{"id":245514,"date":"2024-10-19T16:08:53","date_gmt":"2024-10-19T16:08:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61158-3-122019-tc\/"},"modified":"2024-10-25T11:09:07","modified_gmt":"2024-10-25T11:09:07","slug":"bs-en-iec-61158-3-122019-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61158-3-122019-tc\/","title":{"rendered":"BS EN IEC 61158-3-12:2019 – TC"},"content":{"rendered":"

IEC 61158-3-12:2019 defines the services provided to the Type 12 fieldbus application layer at the boundary between the application and data-link layers of the fieldbus reference model and systems management at the boundary between the data-link layer and systems management of the fieldbus reference model. This fourth edition cancels and replaces the third edition published in 2014. It constitutes a technical revision. The main changes are: lt;br \/gt;- Technical corrections in the communication services lt;br \/gt;- Editorial improvements for clarification.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\ncompares BS EN IEC 61158-3-12:2019 <\/td>\n<\/tr>\n
2<\/td>\nTRACKED CHANGES
Text example 1 \u2014 indicates added text (in green) <\/td>\n<\/tr>\n
49<\/td>\nundefined <\/td>\n<\/tr>\n
52<\/td>\nAnnex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
54<\/td>\nCONTENTS <\/td>\n<\/tr>\n
57<\/td>\nFOREWORD <\/td>\n<\/tr>\n
59<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
60<\/td>\n1 Scope
1.1 General
1.2 Specifications
1.3 Conformance <\/td>\n<\/tr>\n
61<\/td>\n2 Normative references
3 Terms, definitions, symbols, abbreviations and conventions
3.1 Reference model terms and definitions <\/td>\n<\/tr>\n
62<\/td>\n3.2 Service convention terms and definitions <\/td>\n<\/tr>\n
63<\/td>\n3.3 Data-link service terms and definitions <\/td>\n<\/tr>\n
66<\/td>\n3.4 Symbols and abbreviations <\/td>\n<\/tr>\n
68<\/td>\n3.5 Common conventions <\/td>\n<\/tr>\n
69<\/td>\n4 Data-link layer services and concepts
4.1 Operating principle
4.2 Topology <\/td>\n<\/tr>\n
70<\/td>\n4.3 Data-link layer overview
Figures
Figure 1 \u2013 Mapping of logical data in an Ethernet frameconsisting of a single Type 12 DLPDU <\/td>\n<\/tr>\n
71<\/td>\n4.4 Error detection overview
4.5 Parameter and process data handling introduction
4.6 Node reference model
4.6.1 Mapping onto OSI Basic Reference Model <\/td>\n<\/tr>\n
72<\/td>\n4.6.2 Data-link layer features
4.7 Operation overview
4.7.1 Relation to ISO\/IEC\/IEEE 88023
4.7.2 Type 12 modes
Figure 2 \u2013 Type 12 data-link reference model <\/td>\n<\/tr>\n
73<\/td>\n4.7.3 Logical topology
Figure 3 \u2013 Type 12 segments in open mode
Figure 4 \u2013 Type 12 segment in direct mode <\/td>\n<\/tr>\n
74<\/td>\n4.8 Addressing
4.8.1 Addressing overview
4.8.2 Segment addressing
4.8.3 Device addressing
Figure 5 \u2013 Addressing mode overview <\/td>\n<\/tr>\n
75<\/td>\n4.8.4 Logical addressing
4.8.5 FMMU introduction
Figure 6 \u2013 Fieldbus memory management unit overview <\/td>\n<\/tr>\n
76<\/td>\n4.8.6 Sync manager introduction
4.9 Slave classification
4.9.1 Full slave
4.9.2 Basic slave
4.10 Structure of the communication layer in the slave <\/td>\n<\/tr>\n
77<\/td>\nFigure 7 \u2013 Layering of communication <\/td>\n<\/tr>\n
78<\/td>\n5 Communication services
5.1 Overview
5.2 Read services
5.2.1 Overview
5.2.2 Positional physical read (APRD)
Figure 8 \u2013 Flow of Type 12 service primitives <\/td>\n<\/tr>\n
79<\/td>\n5.2.3 Configured-address physical read (FPRD)
Tables
Table 1 \u2013 Auto-increment physical read (APRD)
Table 2 \u2013 Configured-address physical read (FPRD) <\/td>\n<\/tr>\n
80<\/td>\n5.2.4 Broadcast read (BRD)
5.2.5 Logical read (LRD)
Table 3 \u2013 Broadcast read (BRD) <\/td>\n<\/tr>\n
81<\/td>\n5.3 Write services
5.3.1 Overview
5.3.2 Positional physical write (APWR)
Table 4 \u2013 Logical read (LRD)
Table 5 \u2013 Auto-increment physical write (APWR) <\/td>\n<\/tr>\n
82<\/td>\n5.3.3 Configured-address physical write (FPWR)
5.3.4 Broadcast write (BWR)
Table 6 \u2013 Configured-address physical write (FPWR) <\/td>\n<\/tr>\n
83<\/td>\n5.3.5 Logical write (LWR)
Table 7 \u2013 Broadcast write (BWR)
Table 8 \u2013 Logical write (LWR) <\/td>\n<\/tr>\n
84<\/td>\n5.4 Combined read\/write services
5.4.1 Overview
5.4.2 Positional physical read\/write (APRW)
5.4.3 Configured-address physical read\/write (FPRW)
Table 9 \u2013 Auto-increment physical read\/write (APRW) <\/td>\n<\/tr>\n
85<\/td>\n5.4.4 Broadcast read\/write (BRW)
Table 10 \u2013 Configured-address physical read\/write (FPRW)
Table 11 \u2013 Broadcast read\/write (BRW) <\/td>\n<\/tr>\n
86<\/td>\n5.4.5 Logical read\/write (LRW)
5.4.6 Positional physical read \/ multiple write (ARMW)
Table 12 \u2013 Logical read\/write (LRW)
Table 13 \u2013 Auto-increment physical read \/ multiple write (ARMW) <\/td>\n<\/tr>\n
87<\/td>\n5.4.7 Configured-address physical read \/ multiple write (FRMW)
5.5 Network services
5.5.1 Overview
Table 14 \u2013 Configured-address physical read \/ multiple write (FRMW) <\/td>\n<\/tr>\n
88<\/td>\n5.5.2 Publish network variables (PNV)
5.6 Mailbox
5.6.1 Overview
Table 15 \u2013 Publisher network variable (PNV) <\/td>\n<\/tr>\n
89<\/td>\nFigure 9 \u2013 Successful mailbox write sequence <\/td>\n<\/tr>\n
90<\/td>\n5.6.2 Mailbox data transmission services
Figure 10 \u2013 Successful mailbox read sequence
Table 16 \u2013 Mailbox write <\/td>\n<\/tr>\n
91<\/td>\nTable 17 \u2013 Mailbox read update <\/td>\n<\/tr>\n
92<\/td>\nTable 18 \u2013 Mailbox read <\/td>\n<\/tr>\n
93<\/td>\n6 Local interactions
6.1 Read local
6.2 Write local
Table 19 \u2013 Read local
Table 20 \u2013 Write local <\/td>\n<\/tr>\n
94<\/td>\n6.3 Event local
Table 21 \u2013 Event local <\/td>\n<\/tr>\n
95<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Tracked Changes. Industrial communication networks. Fieldbus specifications – Data-link layer service definition. Type 12 elements<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n97<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":245519,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-245514","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/245514","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/245519"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=245514"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=245514"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=245514"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}