<\/tr>\n | ||||||
246<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 111(B)-95 TEST PROCEDURE FOR EDGE METAL PULL-OFF PERFORMANCE <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | FIGURE 1 VIEW OF OUTWARD LOADING OF EDGE METAL VERTICAL FLANGE (UPWARD LOADING OF HORIZONTAL FLANGE ALSO REQUIRED) <\/td>\n<\/tr>\n | ||||||
250<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 111(C)-95 TEST PROCEDURE FOR COPING CAP PULL-OFF PERFORMANCE <\/td>\n<\/tr>\n | ||||||
252<\/td>\n | FIGURE 1 VIEW OF OUTWARD LOADING OF COPING CAP VERTICAL FLANGE (OUTWARD LOADING OF OTHER VERTICAL FLANGE ALSO REQUIRED) FIGURE 2 VIEW OF OUTWARD LOADING OF COPING CAP VERTICAL FLANGE (UPWARD LOAD RESISTANCE) <\/td>\n<\/tr>\n | ||||||
254<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 112-95 STANDARD REQUIREMENTS FOR CONCRETE ROOF TILES <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | TABLE 1 TRANSVERSE BREAKING STRENGTH, MINIMUM LBF (N) TABLE 2 TILE RATINGS AND MAXIMUM WATER ABSORPTION TABLE 3 NUMBER OF TILES TO BE RE-TESTED TABLE 4 RETEST CRITERIA (FAILURE RATE REQUIRED) <\/td>\n<\/tr>\n | ||||||
261<\/td>\n | FIGURE 1 TRANSVERSE STRENGTH TEST APPARATUS FIGURE 2 PERMEABILITY TEST APPARATUS <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | TESTING APPLICATION STANDARD (TAS) No. 112-95 APPENDIX A CLARIFICATION OF TESTING FREQUENCY AND SAMPLING METHOD <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 TEST PROCEDURES FOR ROOFING ASSEMBLIES IN THE HIGH-VELOCITY HURRICANE ZONE JURISDICTION TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | 1. SCOPE 2. REFERENCED DOCUMENTS <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | 3. TERMINOLOGY & UNITS 4. SIGNIFICANCE OF USE <\/td>\n<\/tr>\n | ||||||
268<\/td>\n | 5. GENERAL INFORMATION 6. APPLICABLE DOCUMENTS AND GLOSSARY <\/td>\n<\/tr>\n | ||||||
270<\/td>\n | 7. GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
271<\/td>\n | 8. PERFORMANCE REQUIREMENTS AND TESTS <\/td>\n<\/tr>\n | ||||||
276<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 APPENDIX A TEST PROCEDURE FOR ABOVE DECK COMBUSTIBILITY ASTM E108 <\/td>\n<\/tr>\n | ||||||
278<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 APPENDIX B TEST PROCEDURE FOR SIMULATED DYNAMIC UPLIFT PRESSURE RESISTANCE OF MECHANICALLY ATTACHED ROOFING ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
280<\/td>\n | TABLE B1 DYNAMIC PRESSURE GUST INTERVALS <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | FIGURE B1 DYNAMIC UPLIFT TEST APPARATUS <\/td>\n<\/tr>\n | ||||||
282<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-95 APPENDIX C TEST PROCEDURE FOR SIMULATED UPLIFT PRESSURE RESISTANCE OF ROOFING ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
283<\/td>\n | TABLE C1 UPLIFT PRESSURE INTERVALS <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | FIGURE C1 UPLIFT PRESSURE TEST APPARATUS FIGURE C2 UPLIFT PRESSURE TEST SPECIMEN MOUNTED IN TEST <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 APPENDIX D TEST PROCEDURE FOR SIMULATED UPLIFT PRESSURE RESISTANCE OF ADHERED ROOFING ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
287<\/td>\n | APPARATUS TABLE D1 UPLIFT LOAD INTERVALS AND CORRESPONDING PRESSURES <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 APPENDIX E TEST PROCEDURE FOR CORROSION RESISTANCE OF FASTENERS, BATTEN BARS AND STRESS DISTRIBUTION PLATES <\/td>\n<\/tr>\n | ||||||
292<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 APPENDIX F TEST PROCEDURE FOR SUSCEPTIBILITY TO HAIL DAMAGE FOR ROOFING SYSTEMS <\/td>\n<\/tr>\n | ||||||
294<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 APPENDIX G TEST PROCEDURE FOR SUSCEPTIBILITY TO LEAKAGE FOR ROOFING SYSTEMS <\/td>\n<\/tr>\n | ||||||
296<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-95 APPENDIX H TEST PROCEDURES FOR SMALL SCALE QC AND PHYSICAL PROPERTIES OF APPROVED ROOFING SYSTEMS <\/td>\n<\/tr>\n | ||||||
298<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-95 APPENDIX I TEST PROCEDURE FOR STATIC AND DYNAMIC PUNCTURE RESISTANCE OF ROOFING ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
303<\/td>\n | FIGURE I1 STATIC PUNCTURE TEST APPARATUS FIGURE I2 DYNAMIC PUNCTURE TEST APPARATUS <\/td>\n<\/tr>\n | ||||||
304<\/td>\n | FIGURE I3 TYPICAL DYNAMIC PUNCTURE HEAD <\/td>\n<\/tr>\n | ||||||
306<\/td>\n | TESTING APPLICATION STANDARD (TAS) 114-11 APPENDIX J TEST PROCEDURE FOR 12 FOOT BY 24 FOOT SIMULATED UPLIFT PRESSURE RESISTANCE OF ROOFING ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
308<\/td>\n | TABLE J112 FOOT BY 24 FOOT UPLIFT PRESSURE INTERVALS <\/td>\n<\/tr>\n | ||||||
310<\/td>\n | TESTING APPLICATION STANDARD (TAS) 116-95 TEST PROCEDURE FOR AIR PERMEABILITY TESTING OF RIGID, DISCONTINUOUS ROOF SYSTEMS <\/td>\n<\/tr>\n | ||||||
313<\/td>\n | TABLE 1 NUMBER OF COURSES AND NUMBER OF COMPONENTS PER COURSE <\/td>\n<\/tr>\n | ||||||
315<\/td>\n | FIGURE 1 AIR PERMEABILITY TEST APPARATUS <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | TESTING APPLICATION STANDARD (TAS) 117(A)-95 TEST PROCEDURE FOR WITHDRAWAL RESISTANCE TESTING OF MECHANICAL FASTENERS USED IN ROOF SYSTEM ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
320<\/td>\n | TESTING APPLICATION STANDARD (TAS) 117(B)-95 TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES <\/td>\n<\/tr>\n | ||||||
323<\/td>\n | FIGURE 1 HOLDING DEVICE CONFIGURATION FIGURE 2 HOLDING DEVICE CONFIGURATION FOR LAPPED TEST SPECIMENS <\/td>\n<\/tr>\n | ||||||
324<\/td>\n | FIGURE 3 HOLDING DEVICE CONFIGURATION FOR ROOFING OR CAP NAIL TESTING FIGURE 4 VIEW OF DYNAMIC PULL-THROUGH TESTING <\/td>\n<\/tr>\n | ||||||
326<\/td>\n | TESTING APPLICATION STANDARD (TAS) 117(C)-95 TEST PROCEDURE FOR DYNAMIC PULL-OFF PERFORMANCE OF ROOFING FASTENER HEADS OR FASTENERS WITH BEARING PLATES <\/td>\n<\/tr>\n | ||||||
328<\/td>\n | TABLE 1 FASTENER ASSEMBLY PULL-OFF VALUES VS. DROP HEIGHT <\/td>\n<\/tr>\n | ||||||
329<\/td>\n | FIGURE 1 DIAGRAM OF DYNAMIC PULL-OFF TEST APPARATUS <\/td>\n<\/tr>\n | ||||||
330<\/td>\n | FIGURE 2 DIAGRAM OF WIRE REINFORCED TEST STRAP FIGURE 3 PHOTOGRAPH OF TYPICAL WIRE REINFORCED TEST STRAP <\/td>\n<\/tr>\n | ||||||
331<\/td>\n | FIGURE 4 PHOTOGRAPH OF DYNAMIC PULL-OFF TESTING FIGURE 5 PHOTOGRAPH OF DYNAMIC PULL-OFF TESTING <\/td>\n<\/tr>\n | ||||||
332<\/td>\n | TESTING APPLICATION STANDARD (TAS) 121-95 STANDARD REQUIREMENTS FOR TESTING AND APPROVAL OF ROOFING ADHESIVES, MASTICS AND COATINGS <\/td>\n<\/tr>\n | ||||||
334<\/td>\n | TESTING APPLICATION STANDARD (TAS) 123-95 STANDARD REQUIREMENTS FOR MORTAR USED IN MORTAR SET TILE SYSTEMS <\/td>\n<\/tr>\n | ||||||
336<\/td>\n | TESTING APPLICATION STANDARD (TAS) 123-95 APPENDIX A STANDARD REQUIREMENTS OF TILE ADHESIVE USED TO REPAIR OR SUPPLEMENT TILE ATTACHMENT <\/td>\n<\/tr>\n | ||||||
337<\/td>\n | TABLE 1 TILE ADHESIVE COMPOSITION REQUIREMENTS TABLE 2 TILE ADHESIVE ADHESION REQUIREMENTS TABLE 3 TILE ADHESIVE TENSILE\/ELONGATION REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
338<\/td>\n | TABLE 4 SHORE ‘A’ HARDNESS REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
340<\/td>\n | TESTING APPLICATION STANDARD (TAS) 124-20 TEST PROCEDURE FOR FIELD UPLIFT RESISTANCE OF EXISTING MEMBRANE ROOF SYSTEMS AND IN SITU TESTING FOR REROOF AND NEW CONSTRUCTION APPLICATIONS <\/td>\n<\/tr>\n | ||||||
342<\/td>\n | FIGURE 1 SCREW AND EYE-BOLT LOCATIONS FIGURE 2 ALTERNATE LOAD TRANSFER DEVICE <\/td>\n<\/tr>\n | ||||||
343<\/td>\n | TABLE 1 NUMBER OF BELL CHAMBER OR BONDED PULL TESTS TO BE CONDUCTED PER ROOF AREA <\/td>\n<\/tr>\n | ||||||
345<\/td>\n | TABLE 2 APPLIED LOAD INCREMENTS <\/td>\n<\/tr>\n | ||||||
348<\/td>\n | TESTING APPLICATION STANDARD (TAS) 124-20 BELL CHAMBER TEST RESULTS <\/td>\n<\/tr>\n | ||||||
352<\/td>\n | ROOF SYSTEM INFORMATION – DETAIL #1 <\/td>\n<\/tr>\n | ||||||
353<\/td>\n | BUILDING INFORMATION – DETAIL #2 <\/td>\n<\/tr>\n | ||||||
354<\/td>\n | ROOF SYSTEM INFORMATION – DETAIL #3 <\/td>\n<\/tr>\n | ||||||
356<\/td>\n | TESTING APPLICATION STANDARD (TAS) 124-20 BONDED PULL TEST RESULTS <\/td>\n<\/tr>\n | ||||||
360<\/td>\n | ROOF SYSTEM INFORMATION – DETAIL #1 <\/td>\n<\/tr>\n | ||||||
361<\/td>\n | BUILDING INFORMATION – DETAIL #2 <\/td>\n<\/tr>\n | ||||||
362<\/td>\n | ROOF SYSTEM INFORMATION – DETAIL #3 <\/td>\n<\/tr>\n | ||||||
364<\/td>\n | TESTING APPLICATION STANDARD (TAS) 125-03 STANDARD REQUIREMENTS FOR METAL ROOFING SYSTEMS <\/td>\n<\/tr>\n | ||||||
368<\/td>\n | FIGURE 8-1 ASSEMBLED UPLIFT TEST APPARATUS FOR UL 580 <\/td>\n<\/tr>\n | ||||||
371<\/td>\n | TABLE T125-1 TEST PRESSURES <\/td>\n<\/tr>\n | ||||||
382<\/td>\n | FIGURE 9-1 SCHEMATIC OF TEST APPARATUS FOR ASTM E1592 UPLIFT TESTING <\/td>\n<\/tr>\n | ||||||
383<\/td>\n | FIGURE 9-2 EXAMPLES OF STRUCTURAL ELEMENTS AND PANEL WIDTH FOR DIFFERENT PROFILES FIGURE 9-3 IMPROPER SEAL WHERE FILM SPANS CREVICE AT BASE OF RIB FIGURE 9-4 PLEATS MAKE CONTACT WITH METAL PANEL ON BOTH SIDES OF CLIPS FIGURE 9-5 PROPER SEAL AT RIB WITH MULTIPLE LONGITUDINAL AIR BAGS FIGURE 9-6 IMPROPER USE OF MULTIPLE AIR BAGS BETWEEN SUPPORT <\/td>\n<\/tr>\n | ||||||
384<\/td>\n | TESTING APPLICATION STANDARD (TAS) 126-95 STANDARD PROCEDURES FOR ROOF MOISTURE SURVEYS <\/td>\n<\/tr>\n | ||||||
392<\/td>\n | TESTING APPLICATION STANDARD (TAS) 131-20 STANDARD REQUIREMENTS FOR UNREINFORCED THERMOPLASTIC OLEFIN ELASTOMER BASED SHEET USED IN SINGLE-PLY ROOF SYSTEMS <\/td>\n<\/tr>\n | ||||||
394<\/td>\n | TABLE 1 PHYSICAL REQUIREMENTS FOR UNREINFORCED TPO ELASTOMER SHEETS <\/td>\n<\/tr>\n | ||||||
396<\/td>\n | TESTING APPLICATION STANDARD (TAS) 132-95 STANDARD REQUIREMENTS FOR TESTING AND APPROVAL OF SEALANTS USED IN ROOFING <\/td>\n<\/tr>\n | ||||||
397<\/td>\n | PHYSICAL PROPERTY REQUIREMENTS PERFORMANCE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
398<\/td>\n | TESTING APPLICATION STANDARD (TAS) 135-95 STANDARD REQUIREMENTS FOR FIBERGLASS REINFORCED TILE, SHINGLES OR PANELS AND FIBER CEMENT SHINGLES, SHAKES OR PANELS <\/td>\n<\/tr>\n | ||||||
399<\/td>\n | TABLE 1 PHYSICAL PROPERTY REQUIREMENTS FOR FIBERGLASS REINFORCED, COMPOSITE TILE, SHINGLES OR PANELS <\/td>\n<\/tr>\n | ||||||
404<\/td>\n | TABLE 2 PHYSICAL PROPERTY REQUIREMENTS FOR FIBER CEMENT SHINGLES, SHAKES OR PANELS <\/td>\n<\/tr>\n | ||||||
406<\/td>\n | TESTING APPLICATION STANDARD (TAS) 138-95 STANDARD REQUIREMENTS FOR ALUMINUM PIGMENTED EMULSIFIED ASPHALT USED AS A PROTECTIVE COATING FOR ROOFING <\/td>\n<\/tr>\n | ||||||
410<\/td>\n | TESTING APPLICATION STANDARD (TAS) 139-95 STANDARD REQUIREMENTS FOR WHITE ROOF PATCH SPECIFICATION <\/td>\n<\/tr>\n | ||||||
414<\/td>\n | TESTING APPLICATION STANDARD (TAS) 140-95 STANDARD REQUIREMENTS FOR NONFIBERED ROOF AND FOUNDATION COATINGS <\/td>\n<\/tr>\n | ||||||
416<\/td>\n | TESTING APPLICATION STANDARD (TAS) 141-95 STANDARD REQUIREMENTS FOR COAL TAR (CUTBACK) ROOF COATING, BRUSHING CONSISTENCY <\/td>\n<\/tr>\n | ||||||
420<\/td>\n | TESTING APPLICATION STANDARD (TAS) 142-95 STANDARD REQUIREMENTS FOR COAL TAR ROOF CEMENT, ASBESTOS FREE <\/td>\n<\/tr>\n | ||||||
422<\/td>\n | TESTING APPLICATION STANDARD (TAS) 143-95 STANDARD REQUIREMENTS FOR WHITE ELASTOMERIC ROOF COATINGS USED FOR COATING BUILT UP ROOFS AND METAL ROOFING SYSTEMS <\/td>\n<\/tr>\n | ||||||
428<\/td>\n | TESTING APPLICATION STANDARD (TAS) 201-94 IMPACT TEST PROCEDURES <\/td>\n<\/tr>\n | ||||||
429<\/td>\n | FIGURE 1 THREE (3) BASIC STORM PANEL ATTACHMENTS FOR TESTING <\/td>\n<\/tr>\n | ||||||
434<\/td>\n | TESTING APPLICATION STANDARD (TAS) 202-94 CRITERIA FOR TESTING IMPACT & NONIMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE <\/td>\n<\/tr>\n | ||||||
435<\/td>\n | FIGURE 1 THREE (3) BASIC STORM PANEL ATTACHMENTS FOR TESTING <\/td>\n<\/tr>\n | ||||||
440<\/td>\n | TESTING APPLICATION STANDARD (TAS) 203-94 CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING <\/td>\n<\/tr>\n | ||||||
441<\/td>\n | FIGURE 1 THREE (3) BASIC STORM PANEL ATTACHMENTS FOR TESTING <\/td>\n<\/tr>\n | ||||||
444<\/td>\n | TESTING APPLICATION STANDARD (TAS) 301-94 TESTING LABORATORY <\/td>\n<\/tr>\n | ||||||
448<\/td>\n | TOP TOOLS FOR STRUCTURAL DESIGN <\/td>\n<\/tr>\n | ||||||
449<\/td>\n | ICC EVALUATION SERVICE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Florida Building Code -Test Protocols for High Velocity Hurricane Zone, Seventh Edition<\/b><\/p>\n |