{"id":339965,"date":"2024-10-19T23:48:42","date_gmt":"2024-10-19T23:48:42","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-10349-132002\/"},"modified":"2024-10-25T22:57:45","modified_gmt":"2024-10-25T22:57:45","slug":"bs-iso-10349-132002","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-10349-132002\/","title":{"rendered":"BS ISO 10349-13:2002"},"content":{"rendered":"
This part of ISO 10349 specifies a general test method for the determination of pH of solutions of photographic-grade chemicals to within \u00b1 0,1 pH units.<\/p>\n
This method is not intended to monitor the pH of formulated solutions used directly in photographic processing, e.g. developers.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | TitlePage – Photography\ufffd\u2014 Photographic-grade chemicals\ufffd\u2014 Test methods\ufffd\u2014 <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | TableofContent – Contents Page <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Foreword – Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Scope – 1\ufffd\ufffd\ufffd Scope NormativeReference – 2\ufffd\ufffd\ufffd Normative reference Clause1 – 4\ufffd\ufffd\ufffd Hazards Clause1 – 5\ufffd\ufffd\ufffd Reagents UntitledSubclause2 – 5.1\ufffd\ufffd\ufffd Calibration buffers UntitledSubclause3 – 5.1.1\ufffd\ufffd\ufffd pH\ufffd4,0 buffer solution <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | UntitledSubclause3 – 5.1.2\ufffd\ufffd\ufffd pH\ufffd7,0 buffer solution UntitledSubclause3 – 5.1.3\ufffd\ufffd\ufffd pH\ufffd10,0 buffer solution Clause1 – 6\ufffd\ufffd\ufffd Apparatus UntitledSubclause2 – 6.1\ufffd\ufffd\ufffd pH meter UntitledSubclause2 – 6.2\ufffd\ufffd\ufffd Electrodes UntitledSubclause2 – 6.3\ufffd\ufffd\ufffd Constant temperature water-bath Clause1 – 7\ufffd\ufffd\ufffd Sampling Clause1 – 8\ufffd\ufffd\ufffd Procedure Subclause2 – 8.1\ufffd\ufffd\ufffd Calibration and standardization UntitledSubclause3 – 8.1.1\ufffd\ufffd\ufffd Consult the manufacturer’s instruction manual for proper set-up and… UntitledSubclause3 – 8.1.2\ufffd\ufffd\ufffd Rinse the electrodes ( <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | UntitledSubclause3 – 8.1.3\ufffd\ufffd\ufffd Rinse the electrodes with water and blot dry. UntitledSubclause3 – 8.1.4\ufffd\ufffd\ufffd Rinse the electrodes with water; blot dry and proceed with sample m… UntitledSubclause3 – 8.1.5\ufffd\ufffd\ufffd Calibration of the pH meter shall be done just prior to sample meas… UntitledSubclause3 – 8.1.6\ufffd\ufffd\ufffd Calibration buffers ( Subclause2 – 8.2\ufffd\ufffd\ufffd pH measurement UntitledSubclause3 – 8.2.1\ufffd\ufffd\ufffd After temperature equilibration and calibration of the pH meter for… UntitledSubclause3 – 8.2.2\ufffd\ufffd\ufffd Weigh the test portion specified in the appropriate International S… UntitledSubclause3 – 8.2.3\ufffd\ufffd\ufffd Rinse the electrodes with water and blot dry. Immerse the electrode… UntitledSubclause3 – 8.2.4\ufffd\ufffd\ufffd Record the pH of the solution to the nearest 0,1\ufffdpH units. Clause1 – 9\ufffd\ufffd\ufffd Test report <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | AnnexInformative – Electrode care Clause1 – A.1\ufffd\ufffd\ufffd Storage Clause1 – A.2\ufffd\ufffd\ufffd pH electrodes\ufffd\u2014 Preconditioning\/rejuvenation Clause1 – A.3\ufffd\ufffd\ufffd Reference electrode\ufffd\u2014 Care\/rejuvenation Subclause2 – A.3.1\ufffd\ufffd\ufffd Calomel reference electrode Subclause2 – A.3.2\ufffd\ufffd\ufffd Silver\/silver chloride electrodes <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Photography. Photographic-grade chemicals. Test methods – Determination of pH<\/b><\/p>\n |