{"id":225759,"date":"2024-10-19T14:40:14","date_gmt":"2024-10-19T14:40:14","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-606622012\/"},"modified":"2024-10-25T08:33:08","modified_gmt":"2024-10-25T08:33:08","slug":"bs-en-606622012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-606622012\/","title":{"rendered":"BS EN 60662:2012"},"content":{"rendered":"
IEC 60662:2011 specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes which comply with the safety requirements of IEC 62035. This second edition cancels and replaces the first edition published in 1980 and its amendments. It constitues a technical revision. Main items that required development of the 2nd edition of IEC 60662 are: – restriction to performance requirements. Safety requirements are given in IEC 62035: Discharge lamps (excluding fluorescent lamps) – Safety specifications; – introduction of a test device for ignition; – split of the lamp data sheets which make use of the test device and those which do not; – provisions for measurement during starting, measurement of electrical and photometrical characteristics and tests for lumen maintenance and life; – general review e.g. of maximum lamp outlines and alignment of data; – new order of data sheets by wattage.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English \n CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4 General lamp requirements <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5 Marking 6 Dimensions 7 Caps 8 Test requirements for lamp starting, warm-up, electrical and photometric characteristics <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 9 Information for ballast and ignitor design <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 10 Information for luminaire design <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 11 Maximum lamp outlines 12 Numbering system for lamp data sheets <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Annex A(normative) \nWaveshape of voltage pulses for lamp starting test (schematic drawings) Figures \n Figure A.1 \u2013 Waveshape: positive pulse during positive half cycle Figure A.2 \u2013 Waveshape: positive pulse during negative half cycle <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Figure A.3 \u2013 Shape and parameters of the pulse used in North America <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Annex B(informative) \nDiagrammatic data sheets for location of lamp dimensions <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Annex C(normative) \nGuidance for determining quadrilateral diagrams <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure C.1 \u2013 Relationship of wattage and voltage of an HPS lamp Figure C.2 \u2013 Lamp characteristic curves for several HPS lamps Figure C.3 \u2013 Typical ballast characteristic curves Figure C.4 \u2013 Typical lag or reactor ballast characteristic curves at different supply voltages <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure C.5 \u2013 Minimum and maximum wattage lines <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Figure C.6 \u2013 Finished quadrilateral relative to the referenceballast curves and drop-out locus <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex D(normative) \nMeasurement of voltage increase at lamp terminals for luminaire design <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex E(informative) \nHPS lamp drop-out voltage measurement procedure <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Figure E.1 \u2013 Example of test circuit <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Figure E.2 \u2013 Typical quadrilateral diagram showing drop-out points <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure E.3 \u2013 Example plot of 400 W HPS lamp ballast curves showing drop-out points <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure E.4 \u2013 Incorrect drop-out point measurement due to raising lamp voltage at too high a rate Figure E.5 \u2013 Test for lamp-ballast equilibrium <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex F(normative) Fixed settings of the ignition device (see 8.2.1) \nand requirements for ignition Table F.1 \u2013 Fixed settings of the ignition device (see 8.2.1) <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex G(normative) \nMethod of measuring electrical and photometrical characteristics <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Figure G.1 \u2013 Circuit diagram for measurement of lamp characteristics <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Annex H(normative) \nMethod of test for lumen maintenance and life <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Annex I(informative) \nMaximum lamp outlines Table I.1 \u2013 List of data sheets for maximum lamp outlines <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex J(normative) \nLamp data sheets <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" High-pressure sodium vapour lamps. Performance specifications<\/b><\/p>\n |