{"id":363381,"date":"2024-10-20T01:45:19","date_gmt":"2024-10-20T01:45:19","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-bpvc-vi-2013\/"},"modified":"2024-10-26T02:45:05","modified_gmt":"2024-10-26T02:45:05","slug":"asme-bpvc-vi-2013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-bpvc-vi-2013\/","title":{"rendered":"ASME BPVC VI 2013"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
49<\/td>\n | 2.02A-1 Horizontal Return Tube, Brick\u2010Set 2.02A-2 Gas Flow Patterns of Scotch\u2010Type Boilers <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 2.02A-3 Type C Firebox Boiler 2.02A-4 Three\u2010Pass Firebox Boiler <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 2.02A-5 Locomotive Firebox Boiler 2.02A-6 Vertical Firetube Boiler <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 2.03A Horizontal Sectional Cast Iron Boiler 2.03B Vertical Sectional Cast Iron Boiler 2.04A Modules Connected With Parallel Piping 2.04B Modules Connected With Primary\u2010Secondary Piping <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 3.01 Official Certification Mark <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 3.01A Safety Valve <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 3.01B Safety Relief Valve 3.02A Float Type Low\u2010Water Cutoff <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 3.02B Electric Probe Type Low\u2010Water Control <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 3.03-1 Thermostatic Trap 3.03-2 Float Trap 3.03-3 Float and Thermostatic Trap 3.03-4 Bucket Trap With Trap Closed <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 3.05 Typical Return Loop <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 3.11 Pressure Gages <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 3.20 Minimum Pounds of Steam Per Hour Per Square Foot of Heating Surface (kg\/h\/m2) <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | 3.20I Safety Relief Valve Discharge Pipe <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 3.30-1 Single Hot Water Heating Boiler \u2014 Acceptable Piping Installation <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 3.30-2 Hot Water Heating Boilers in Battery \u2014 Acceptable Piping Installation <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 3.30-3 Single Steam Boilers \u2014 Acceptable Piping Installation <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | 3.30-4A Steam Boilers in Battery \u2014 Pumped Return \u2014 Acceptable Piping Installation <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | 3.30-4B Steam Boilers in Battery \u2014 Gravity Return \u2014 Acceptable Piping Installation <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 3.31C-1 Expansion Tank Capacities for Gravity Hot Water Systems <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 3.31C-2 Expansion Tank Capacities for Forced Hot Water Systems 3.33 Size of Bottom Blowoff Piping, Valves, and Cocks <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | 5.01A Atmospheric Gas Burner <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | 5.01C Combination Fuel Burners 5.02A High\u2010Pressure Atomizing Burner <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | 5.02D Horizontal Rotary Cup Fuel Oil Burner <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | 5.03-1 Underfeed Single\u2010Retort Stoker 5.03-2 Overthrow Reciprocating Plate-Feed-Type Spreader Stoker <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | 5.03-3 Chain Grate Stoker With Section Showing Links <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | I.01-1 Exhibit A <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | I.02-1 Exhibit B <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | III-1 Standard Units for Use in Equations <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME BPVC – VI -2013 BPVC Section VI, Recommended Rules for the Care and Operation of Heating Boilers<\/b><\/p>\n |