{"id":214588,"date":"2024-10-19T13:54:30","date_gmt":"2024-10-19T13:54:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-66912015a12016\/"},"modified":"2024-10-25T06:53:34","modified_gmt":"2024-10-25T06:53:34","slug":"bsi-pd-66912015a12016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-66912015a12016\/","title":{"rendered":"BSI PD 6691:2015+A1:2016"},"content":{"rendered":"
This Published Document gives guidance on the use of BS EN 13108-1:2006, BS EN 13108-2:2008, BS EN 13108-4:2006, BS EN 13108-5:2006, BS EN 13108-7:2006, BS EN 13108-8:2005, BS EN 13108-20:2006 and BS EN 13108-21:2016 .<\/p>\n
Clause 1<\/b> to Clause 10<\/b> of this Published Document give general guidance and background information on BS EN 13108.<\/p>\n
Annex A gives guidance on the importance of BS EN 13108 mixture specifications. Annex B contains an example specification which gives the UK choice for specifying asphalt concrete in accordance with BS EN 13108-1. Annex C contains an example specification which gives the UK choice for specifying hot rolled asphalt in accordance with BS EN 13108-4. Annex D contains an example specification which gives the UK choice for specifying stone mastic asphalt in accordance with BS EN 13108-5.<\/p>\n
This Published Document does not give guidance on BS EN 13108-6 as this standard is either rarely used in the UK or covered by other guidance.<\/p>\n
This Published Document is applicable to mixtures for use on roads and other paved areas, including airfields. Detailed provisions for airfields are specified elsewhere.<\/p>\n
\nNOTE 1 For airfield installations on the defence estate, guidance is given in the Defence Infrastructure Organisation Practitioner\u2019s Guide 06\/11 [2].<\/i><\/p>\n
NOTE 2 There are several asphalt mixtures in general use which have not been covered by British Standards but which are now covered in BS EN 13108. These are stone mastic asphalt, covered by BS EN 13108-5, and asphalt concrete for very thin layers (thin surfacing), covered by BS EN 13108-2.<\/i><\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 33<\/td>\n \tTable\u00a01\tReferences to protocols in BS\u00a0594987:2015 <\/td>\n<\/tr>\n \n 34<\/td>\n Table\u00a02\u2003\ufffdType\u2011testing sample preparation and testing requirements for UK asphalt concrete mixtures conforming to BS\u00a0EN\u00a013108\u20111 <\/td>\n<\/tr>\n \n 35<\/td>\n Table\u00a03\u2003\ufffdType-testing sample preparation and testing requirements for UK HRA mixtures conforming to\u00a0BS\u00a0EN\u00a013108\u20114 <\/td>\n<\/tr>\n \n 36<\/td>\n Table\u00a04\u2003Type-\u00a0testing sample preparation and testing requirements for UK SMA\u00a0mixtures conforming to BS\u00a0EN\u00a013108\u20115 <\/td>\n<\/tr>\n \n 40<\/td>\n \tTable\u00a05\tPermitted mean deviations from target (extracted from \uea01BS\u00a0EN\u00a013108\u201121:2016\uea02, Table\u00a0A.1)
\tTable\u00a06\tDetermination of operating compliance level of plant for single results (extracted from \uea01BS\u00a0EN\u00a013108\u201121:2016, Table\u00a0A.3\uea02) <\/td>\n<\/tr>\n\n 41<\/td>\n \tTable\u00a07\tMinimum frequency for analysis of finished product (tonnes\/test) (extracted from \uea01BS\u00a0EN\u00a013108\u201121:2016, Table\u00a0A.4\uea02) <\/td>\n<\/tr>\n \n 42<\/td>\n \uea01Table\u00a08\u2003\ufffdTolerances to be applied to the declared target grading and binder content (extracted from BS\u00a0EN\u00a013108\u201121:2016, Table\u00a0A.1) <\/td>\n<\/tr>\n \n 43<\/td>\n Table\u00a09\u2003Example of a declared specification AC\u00a032\u00a0HDM base\u00a040\/60\u00a0rec <\/td>\n<\/tr>\n \n 44<\/td>\n Table 10\u2003Example of a declared specification AC\u00a06\u00a0dense surf\u00a0160\/220\u00a0PSV\u00a060 <\/td>\n<\/tr>\n \n 45<\/td>\n \uea01Table\u00a011\u2003Example of a declared specification HRA\u00a035\/14F surf\u00a040\/60\u00a0des
\tTable\u00a012\tNext harder grades for recovered binder assessment <\/td>\n<\/tr>\n\n 46<\/td>\n Figure B.1\u2003\ufffdExample specification giving the UK choice for specifying asphalt concrete in accordance with\u00a0BS\u00a0EN\u00a013108\u20111
\tTable\u00a0A.1\tImportance of mixture specifications <\/td>\n<\/tr>\n\n 52<\/td>\n \tTable\u00a0B.1\tAggregate grading target limits for\u00a032\u00a0mm designed dense\/HDM\/HMB base mixtures (AC\u00a032\u00a0dense\/HDM\/HMB base XX\/YY des)
\tTable\u00a0B.2\tBinder grades for design base and binder course mixtures
\tTable\u00a0B.3\tMinimum target binder content for designed dense base mixtures <\/td>\n<\/tr>\n\n 53<\/td>\n Table\u00a0B.4\u2003Limiting wheel tracking requirements for site classifications <\/td>\n<\/tr>\n \n 54<\/td>\n \tTable\u00a0B.5\tAggregate grading target limits for\u00a032\u00a0mm designed dense\/HDM\/HMB binder course mixtures (AC\u00a032\u00a0dense\/HDM\/HMB bin XX\/YY des)
\tTable\u00a0B.6\tAggregate grading target limits for\u00a020\u00a0mm designed dense\/HDM\/HMB binder course mixtures (AC\u00a020\u00a0dense\/HDM\/HMB bin XX\/YY des) <\/td>\n<\/tr>\n\n 55<\/td>\n \tTable\u00a0B.7\tMinimum target binder content for designed binder course mixtures <\/td>\n<\/tr>\n \n 56<\/td>\n \tTable\u00a0B.8\tAggregate grading target limits for\u00a020\u00a0mm,\u00a014\u00a0mm and\u00a010\u00a0mm EME2\u00a0mixtures (AC\u00a020\/14\/10\u00a0EME2\u00a0base\/bin XX\/YY des)
\tTable\u00a0B.9\tMinimum target binder content, Bact
\tTable\u00a0B.10\tNumber of gyrations <\/td>\n<\/tr>\n\n 58<\/td>\n Table\u00a0B.11\u2003\ufffdTarget limits for composition for recipe dense base and binder course mixtures (AC D dense\/HDM base\/bin XX\/YY rec) <\/td>\n<\/tr>\n \n 59<\/td>\n \tTable\u00a0B.12\tTarget limits for composition for open graded binder course mixtures [AC D open bin XX\/YY (grav)] <\/td>\n<\/tr>\n \n 60<\/td>\n \tTable\u00a0B.13\tTarget limits for composition for open graded surface course mixtures (AC\u00a014\u00a0or\u00a010\u00a0open surf XX\/YY) <\/td>\n<\/tr>\n \n 61<\/td>\n \tTable\u00a0B.14\tTarget limits for composition for close graded surface course mixtures (AC\u00a014\u00a0or\u00a010\u00a0close surf XX\/YY) <\/td>\n<\/tr>\n \n 62<\/td>\n Table\u00a0B.15\u2003Target limits for composition for dense, medium graded and fine graded surface course mixtures (AC D dense\/med\/fine surf XX\/YY) <\/td>\n<\/tr>\n \n 63<\/td>\n \tTable\u00a0B.16\tGuidance on selection of binder grades
\tTable\u00a0B.17\tMaximum temperature of the mixture <\/td>\n<\/tr>\n\n 64<\/td>\n \tTable\u00a0B.18\tAggregate grading target limits for\u00a014\u00a0mm and\u00a010\u00a0mm BBA mixtures (AC\u00a014\u00a0or\u00a010\u00a0BBA C bin XX\/YY des)
Table\u00a0B.19\u2003\ufffdAggregate grading target limits for\u00a014\u00a0mm and\u00a010\u00a0mm BBA mixtures (AC\u00a014\u00a0or\u00a010\u00a0BBA C\/D surf XX\/YY des)
\tTable\u00a0B.20\tMinimum target binder content, Bact <\/td>\n<\/tr>\n\n 65<\/td>\n \tTable\u00a0B.21\tNumber of gyrations and percentage of air voids
\tTable\u00a0B.22\tProportional rut depth, P, at\u00a060 \u00b0C and\u00a010\u2009000\u00a0cycles <\/td>\n<\/tr>\n\n 66<\/td>\n \tTable\u00a0B.23\tStiffness modulus at\u00a015 \u00b0C
\tTable\u00a0B.24\tAcceptable strain in fatigue <\/td>\n<\/tr>\n\n 67<\/td>\n Figure\u00a0C.1\u2003\ufffdExample specification giving the UK choice for specifying HRA in accordance with BS\u00a0EN\u00a013108\u20114
\tTable\u00a0B.25\tMaximum temperature of the mixture <\/td>\n<\/tr>\n\n 70<\/td>\n Table\u00a0C.1\u2003Limits for target composition for base and binder course mixtures <\/td>\n<\/tr>\n \n 72<\/td>\n Table C.2A\u2003\ufffdLimits for target composition for surface course mixtures, Type F mixtures\u2009A) \u2013 Design and recipe target aggregate gradings (HRA %\/D F surf XX\/YY des\/rec) <\/td>\n<\/tr>\n \n 73<\/td>\n Table C.2B\u2003\ufffdLimits for target composition for surface course mixtures, Type F recipe mixtures\u2009A) \u2013 target binder content (HRA %\/D F surf XX\/YY rec) <\/td>\n<\/tr>\n \n 74<\/td>\n Table C.2C\u2003\ufffdLimits for target composition for surface course mixtures, Type C mixtures \u2013 Design target aggregate gradings (HRA %\/D C surf\u00a0XX\/YY des) <\/td>\n<\/tr>\n \n 76<\/td>\n Table\u00a0C.3\u2003Limiting wheel tracking requirements for site classifications
\tTable\u00a0C.4\tMaximum temperature of the mixture <\/td>\n<\/tr>\n\n 78<\/td>\n \tTable\u00a0C.5\tCompliance grading of chippings <\/td>\n<\/tr>\n \n 79<\/td>\n Figure\u00a0D.1\u2003Example specification giving the UK choice for specifying SMA\u00a0in accordance with BS\u00a0EN\u00a013108\u20115 <\/td>\n<\/tr>\n \n 82<\/td>\n \tTable\u00a0D.1\tLimits for target composition for SMA\u00a0mixtures <\/td>\n<\/tr>\n \n 83<\/td>\n \tTable\u00a0D.2\tLimiting wheel tracking recommendations for site classifications <\/td>\n<\/tr>\n \n 84<\/td>\n \tTable\u00a0D.3\tMaximum temperature of the mixture <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Guidance on the use of BS EN 13108, Bituminous mixtures. Material specifications<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2016<\/td>\n 88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":214593,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1301,2641],"product_tag":[],"class_list":{"0":"post-214588","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-93-080-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/214588","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/214593"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=214588"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=214588"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=214588"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}