{"id":70243,"date":"2024-10-17T14:18:22","date_gmt":"2024-10-17T14:18:22","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d7619\/"},"modified":"2024-10-24T18:50:17","modified_gmt":"2024-10-24T18:50:17","slug":"astm-d7619","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d7619\/","title":{"rendered":"ASTM-D7619"},"content":{"rendered":"

ASTM D7619-10<\/h3>\n

Historical Standard: Standard Test Method for Sizing and Counting Particles in Light and Middle Distillate Fuels, by Automatic Particle Counter<\/h4>\n
\n

ASTM D7619<\/h4>\n

Scope<\/strong><\/p>\n

1.1 This test method uses a specific automatic particle counter (APC) to count and measure the size of dispersed dirt particles, water droplets and other particles, in light and middle distillate fuel, and bio fuels such as biodiesel and biodiesel blends, in the overall range from 4 \u00b5<\/span>m(c) to 100 \u00b5<\/span>m(c) and in the size bands \u2265<\/span>4 \u00b5<\/span>m(c), \u2265<\/span>6 \u00b5<\/span>m(c), and \u2265<\/span>14 \u00b5<\/span>m(c).<\/p>\n

Note<\/span> 1\u2014ASTM specification fuels falling within the scope of this test method include Specifications: D975 grades 1D and 2D, D3699, D4814 (see 14.1.1.1), D6751, D6985, D7467 and distillate grades of D396 and D2880.<\/p>\n

Note<\/span> 2\u2014For the purposes of this test method, water droplets are counted as particles, and agglomerated particles are detected and counted as a single larger particle. Dirt includes biological particles. Although the projected area of a particle is measured, this is expressed as the diameter of a sphere for the purposes of this test method.<\/p>\n

Note<\/span> 3\u2014The notation (c), used with particle sizes, is used to denote that the apparatus has been calibrated in accordance with ISO 11171. Strictly this only applies to particles up to 50 \u00b5<\/span>m.<\/p>\n

Note<\/span> 4\u2014This test method may be used for particle sizes bands up to 100 \u00b5<\/span>m(c), however the precision has only been determined for the size bands \u2265<\/span>4 \u00b5<\/span>m(c), \u2265<\/span>6 \u00b5<\/span>m(c), and \u2265<\/span>14 \u00b5<\/span>m(c).<\/p>\n

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n

Keywords<\/strong><\/p>\n

automatic particle counting; automotive diesel; biodiesel; fuel cleanliness; gas oil; gasoline; kerosine; marine diesel; Light distillates; Middle distillate fuels; Automatic particle counters; Distillate fuels<\/p>\n

ICS Code<\/strong><\/p>\n

ICS Number Code 75.160.20 (Liquid fuels)<\/p>\n

DOI:<\/strong> 10.1520\/D7619-10<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents <\/td>\n<\/tr>\n
2<\/td>\nTerminology
Summary of Test Method
Significance and Use
Apparatus <\/td>\n<\/tr>\n
3<\/td>\nReagents and Materials
Sampling
Preparation of Apparatus
Test Specimen Preparation <\/td>\n<\/tr>\n
4<\/td>\nProcedure
Report
TABLE 1 <\/td>\n<\/tr>\n
5<\/td>\nPrecision and Bias
Keywords
TABLE 2 <\/td>\n<\/tr>\n
6<\/td>\nA1. AUTOMATIC PARTICLE COUNTING APPARATUS (APC)
A1.1 General
A1.2 Automatic Changeover Valve
A1.3 Double Pump
A1.4 Laser
A1.5 Test Specimen Delivery Tube Assembly
A1.6 Calibration Software
A1.7 Pre-Measurement Checks
FIG. A1.1 <\/td>\n<\/tr>\n
7<\/td>\nX1. TABULAR AND GRAPHICAL REPRESENTATION OF PRECISION
TABLE X1.1
FIG. X1.1
TABLE X1.2 <\/td>\n<\/tr>\n
8<\/td>\nFIG. X1.2
TABLE X1.3 <\/td>\n<\/tr>\n
9<\/td>\nFIG. X1.3 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D7619-10 Standard Test Method for Sizing and Counting Particles in Light and Middle Distillate Fuels, by Automatic Particle Counter <\/a><\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2010<\/td>\n9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":70244,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1074,2637],"product_tag":[],"class_list":{"0":"post-70243","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-75-160-20","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/70243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/70244"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=70243"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=70243"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=70243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}