{"id":67330,"date":"2024-10-17T13:22:43","date_gmt":"2024-10-17T13:22:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d6226-2005\/"},"modified":"2024-10-24T18:35:17","modified_gmt":"2024-10-24T18:35:17","slug":"astm-d6226-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d6226-2005\/","title":{"rendered":"ASTM-D6226 2005"},"content":{"rendered":"<\/p>\n
1.1 This test method covers cellular plastics, which are composed of membranes or walls of polymer separating small cavities or cells. These cells may be interconnecting (open cell), non-connecting (closed cell), or any combination of these types. This test method determines numerical values for open cells. It is a porosity determination, measuring the accessible cellular volume of a material. The remaining volume is that occupied by closed cells and cell walls. Since any conveniently sized specimen can only be obtained by some cutting operation, a fraction of the closed cells will be opened by specimen preparation and will be included as open cells, (see Note 2).<\/p>\n
1.2 This test method provides good accuracy on predominantly highly open-celled materials. By not accounting for closed cells that were opened during specimen preparation, the accuracy decreases as the closed cell content increases and as the cell size increases.<\/p>\n
1.3 The values as stated in SI units are to be regarded as the standard. The values in brackets are given for reference only.<\/p>\n
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n
Note 1This test method and ISO 4590-1981 use the same basic principles but are significantly different in experimental detail.<\/p>\n
Note 2Two procedures for correcting for cells opened during specimen preparation are described in Appendix X1.1.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Terminology Summary of Test Method <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Significance and Use Apparatus Sampling and Test Specimen Preparation Conditioning FIG. 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Procedure Calculation Report <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Precision and Bias Keywords A1. PRINCIPLE OF OPERATION OF THE GAS PYCNOMETER A1.1 A1.2 TABLE 1 FIG. A1.1 <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | A1.3 A2. THEORY FOR CALIBRATING THE PYCNOMETER A2.1 A2.2 A2.3 A2.4 A2.5 A3. CALIBRATING THE PYCNOMETER A3.1 A3.2 A3.3 A3.4 A3.5 <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | A3.6 A3.7 FIG. A3.1 <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | X1. CORRECTING FOR CELLS OPENED DURING SPECIMEN PREPARATION X1.1 X1.2 Procedure 1\u2014Determination of Open Cell Content Using Cell Dimensions to Correct for Cells Opened During Specimen Preparation X1.3 Procedure 2\u2014Determination of Open Cell Content, Correction for Cells Opened During Specimen Preparation by Recutting Each Cube Into Eight Smaller Pieces FIG. X1.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" D6226-05 Standard Test Method for Open Cell Content of Rigid Cellular Plastics<\/b><\/p>\n |