{"id":8598,"date":"2024-10-16T19:31:36","date_gmt":"2024-10-16T19:31:36","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-f1038\/"},"modified":"2024-10-24T11:04:06","modified_gmt":"2024-10-24T11:04:06","slug":"astm-f1038","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-f1038\/","title":{"rendered":"ASTM-F1038"},"content":{"rendered":"<\/p>\n
1.1 This test method is limited to evaluation of canister, hand-held, stick, and utility type vacuum cleaners without a driven agitator.<\/p>\n
1.2 This test method provides a test to determine operating life of the motor, before servicing is needed, by an accelerated laboratory procedure. The motor is tested while mounted and is operated in a vacuum cleaner.<\/p>\n
1.3 The values as stated in inch-pound units are to be regarded as the standard. The values in parentheses are given for information only.<\/p>\n
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Terminology Significance and Use Apparatus and Materials <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Sampling Procedures for Motor Life Evaluation TABLE 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Precision and Bias Keywords A1. METHOD FOR DETERMINING 40 % DEGRADATION OF PERFORMANCE A1.1 A1.2 Derivation A1.3 Terms A2. CORRECTION OF DATA TO STANDARD CONDITIONS A2.1 Air Density Ratio A2.2 Corrected Suction <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" F1038-02(2006) Standard Test Method for Motor Life Evaluation of a Canister, Hand-held, Stick, and Utility Type Vacuum Cleaner Without a Driven Agitator<\/b><\/p>\n |